• Title/Summary/Keyword: Rejuvenation heat treatment

Search Result 3, Processing Time 0.02 seconds

Rejuvenation Technologies for Hot Gas Path Components made of Nickel Based Superalloys (니켈기 초합금 소재 고온부 부품의 재생정비기술)

  • Kang, Sin-Ho;Choi, Heui-Sook;Kim, Dae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.424-429
    • /
    • 2003
  • Hot gas path components, which are made of nickel based superalloys, are subject to periodic replacement due to degradation of thermomechanical properties that might bring catastrophic failure during normal operation of gas turbine units. In order to rejuvenate the metallurgical condition of the serviced components, heat treating techniques such as solution annealing and aging heat treatments have widely been employed. However, the effectiveness of those typical heat treatments is not apparent enough in terms of quantitative grounds. On the other hand the demand of the rejuvenation heat treatment and hot isostatic pressing (HIP) have constantly been raised by the end users. Therefore it is necessary to verify how the typical heat treating techniques affect to the aged and degraded material. As the result of experimental work in this study, GTD-111 and GTD-222 Ni-based superalloys were collected and analyzed quantitatively through microscopic observation, microhardness evaluation and creep test.

  • PDF

Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study

  • Kim, Young-Koo;Lee, Hae-Jin;Kim, Jihee
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.159-165
    • /
    • 2020
  • Background and Objectives The ultimate goal in current skin rejuvenation practice is to achieve a good result with minimal pain and downtime. Nonablative skin rejuvenation (NSR) is one technique. The efficacy of the long-pulsed 1064 nm Nd:YAG laser (LPNDY) has not been assessed in NSR. Materials and Methods Three target areas were selected (bilateral cheeks and glabellar region) in six volunteer subjects. A LPNDY with an integral skin temperature monitor delivered three stacked shots to each target area (1064 nm, 12 mm spot, 13 J/cm2, 1 Hz) without any skin cooling or anesthesia. The skin temperature was recorded before, during, and after each set of shots using the system monitor and in real-time using a high-sensitivity (±0.001℃) near-infrared video camera. The skin reaction was observed with the naked eye, and pain and discomfort were assessed by the subjects during and after treatment. Results The subjects reported a mild feeling of heat with no discomfort during or after the test treatments. Mild erythema was observed around the treatment areas, without noticeable edema. A series of three ascending skin temperature stepwise peaks, with a decrease in skin temperature towards the baseline after the third shot, was observed consistently. The mean temperatures for shots 1, 2, and 3 for the cheeks were 39.5℃, 42.0℃, and 44.4℃, respectively, and for the glabella, 40.8℃, 43.9℃, and 46.2℃, respectively. Similar ranges were indicated on the system integral temperature monitor. Conclusion A set of three stacked pulses with the LPNDY at a low fluence achieved ideal dermal temperatures to achieve some dermal remodeling but without any downtime or adverse events. The temperature data from the integral thermal sensor matched the video camera measurements with practical accuracy for skin rejuvenation requirements. These data suggest that LPNDY would satisfy the necessary criteria to achieve effective NSR, but further studies will be needed to assess the actual results in clinical practice.

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.