• 제목/요약/키워드: Relative control

검색결과 3,716건 처리시간 0.032초

The Impairment of Thyroid Hormones Homeostasis after Short-Term Exposure to Di(2-ethylhexyl)phthalate in Adolescent Male Rats

  • Kim, Sang-Yon;Hong, Yeon-Pyo;Yang, Yun-Jung
    • 한국발생생물학회지:발생과생식
    • /
    • 제25권4호
    • /
    • pp.293-298
    • /
    • 2021
  • Di(2-ethylhexyl)phthalate (DEHP) could induce metabolic disorders through interfering with thyroid homeostasis. Therefore, we evaluated the effects of short term to environmental relevant doses of DEHP on thyroid hormones. Four week old Sprague-Dawley (SD) rats were treated with vehicle (corn oil), and DEHP 0.75, 7.5, and 150 mg/kg/day. The rats were treated with once daily by oral gavage and were sacrificed with after 1 week. They were measured body weight and relative thyroid weight, serum thyroid hormones and histological changes of thyroid. There was no difference in body weight between the control and DEHP exposed rats. Relative thyroid weight in DEHP 150 mg/kg/day treated group was significantly lower than control. Serum thyroxine levels was decreased in rats exposed to 0.75 and 150 mg/kg/day DEHP. No histological changes were observed in the thyroid of rats administered DEHP compared to control. Exposure to DEHP at environmental relevant levels, even short-term exposure, can cause hypothyroidism in adolescent rats even the exposure period is relative short.

온실 포그 냉방 제어시스템 개발 및 냉방효과 (Development of Fog Cooling Control System and Cooling Effect in Greenhouse)

  • 박석호;문종필;김진구;김승희
    • 생물환경조절학회지
    • /
    • 제29권3호
    • /
    • pp.265-276
    • /
    • 2020
  • 본 연구는 여름철 고온기에 작물을 정상적으로 재배할 수 있는 환경을 조성하여 농산 가격이 가장 높은 여름철에 수확량을 높이고 재배기간을 연장시켜 농가소득을 올릴 수 있는 방안을 제시하고자 수행하였다. 바닥면적 504㎡의 연동온실의 최대 냉방부하는 462,609W로 나타났으며, 고온기에 온실을 차광하지 않고도 32℃ 이하로 유지하기 위해서는 시간당 472L의 물을 포그 분무해야 하는 것으로 나타났다. 포그 냉방 시스템은 포그 장치, 유동팬, 차광장치로 구성하고, 이들 장치를 효과적으로 제어할 수 있는 포그 냉방 자동제어장치를 개발하였다. 포그 냉방시스템의 냉방 성능은 온실 외기온 보다 내부온도를 6℃ 낮출 수 있는 것으로 나타났다. 포그 온실의 내부 상대습도는 주간에는 40~80%로 대조 온실의 20~60% 보다 약 20% 높게 나타나 오이의 생육에 기여하는 것으로 나타났다. 오이의 생육상태는 포그 온실에서 재배한 오이가 대조 온실에 비해 초장, 엽장, 엽폭, 엽수, 엽록소 값이 전체적으로 높게 나타났다. 포그 온실의 오이 수확량은 대조 온실에 비해 단동 온실에서는 1.8배, 연동 온실에서는 2배 높게 나타났다.

간헐공조 전시관내 유물 진열장의 온·습도 환경 분석 (Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning)

  • 이선명;임보아;김서진
    • 보존과학회지
    • /
    • 제29권4호
    • /
    • pp.311-320
    • /
    • 2013
  • 조사 대상인 유물 진열장은 온도 변화에 대응한 조온기능이 미약한 반면 조습 능력이 비교적 높았다. 유물 진열장 내부의 연평균 온 습도는 $18.8^{\circ}C$, 60.3% 로 전시실에 비해 온도는 낮고 습도는 높은 분포를 나타냈다. 또한 온도는 계절변화에 따라 변동률이 높은 반면 습도는 계절별 평균값이 59~61%로 일정하게 유지되었다. 여름철에는 전시실과 마찬가지로 고온고습 분포를 나타냈고 공조기 가동에 따른 온도의 하강은 습도를 상승시켰으며. 겨울철에는 공조기 가동에 따라 전시실과 유물 진열장 간 온 습도의 차이가 커져 수분 문제가 제기되었다. 유물 진열장 내부 온 습도에 대한 PI는 18.0%로 전시물 보존을 위한 적정 온 습도 조성률이 매우 저조하였다. 특히 여름철과 겨울철은 PI가 1% 미만으로 진열장 내 철저한 온습도 관리가 필요할 것으로 판단된다.

다층 퍼셉트론 기반 고해상도 위성영상의 상대 방사보정 (Relative Radiometric Normalization for High-Spatial Resolution Satellite Imagery Based on Multilayer Perceptron)

  • 서대교;어양담
    • 한국측량학회지
    • /
    • 제36권6호
    • /
    • pp.515-523
    • /
    • 2018
  • 다중시기의 위성영상에 대해 일관성 있는 변화탐지 결과를 획득하기 위해서는 전처리 과정이 필수적으로 이루어져야 한다. 특히, 분광값과 관련된 전처리 과정은 방사보정으로 수행될 수 있으며, 일반적으로 상대 방사보정이 활용되고 있다. 하지만, 대부분의 상대 방사보정은 두 영상간의 관계를 선형으로 가정하며, 생태학적 차이와 같은 비선형적인 분광특성은 고려되지 않는다. 따라서, 본 연구에서는 방사 및 생태학적 특성에 대한 복합적인 보정을 수행할 수 있는 비선형적인 관계를 가정한 상대 방사보정을 제안하였다. 제안된 방법은 입력영상 및 참조영상을 선정하고, no-change method를 통해 radiometric control set samples를 추출하였다. 또한, 충분한 정보를 고려하기 위하여 화소값뿐만 아니라 분광지수들이 추출되었고, 비선형적인 관계의 모델링은 다층 퍼셉트론을 통해 수행되었다. 최종적으로 기존의 상대 방사보정기법과 비교 분석을 수행하였고, 시각적 및 정략적으로 평가한 결과 제안된 방법이 기존의 상대 방사보정보다 우수한 것을 확인하였다.

Pole Assignment for Structural Active Control

  • Vongchavalitkul, Sanguan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.5-7
    • /
    • 2004
  • Significant progress has been achieved in the active control of civil-engineering structures, not only in the control algorithm, but also in control testing of the scaled model and full-scale building. At the present time, most algorithms used in the active control of civil engineering structures are based on the various active control techniques. In this paper represents active control method, by using pole assignment for reducing structural vibration under excited load. Numerical simulations are performed to assess the effectiveness of pole assignment control system. The relative displacement of structure system is significantly reduced.

  • PDF

Quantitative and Pattern Recognition Analyses for the Quality Evaluationof Herba Epimedii by HPLC

  • Nurul Islam, M.;Lee, Sang-Kyu;Jeong, Seo-Young;Kim, Dong-Hyun;Jin, Chang-Bae;Yoo, Hye-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.137-144
    • /
    • 2009
  • In this study, quantitative and pattern recognition analyses for the quality evaluation of Herba Epimedii using HPLC was developed. For quantitative analysis, five major bioactive constituents, hyperin, epimedin A, epimedin B, epimedin C, and icariin were determined. Analysis was carried out on Capcell pak $C_{18}$ column ($250{\time}4.6$ mm, 5 ${\mu}m$) with a mobile phase of mixture of acetonitrile and 0.1% formic acid, using UV detection at 270 nm. The linear behavior was observed over the investigated concentration range (2-50 ${\mu}g/mL;\;r_2\;>$ 0.99) for all analytes. The intraand inter-day precisions were lower than 4.3% (as a relative standard deviation, RSD) and accuracies between 95.1% and 104.4%. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of one reference sample. The RSD of intra- and inter-day variation of relative retention time (RRT) and relative peak area (RPA) of the 12 selected common peaks were below 0.8% and 4.7%, respectively. The developed methods were applied to analysis of twenty Herba Epimedii extract samples. Contents of hyperin, epimedin A, epimedin B, epimedin C, and icariin were calculated to be 0$\sim$0.79, 0.69$\sim$1.91, 0.93$\sim$9.58, 0.65$\sim$3.05, and 2.43$\sim$11.8 mg/g dried plant. Principal component analysis (PCA) showed that most samples were clustered together with the reference samples but several apart from the main cluster in the PC score plot, indicating differences in overall chemical composition between two clusters. The present study suggests that quantitative determination of marker compounds combined with pattern-recognition method can provide a comprehensive approach for the quality assessment of herbal medicines.

Effects of Microwave Pretreatment on Mesophilic Anaerobic Digestion for Mixture of Primary and Secondary Sludges Compared with Thermal Pretreatment

  • Park, Woon-Ji;Ahn, Johng-Hwa
    • Environmental Engineering Research
    • /
    • 제16권2호
    • /
    • pp.103-109
    • /
    • 2011
  • This work experimentally determined the effect of thermal and microwave pretreatments on the anaerobic digestion of mixtures of municipal primary and secondary sludges in semi-continuous mesophilic digesters at hydraulic retention times (HRT) of 20, 15, 10, 7, and 5 days. The ratio of soluble chemical oxygen demand (COD) to total COD in thermally pretreated and microwaved sludges at $80^{\circ}C$ was 2.7 and 3.2 times higher than that of raw sludge, respectively. The volatile solids (VS) and COD removal efficiencies in all three digesters fed with raw (control), thermally pretreated (TM), and microwaved (MW) sludges decreased as the HRT was reduced. The highest relative improvement in VS removal compared to the control occurred at the HRT of 5 days in the TM and MW (29 and 41% higher than the control, respectively). At this HRT, improvement in the COD removal efficiencies in the TM and MW compared to the control was 28 and 53%, respectively. Improvements in biogas production compared with the control increased in both the TM and MW as the HRT was reduced to 5 days. The relative improvement in daily biogas production compared to the control from the TM and MW was 33 and 53% higher than the control at the HRT of 5 days, respectively. The results show that microwave pretreatment is more effective than thermal pretreatment in increasing the solubilization degree and mesophilic anaerobic biodegradability of sewage sludge.

동절기 대향류형 환기장치의 온실 내 습도 조절 효과 분석 (Analysis on the Effect of Greenhouse Humidity Control by Counter-flow Ventilator in Winter)

  • 이태석;강금춘;장재경;백이;임류갑
    • 생물환경조절학회지
    • /
    • 제29권3호
    • /
    • pp.259-264
    • /
    • 2020
  • 본 연구에서는 겨울철 보온으로 인해 야간 및 새벽에 상대습도가 높아지는 온실에 대향류형 환기장치를 설치하고 그 효과를 분석하였다. 대향류형 환기장치는 크기 0.96×0.65×0.82(W×D×H, m)의 케이스에 크기 0.54×0.40×0.75(W×D×H, m)의 PE소재의 열교환 소자와 급기와 배기를 위한 송풍팬(풍량 6,800㎥/h, 소비전력1.7kW) 2대가 내부에 있다. 환기장치는 총 2대를 이용하였으며 토마토의 적정 생육 환경을 고려하여 설정 습도를 80%하고 18시부터 익일 8시까지 온실 내 온도 및 습도를 측정하고 분석하였다. 관행 온실에서 야간 평균 온도 및 습도는 14.9℃, 82.8%, 시험구 온실에서 야간 평균 온습도는 15.1℃, 79.9%로 측정되어 온도는 0.1℃, 습도는 약 3% 차이가 났다. 온실 평균 온도 및 습도를 월별로 비교하고 독립표본 t검정을 통해 분석해 본 결과, 유의수준 1%에서 각 월의 온도는 차이가 없는 것으로 나타났으며 습도는 차이가 있다고 판단된다. 따라서 대향류형 환기장치의 사용이 온실의 습도를 관리하고 작물 생육에 적합환 환경을 조성하여 작물 생산성 향상에 도움을 줄 수 있다고 판단된다. 이 외에도 환기장치 사용에 따른 난방비 증가와 같은 손실적 요소와 이익적 요소를 복합적으로 고려한 추가적인 연구도 필요할 것으로 사료된다.