• Title/Summary/Keyword: Reinforcement Cracking

Search Result 364, Processing Time 0.025 seconds

Development and Evaluation of Accelerated Reflection Cracking Test System in Shear Mode (전단 반사균열 모사 실험방법 개발 및 적용성 연구)

  • Kim, Kwang-Woo;Yim, Sung-Bin;Doh, Young-Soo;Rhee, Suk-Keun
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.97-106
    • /
    • 1999
  • This study was conducted to develop a test system for evaluating resistance against reflection cracking in shear mode caused by wheel load in asphalt concrete overlaid on the deteriorated cement concrete pavement. Reflection cracking resistance of selected polymer modified asphalt(PMA) mixtures with and without reinforcement was evaluated using this test system. It was shown that the test results accounted for the effectiveness of materials and reinforcement characteristics in terms of the difference in the resistance against reflection cracking. A shear failure life of a certain mixture was estimated with a high coefficient of determination. when the test results were used in a well known prediction model. Therefore, it seemed to be possible to use this technique for predicting a relative service life of on overlay.

  • PDF

Analysis of Tube Support Plate Reinforcement Effects on Burst Pressure of Steam Generator Tubes with Axial Cracks (증기발생기 전열관지지판의 축균열 파열억제 효과 분석)

  • Kang, Yong Seok;Lee, Kuk Hee;Kim, Hong Deok;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.168-173
    • /
    • 2015
  • A steam generator tubing is one of the main pressure boundary of the reactor coolant system in the nuclear power plants. Structural integrity refers to maintaining adequate margins against failure of the tubing. Burst pressure of a tube at tube support plate can be higher than that for a free-span tube because failure behaviors could be interfered from the tube support plate. Alternative repair criteria for out-diameter stress corrosion cracking indications in tubes to the drilled type tube support plate were developed, however, there are very limited information to the eggcrate type tube support plate. This paper discussed reinforcement effect of steam generator tube burst pressure with axial out-diameter stress corrosion cracking within an eggcrate type tube support plate. A series of tube burst tests were performed under the room temperature and it was found out that there is no significant but marginal effects.

Numerical simulation of columns with un-bonded reinforcing bars for crack control

  • Chen, G.;Fukuyama, H.;Teshigawara, M.;Etoh, H.;Kusunoki, K.;Suwada, H.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.4
    • /
    • pp.409-426
    • /
    • 2007
  • Following previous work carried out in Building Research Institute in Japan, finite element analyses of conceptual column designs are performed in this paper. The effectiveness of the numerical model is evaluated by experimental tests and parametric studies are conducted to determine influential factors in conceptual column designs. First, three different column designs are analysed: bonded, un-bonded, and un-bonded with additional reinforcing bars. The load-displacement curves and cracking patterns in concrete are obtained and compared with experimental ones. The comparisons indicate that the finite element model is able to reflect the experimental results closely. Both numerical and experimental results show that, the introduction of un-bonded zones in a column end can reduce cracking strains, accordingly reduce the stiffness and strength as well; the addition of extra reinforcement in the un-bonded zones can offset the losses of the stiffness and strength. To decide the proper length of the un-bonded zones and the sufficient amount of the additional reinforcing bars, parametric studies are carried out on their influences. It has been found that the stiffness of un-bonded designs slightly decreases with increasing the length of the un-bonded zones and increases with the size of the additional reinforcing bars.

Effect of External Reinforcement on Stress/strain Characteristics of Critical Current in Ag Alloy Sheathed Bi-2212 Superconducting Tapes (Bi-2212 초전도 테이프에서 임계전류의 응력/변형률 특성에 미쳐는 외부강화의 영향)

  • ;K. Katagiri
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.6-10
    • /
    • 2001
  • Stress/stram dependencies of the critical current $I_c$ in AgMgNi sheathed multifilamentary Bi(2212) superconducting tapes were evaluated at 77K, 0T. The external reinforcement was accomplished by soldering Ag-Mg tapes to sin91e side or both sides of the sample. With the external reinforcement. the strength of tapes increased but $I_c$, decreased The $I_c$, degradation characteristic according to the external reinforcement was improved markedly in terms of the stress although it appeared less rectal.table on the basis of the strain. Effects of external reinforcement were discussed in a viewpoint of monitoring sensitivity of cracking in superconducting filaments by considering n-value representing the transport behavior of the current. It is closely associated with the location of them relative to the voltage-monitoring region in the tape.

  • PDF

Structural Performance of Reinforcement corrosion RC Beams Strengthened with Epoxy Mortar System (에폭시모르타르로 보강된 부식철근 RC보의 구조적 성능)

  • Han, Bok-Kyu;Hong, Geon-Ho;Shin, Yeong-Soo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.769-774
    • /
    • 2000
  • The purpose of this study was to investigate the structural performance of reinforcement corrosion reinforced concrete beams strengthened with epoxy mortar system. Main test parameters are existence and the magnitude of the reinforcement corrosion and the reinforcing bar and the tensile reinforcement ratio of the specimens. eight beam specimens were tested to investigate the effectiveness of each test variables on maximum load capacity and failure mode. Test results showed that the ultimate moment of th specimens were higher tan the nominal moment and the flexural stiffness was increased about 2.5 times and the cracking moments occurred over 60% of the failure moment in comparison with same sized control beam. However, note that epoxy mortar may conduct member into brittle failure mode.

  • PDF

Computer aided reinforcement design of RC structures

  • An, Xuehui;Maekawa, Koichi
    • Computers and Concrete
    • /
    • v.1 no.1
    • /
    • pp.15-30
    • /
    • 2004
  • In this study, a design process for reinforced concrete structures using the nonlinear FEM analysis is developed. Instead of using the nonlinear analysis to evaluate the required performance after design process, the nonlinear analysis is applied before designing the reinforcement arrangement inside the RC structures. An automatic reinforcement generator for computer aided reinforcement agreement is developed for this purpose. Based on a nonlinear FEM program for analyzing the reinforced concrete structure, a smart fictitious material model of steel, is proposed which can self-adjust the reinforcement to the required amount at the cracking location according to the load increment. Using this tool, the reinforcement ratio required at design load level can be decided automatically. In this paper, an example of RC beam with opening is used to verify the proposed process. Finally, a trial design process for a real size underground RC LNG tank is introduced.

Behaviour of fiber reinforced concrete beams with spliced tension steel reinforcement

  • Safan, Mohamed A.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.5
    • /
    • pp.623-636
    • /
    • 2012
  • The aim of the current work is to describe the flexural behaviour of simply supported concrete beams with tension reinforcement spliced at mid-span. The parameters included in the study were the type of the concrete, the splice length and the configuration of the hooked splice. Fifteen beams were cast using an ordinary concrete mix and two fiber reinforced concrete mixes incorporating steel and polypropylene fibers. Each concrete mix was used to cast five beams with continuous, spliced and hooked spliced tension steel bars. A test beam was reinforced on the tension side with two 12 mm bars and the splice length was 20 and 40 times the bar diameter. The hooked bars were spliced along 20 times the bar diameter and provided with 45-degree and 90-degree hooks. The test results in terms of cracking and ultimate loads, cracking patterns, ductility, and failure modes are reported. The results demonstrated the consequences due to short splices and the improvement in the structural behaviour due to the use of hooks and the confinement provided by the steel and polypropylene fibers.

Influence of viscous phenomena on steel-concrete composite beams with normal or high performance slab

  • Fragiacomo, M.;Amadio, C.;Macorini, L.
    • Steel and Composite Structures
    • /
    • v.2 no.2
    • /
    • pp.85-98
    • /
    • 2002
  • The aim of the paper is to present some results about the influence of rheological phenomena on steel-concrete composite beams. Both the cases of slab with normal and high performance concrete for one and two-span beams are analysed. A new finite element model that allows taking into account creep, shrinkage and cracking in tensile zones for concrete, along with non-linear behaviour of connection, steel beam and reinforcement, has been used. The main parameters that affect the response of the composite beam under the service load are highlighted. The influence of shrinkage on the slip over the supports is analysed, together with the cracking along the beam. At last, by performing a collapse analysis after a long-term analysis, the influence of rheological phenomena on the ductility demand of connection and reinforcement is analysed.

Review of design parameters for FRP-RC members detailed according to ACI 440.1R-06

  • Jnaid, Fares;Aboutaha, Riyad
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.105-121
    • /
    • 2013
  • This paper investigates the parameters that control the design of Fiber Reinforced Polymer (FRP) reinforced concrete flexural members proportioned following the ACI 440.1R-06. It investigates the critical parameters that control the flexural design, such as the deflection limits, crack limits, flexural capacity, concrete compressive strength, beam span and cross section, and bar diameter, at various Mean-Ambient Temperatures (MAT). The results of this research suggest that the deflection and cracking requirements are the two most controlling limits for FRP reinforced concrete flexural members.

An effective stiffness model for RC flexural members

  • Balevicius, Robertas
    • Structural Engineering and Mechanics
    • /
    • v.24 no.5
    • /
    • pp.601-620
    • /
    • 2006
  • The paper presents an effective stiffness model for deformational analysis of reinforced concrete cracked members in bending throughout the short-term loading up to the near failure. The method generally involves the analytical derivation of an effective moment of inertia based on the smeared crack technique. The method, in a simplified way, enables us to take into account the non linear properties of concrete, the effects of cracking and tension stiffening. A statistical analysis has shown that proposed technique is of adequate accuracy of calculated and experimental deflections data provided for beams with small, average and normal reinforcement ratios.