• Title/Summary/Keyword: Reinforcement type

Search Result 886, Processing Time 0.027 seconds

A Study on the Slope Stability Analysis by Shearing Reinforcement of Vegetation Roots -Focused on the Pinus Koraiensis Roots- (식생뿌리의 전단강도 보강에 의한 사면안전율 해석 -잣나무 뿌리를 중심으로-)

  • 조주형;이종성
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.5
    • /
    • pp.80-93
    • /
    • 2000
  • This study measured the shearing resistance of the roots of the Pinus Koraiensis by the tensile strength gained through their individual tensile test for the Root Reinforcement Model. On the basis of the shearing resistance value calculated through such a process the factor of safety(Fs) was comparatively presented by using the simplified Janbu Method in PCSTABL5M, the slop-analyzing software which had been developed in Purdue University of the U.S.A according to the shape of a slope and the type of soil. The results to have measured a stress and the factor of safety(Fs) by experiment are as follows. 1) The mean root diameter of the Pinus Koraiensis used for this experiment was 2.483mm and the mean tensile stress was calculated as 422.846(kgf/$\textrm{cm}^2$). In the strain ratio of material and the elastic modulus was measured 7.8%, 9,291.92(kgf/$\textrm{cm}^2$). 2) The shearing strength including the resistance of soil and root is expressed as Rt=C+Cr+$\sigma$.tan . ΔCr(kg/$\textrm{cm}^2$) of the shearing resistance calculated by estimating the areal ratio of roots at 10 is 0.253(kgf/$\textrm{cm}^2$). 3) As the result of making an analysis of the natural slope stability by the soil parameter, the factor of safety(Fs) was calculated at 1.795 in CL, and the stability analysis of the root reinforcement slope, Fs was calculated at 1.952. However, since a precise analysis of the controlled factors of the slope analyses are demanded for more accurate dynamic analyses, the future demands a study on this.

  • PDF

Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate (고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정)

  • Park, Jong-Bae;Sim, Young-Jong;Chun, Young-Soo;Park, Seong-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.

Creating damage tolerant intersections in composite structures using tufting and 3D woven connectors

  • Clegg, Harry M.;Dell'Anno, Giuseppe;Partridge, Ivana K.
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.2
    • /
    • pp.145-156
    • /
    • 2019
  • As the industrial desire for a step change in productivity within the manufacture of composite structures increases, so does the interest in Through-Thickness Reinforcement technologies. As manufacturers look to increase the production rate, whilst reducing cost, Through-Thickness Reinforcement technologies represent valid methods to reinforce structural joints, as well as providing a potential alternative to mechanical fastening and bolting. The use of tufting promises to resolve the typically low delamination resistance, which is necessary when it comes to creating intersections within complex composite structures. Emerging methods include the use of 3D woven connectors, and orthogonally intersecting fibre packs, with the components secured by the selective insertion of microfasteners in the form of tufts. Intersections of this type are prevalent in aeronautical applications, as a typical connection to be found in aircraft wing structures, and their intersections with the composite skin and other structural elements. The common practice is to create back-to-back composite "L's", or to utilise a machined metallic connector, mechanically fastened to the remainder of the structure. 3D woven connectors and selective Through-Thickness Reinforcement promise to increase the ultimate load that the structure can bear, whilst reducing manufacturing complexity, increasing the load carrying capability and facilitating the automated production of parts of the composite structure. This paper provides an overview of the currently available methods for creating intersections within composite structures and compares them to alternatives involving the use of 3D woven connectors, and the application of selective Through-Thickness Reinforcement for enhanced damage tolerance. The use of tufts is investigated, and their effect on the load carrying ability of the structure is examined. The results of mechanical tests are presented for each of the methods described, and their failure characteristics examined.

Analysis of Damping Performance of Hysteretic Dampers of Buckling restrained Braced Type According to eccentricity of school buildings with Torsional irregularities (비틀림 비정형을 가지는 학교건물의 편심율에 따른 좌굴방지가새형 이력댐퍼의 제진성능분석)

  • Kim, Yu-Seong;Lee, Joon-Ho;Kim, Gee-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2023
  • In the case of a school building, even though it is a regular structure in terms of plan shape, if the masonry infill wall acts as a lateral load resisting element, it can be determined as a torsionally irregular building. As a result, the strength and ductility of the structure are reduced, which may cause additional earthquake damage to the structure. Therefore, in this study, a structure similar to a school building with torsional irregularity was selected as an example structure and the damping performance of the PC-BRB was analyzed by adjusting the eccentricity according to the amount of masonry infilled wall. As a result of nonlinear dynamic analysis after seismic reinforcement, the torsional irregularity of each floor was reduced compared to before reinforcement, and the beams and column members of the collapse level satisfied the performance level due to the reduction of shear force and the reinforcement of stiffness. The energy dissipation of PC-BRB was similar in the REC-10 ~ REC-20 analytical models with an eccentricity of 20% or less. REC-25 with an eccentricity of 25% was the largest, and it is judged that it is effective to combine and apply PC-BRB when it has an eccentricity of 25% or more to control the torsional behavior.

A Study on Behavior Characteristics of Reinforcement Zone of Block Type Mechanically Stabilized E arth Wall by Field Measurement in Curved Section (현장 계측을 통한 블록형 보강토옹벽 곡선부 보강 영역의 거동 특성 연구)

  • Lee, So-Yeon;Kim, Young-Je;Oh, Dong-Wook;Lee, Yong-Joo;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.2
    • /
    • pp.23-36
    • /
    • 2019
  • In this paper, field measurement of the Block Type Mechanically Stabilized Earth (MSE) wall curved section was performed, and the reinforced area of the curved part is studied through the result. MSE method has been applied to various fields because of easy construction and excellent economic efficiency, so that it can be easily access in our life. However due to lack of compaction and stress concentration phenomenon, cracks and collapse occur in the curve of MSE wall, which is important for safety. The cause of collapse is lack of research on curved section, lack of design criteria, lack of construction due to economical efficiency and shortening of construction period, insufficient compaction space. In this study, therefore, it was examined the existing design and construction standards, analyzed the cause through accident examples of the curved section of the Block Type MSE wall. As a result, the horizontal displacement of the curved section was 90% higher than that of the straight section and 60% higher than that of the concave section. In the case of the convex section in the curved section reinforcement region, the maximum displacement is shown in the H/2 section in the horizontal direction from the center of the MSE wall, and the range of influence from H is shown. In the case of the concave section, the maximum displacement is shown in the center, The minimum displacement was confirmed in H/4 section in the horizontal direction from the center of the MSE wall. As a basic study on the reinforcement area rehabilitation through the actual construction of block type MSE wall, the behaviors of the straight part and the curved part were compared and analyzed. And analyzed the reinforced area in order to reduce the damage of the stress concentration phenomenon and secure the safety.

The Study on Field Performance Test of Multi Branch Type Tie(GOLRY TIE) (다지형 침목 현장 성능평가에 관한 연구)

  • Kim, Hae-Gon;Suh, Dong-Seok;Kim, Nam-Hong;Lee, Syeung-Youl
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.162-166
    • /
    • 2011
  • In railway, Tie supports rail and plays a role that distribute train load to the ballast. Also, Tie and ballast resist against external force and fix the track position. But, weakening resistance of ballast and tie cause vertical displacement of tie and track irregularity. For reinforcement of track stiffness and reduction of track irregularity, KORAIL has developed Multi Branch type tie(GLORY Tie) that reinforced resistance than general PCT and installed in order to test in the field. This study measured and analyzed lateral resistance of ballast, wheel load of rail, bending strain of rail foot, vertical displacement and vibration acceleration of tie in order to evaluate performance of Multi Branch type tie in the field. According to the results of test, Multi Branch tie is excellent than general tie about lateral resistance of ballast and vertical displacement of tie. And, gap of measurement value between Multi Branch type tie and general tie about wheel load of rail, bending strain of rail foot were very small.

  • PDF

A Case Study on Construction and Design of the Wedge Type Removable Soil Nailing System (쐐기형 제거식 쏘일 네일링 시스템의 설계 및 시공사례)

  • Han, Yeon-Jin;Park, Si-Sam;Kwon, Hyuk-Jun;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.240-247
    • /
    • 2010
  • The soil nailing system is becoming common as reinforcement method of slope face in soil. It has application to obtain slope stability method and scaffolding system. It has some troubles when the soil nailing system is applied to the downtown because it could be invaded someone's private area. Thus, in this paper, wedge type removable soil nailing system which can easily remove deformed bar in final excavation step is developed. Field pull-out test is performed to evaluate deformed bars removal and pullout resistance characteristics. According to this result, application of Wedge Type Removable Soil Nailing System is performed.

  • PDF

A Study on the manage of efficiency of electric facilities for a type of Medium-small building (중.소형 건축물설비의 효율적 전력관리방안 연구)

  • Lee, Sang-Chip;Park, In-Duck;Lee, Won-Goo;Kim, Dae-Gwun;Oh, Bong-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.838-840
    • /
    • 1998
  • The power demand has increased the groth of industry and improvement of life. Otherwise the power supply is more difficult. because of regional egoism, reinforcement for environment, and investment of money. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper is made a study for the method of energy saving and for energy saving of medium-small type small type-below 500kW medium type-between $500{\sim}1.000kW$.

  • PDF

Behaviour of Reinforced Earth Wall with Steel Framed-Facing based on Field Test (현장시험을 이용한 강재틀 보강토옹벽의 안정성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.37-47
    • /
    • 2011
  • This paper describes the stability evaluation of reinforced earth wall with steel framed-facing based on field test. The reinforced earth wall with steel framed-facing is composed of wall facing, reinforcement and backfill soil. The wall facing is assembled by steel frames and the aggregates are filled in that. The reinforcement is steel strip type based on bearing resistance. Field test is conducted to evaluate for two separate sections and the measurement is conducted according to construction elapsed time of structure for earth pressure, horizontal displacement of wall facing and reinforcement strain. The evaluation results show that the measured earth pressure is less than theoretical earth pressure due to dispersion effect of earth pressure by the applied reinforcement. Also, the horizontal displacement of wall facing satisfied a empirical criteria and the measured strain of reinforcement had nearly no effect on stability of structure. Therefore, the reinforced earth wall with steel framed-facing has a structural stability and it can be commonly used in field.

Shear Friction Strength Model of Concrete considering Transverse Reinforcement and Axial Stresses (축응력 및 횡보강근을 고려한 콘크리트의 전단마찰내력 평가모델)

  • Hwnag, Yong-Ha;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.167-176
    • /
    • 2016
  • Shear friction strength model of concrete was proposed to explain the direct friction mechanism at the concrete interfaces intersecting two structural elements. The model was derived from a mechanism analysis based on the upper-bound theorem of concrete plasticity considering the effect of transverse reinforcement and applied axial loads on the shear strength at concrete interfaces. Concrete was modelled as a rigid-perfectly plastic material obeying modified Coulomb failure criteria. To allow the influence of concrete type and maximum aggregate size on the effectiveness strength of concrete, the stress-strain models proposed by Yang et al. and Hordijk were employed in compression and tension, respectively. From the conversion of these stress-strain models into rigidly perfect materials, the effectiveness factor for compression, ratio of effective tensile strength to compressive strength and angle of concrete friction were then mathematically generalized. The proposed shear friction strength model was compared with 91 push-off specimens compiled from the available literature. Unlike the existing equations or code equations, the proposed model possessed an application of diversity against various parameters. As a result, the mean and standard deviation of the ratios between experiments and predictions using the present model are 0.95 and 0.15, respectively, indicating a better accuracy and less variation than the other equations, regardless of concrete type, the amount of transverse reinforcement, and the magnitude of applied axial stresses.