• 제목/요약/키워드: Reinforcement-reduction

검색결과 476건 처리시간 0.027초

섬유판보강공법에서 휨설계식에 대한 연구 (Flexural Design of Externally Bonded FRP Systems for Strengthening Concrete Structures)

  • 서정국;임종범;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.463-468
    • /
    • 2002
  • For the Externally bonded FRP systems, flexural design method is studied focusing on the reinforcement layer of the carbon fiber sheets. As the FRP layer is added, strengthening rate increases, but not proportionally as the FRP layer increases. This is reflected in the design formula appropriately by the bond cofficients from the added layers. As the number of FRP layer increases, the stress reinforcement and FRP sheet decreases, and it generally corresponds to the decrease rate of member flexural strength. This phenomenon is appearing indentically in a design formula and experimental result. The rate of $M_{test}$ and $M_n$ is 1.19 and it is estimated as safety factor which is the reduction factor, ${\psi}_f = 0.85$.

  • PDF

Seismic Performance and Retrofit of Circular Bridge Piers with Spliced Longitudinal Steel

  • Chung, Young-Soo;Lee, Jae-Hyung
    • KCI Concrete Journal
    • /
    • 제14권3호
    • /
    • pp.130-137
    • /
    • 2002
  • It is known that lap splice in the longitudinal reinforcement of reinforced concrete(RC) bridge columns is not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were practically located in the potential plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. The objective of this research is to evaluate the seismic performance of reinforced concrete(RC) bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, to develop the enhancement scheme of their seismic capacity by retrofitting with glassfiber sheets, and to develop appropriate limited ductility design concept in low or moderate seismicity region. Nine test specimens in the aspect ratio of 4 were made with three confinement ratios and three types of lap splice. Quasi-static test was conducted in a displacement-controlled way under three different axial load levels. A significant reduction of displacement ductility ratios was observed for test columns with lap splices of longitudinal steels.

  • PDF

폐타이어와 토목섬유에 의한 지반보강효과의 비교연구 (A Comparative Study on Soil-reinforcing Effect by Waste Tires and Geocell)

  • 윤여원;김방식;서덕성
    • 한국지반공학회논문집
    • /
    • 제20권5호
    • /
    • pp.59-66
    • /
    • 2004
  • 본 연구에서는 토목섬유의 일종인 지오셀과 새로 고안된 폐타이어로 제작된 타이어셀, 타이어 매트의 지반보강 효과를 비교ㆍ고찰 하였다. 동일한 밀도, 복토두께 조건에서 실험용 토조내 평판재하시험을 수행하였다. 시험결과 타이어셀과 타이어측면의 조합 보강재가 가장 큰 지지력 증가와 침하량 감소를 나타내었다. 타이어셀과 같은 높이로 만든 지오셀의 보강효과는 타이어측면으로 만든 매트와 유사한 보강효과를 나타냈다.

Three-dimensional free vibration analysis of functionally graded fiber reinforced cylindrical panels using differential quadrature method

  • Yas, M.H.;Aragh, B. Sobhani;Heshmati, M.
    • Structural Engineering and Mechanics
    • /
    • 제37권5호
    • /
    • pp.529-542
    • /
    • 2011
  • Three dimensional solutions for free vibrations analysis of functionally graded fiber reinforced cylindrical panel are presented, using differential quadrature method (DQM). The orthotropic panel is simply supported at the edges and is assumed to have an arbitrary variation of reinforcement volume fraction in the radial direction. Suitable displacement functions that identically satisfy the simply supported boundary condition are used to reduce the equilibrium equations to a set of coupled ordinary differential equations with variable coefficients, which can be solved by differential quadrature method to obtain natural frequencies. The main contribution of this work is presenting useful results for continuous grading of fiber reinforcement in the thickness direction of a cylindrical panel and comparison with similar discrete laminate composite ones. Results indicate that significant improvement is found in natural frequency of a functionally graded fiber reinforced composite panel due to the reduction in spatial mismatch of material properties.

철근콘크리트 내진벽의 구조성능 평가 및 개선 (Evaluation and Improvement of Structural Performance of Reinforced Shear Walls Under Load Reversals)

  • 신종학;하기주;안준석;주정준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.683-688
    • /
    • 1999
  • The purpose of this study is to develop and evaluate the structural performance of various shear walls, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crashing due to slippage prevention of boundary region and reduction of diagonal tension rather than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by 1.14 times and 1.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

특수 가공된 셀룰로오스섬유보강 콘크리트의 초기 특성 (Properties of Specialty Cellulose Fiber Reinforced Concrete at Early Ages)

  • 원종필;박찬기
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.349-354
    • /
    • 1999
  • Specialty cellulose fibers processed for the reinforcement of concrete offer relatively high levels of elastic modulus and bond strength. The hydrophilic surfaces of specialty cellulose fibers facilitate their dispersion and bonding in concrete. Specialty cellulose fibers have small effective diameters which are comparable to the cement particle size, and thus promote close packing and development of dense bulk and interface microstructure in the matrix. The relatively high surface area and the close spacing of specialty cellulose fibers when combined with their desirable mechanical characteristic make them quite effective in the suppression and stabilization of microcracks in the concrete matrix. The properties of fresh mixed specialty cellulose fiber reinforced concrete and the contribution of specialty cellulose fiber to the restrained shrinkage crack reduction potential of cement composites at early age and theirs evaluation are presented in this paper. Results indicated that specialty cellulose fiber reinforcement showed an ability to reduce the total area significantly (as compared to plain concrete and polypropylene fiber reinforced concrete.

  • PDF

공동주택 리모델링 현장의 바닥충격음 저감대책 (Reduction Method for Floor Impact Noise on APT Remodeling)

  • 박철용;홍구표;이중원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.524-525
    • /
    • 2009
  • Heavy-weight impact noise(HN) is the most irritating noise in Korean apartment houses. It has been proclaimed standard floor system of 210mm thick slab with isolation material in the wall type structure. But this regulation is applied only new construction field and is not considered remodeling field. In general, the LN can be reduced by using isolation material but HN is known as relating with stiffness, strength & boundary condition of slab. Therefore it is difficulty in improving the HN on remodeling field. In this study, We conducted the reinforcement of concrete slab using C.F.S.(carbon fiber sheet), steel plate and steel beam after on-dol with isolation material on the remodeling field. As the test results, It appeared using C.F.S was no improved but using steel plate & steel beam were a little improved on HN.

  • PDF

폐타이어에 의한 지반보강효과의 비교 연구 (Comparison of Soil-reinforcing Effect by Waste Tires with Geosynthetics)

  • 윤여원;김방식;서덕성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.364-371
    • /
    • 2004
  • This study presented the reinforcing effect of sands by newly devised $Tirecell^{(R)}$ made by waste tires, tire mat by sidewalls of tires and Geocell. Plate loading tests were conducted for different reinforcing materials at the same condition. The combination of Tirecell and sidewall gives the highest increase of bearing capacity and reduction of settlement. The Geocell with the same hight of Tirecell gives similar reinforcement effect to the tire mat made by sidewalls.

  • PDF

Handymax 급 PC 선 Engine Casing "B" deck 의 진동 저감 (Vibration reduction of the Engine Casing "B" deck in the handymax vessel)

  • 서명갑;정태석;석호일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.498-503
    • /
    • 2009
  • This paper presents the vibration problem of the Engine Casing (E/C) "B" deck in the handymax vessel and describes a method to avoid resonance. The first ship of the series did not have any vibration issue on the "B" deck. However, resonance condition occurred when additional machine was installed to the following vessels. To understand the dynamic characteristics of the deck, the normal mode analysis and impact test have been performed. Within the normal operating range of the vessel, the $1^{st}$ natural frequency of the E/C "B" deck is close to the main engine's $6^{th}$ order. Based on these analysis, a reinforcement on the deck was suggested and it proved to be effective. Since actual impact test after the reinforcement also confirmed the resonance avoidance.

  • PDF

이암지역에 근입된 PRD강관말뚝의 지지력 보강 (Reinforcement for Bearing Capacity of PRD Steel Pile at Mudstone Area)

  • 공진영;강희진;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1760-1769
    • /
    • 2007
  • The cut slope sliding which has been frequently encountered in Pohang area has been reported due to the rapid reduction of shear strength in mudstone after being exposed to the air. Mudstone has characteristics that it has high enough strength and stiffness in a dry condition, but the strength and stiffness decrease in a wet condition with groundwater infiltration. The case study in this paper shows that mudstone which had enough strength in a boring stage has lost the strength after installing PRD steel pipe pile inducing an insufficient bearing capacity, which has been ascertained by the static load test. Test construction has been performed to investigate the most favorable method for increasing a pile bearing capacity in mudstone with various methods such as MSG (Micro Silica Grouting) around the tip and side of a pile, the perimeter grouting combined with Micro pile reinforcement, and concrete filling after tip reinforcing grouting. From the test construction, MSG has been turned out to be the most favorable method for increasing a pile bearing capacity in mudstone, which has been confirmed by the static load test.

  • PDF