New emerging surface treatment of GFRP Hybrid bar for stronger durability of concrete structures

  • Park, Cheolwoo;Park, Younghwan;Kim, Seungwon;Ju, Minkwan
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.593-610
    • /
    • 2016
  • In this study, an innovative and smart glass fiber-reinforced polymer (GFRP) hybrid bar was developed for stronger durability of concrete structures. As comparing with the conventional GFRP bar, the smart GFRP Hybrid bar can promise to enhance the modulus of elasticity so that it makes the cracking reduced than the case when the conventional GFRP bar is used. Besides, the GFRP Hybrid bar can effectively resist the corrosion of conventional steel bar by the GFRP outer surface on the steel bar. In order to verify the bond performance of the GFRP hybrid bar for structural reinforcement, uniaxial pull-out test was conducted. The variables were the bar diameter and the number of strands and pitch of the fiber ribs. Tensile tests showed a excellent increase in the modulus of elasticity, 152.1 GPa, as compared to that of the pure GFRP bar (50 GPa). The stress-strain curve was bi-linear, so that the ductile performance could be obtained. For the bond test, the entire GFRP hybrid bar test specimens failed in concrete splitting due to higher shear strength resulting in concrete crushing as a function of bar deformation. Investigation revealed that an increase in the number of strands of fiber ribs enhanced the bond strength, and the pitch guaranteed the bond strength of 19.1 mm diameter hybrid bar with 15.9 mm diameter of core section of deformed steel the ACI 440 1R-15 equation is regarded as more suitable for predicting the bond strength of GFRP hybrid bars, whereas the CSA S806-12 prediction is considered too conservative and is largely influenced by the bar diameter. For further study, various geometrical and material properties such as concrete cover, cross-sectional ratio, and surface treatment should be considered.

파괴모드 추정방법을 이용한 모르타르 충전식 슬리브 철근이음의 강성 평가 (Evaluation on Stiffness of Mortar-filled Sleeve Splice Using Estimation Method of Failure Mode)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.27-34
    • /
    • 2012
  • 본 연구에서는 기존의 모르타르 충전식 슬리브 철근이음에 대한 부착강도식으로부터 유도한 이 철근이음의 파괴모드 추정방법을 이용하여, AIJ 규준에 의하여 평가한 이 슬리브 철근이음의 강성을 검토하였다. 이것을 위하여 261개 모르타르 충전식 슬리브 철근이음의 기존 실험자료를 채택하여 실험의 결과를 분석한 결과에 의하면 모르타르 충전식 철근이음의 파괴모드 추정방법은 돌기가 없는 강관 슬리브에 SD500 철근을 사용한 철근이음을 제외한 모르타르 충전식 슬리브 철근이음에 대한 강성을 효과적으로 평가할 수 있었다. 그리고 이 슬리브 철근이음의 파괴모드 추정방법에 적용하여 철근의 인장파단 영역에 있는 실험체 중에 주물 슬리브와 돌기가 있는 강관 슬리브를 사용한 실험체에서 SD400 철근을 사용한 경우는 98%, SD500 철근을 사용한 경우는 모든 실험체가 단조가력 시의 강성이 AIJ 규준의 A급 이상인 것으로 나타났고, 철근의 인장파단 영역에 있는 모든 실험체는 슬리브의 종류와 슬리브에 매입한 철근 종류에 관계없이 반복가력 시의 강성이 AIJ 규준의 A급 이상인 것으로 나타났다.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

닫힘모멘트를 받는 우각부의 보강철근량 산정에 관한 연구 (A Study on Reinforcing Bar Computation of Corner Joint in Closing Moment)

  • 이명곤;정제평;모귀석;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.239-244
    • /
    • 2002
  • The reinforcing bar computation have to be reflected stress distribution and geometrical condition of a comer joint when the closing moment acted at comer joint. This study analyzes stress distribution of a corner joint with statically determinate truss model. Compared with FEM analysis and result of truss model suggested design method consider strengthening efficiency of main reinforcement.

  • PDF

FRP Bar를 휨 및 전단보강근으로 사용한 콘크리트 보의 전단강도 (Shear strength of concrete beam using FRP Bars for flexure and shear reinforcements)

  • 박현영;장희석;김명식;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.399-402
    • /
    • 2005
  • This paper presents shear strength of concrete beam using FRP bars for flexure and shear reinforcements. Generally, the material properties of FRP bar are different from steel reinforcement. So, the shear strength correction factor is proposed through the experimental results.

  • PDF

철근콘크리트 깊은 보에서 수평 전단철근의 전단저항에 관한 실험적 연구 (An Experimental Study on the Shear Resistance of Horizontal Shear Reinforcement in R.C. Deep Beams)

  • 양근혁;이영호;은희창;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.903-906
    • /
    • 2001
  • The objective of this experimental study was to understand the effect of horizontal shear bar on the shear behavior of R.C. deep beams. Therefore, in the test program, the horizontal shear bar ratio($\rho_{sh}$) and shear span-to-overall depth ratio(a/h) are considered as two main variables. Test results indicate that for deep beams with a/h equal to 1.0, horizontal shear bar is less efficient in restricting the diagonal crack width development and enhancing the ultimate shear strength. So, it can be concluded that shear resistance of horizontal shear bar is related to a/h rather than clear span-to-effective depth ratio($l_{n}$/d) recommended in ACI code.

  • PDF

표면피복종류에 따른 복합열화환경하의 철근콘크리트 부식특성에 관한 실험적 연구 (An experimental study on corrosion properties of reinforcing steel under environment of complex deterioration)

  • 조봉석;김영덕;윤종기;김재환;김용로;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.86-89
    • /
    • 2003
  • It is recognized that reinforcement corrosion is the main distress behind the present concern regarding concrete durability. In this study, to confirm corrosion of reinforced concrete affected by thickness of cover, kinds of surface coating, measured electric potential, ratio of corrosion area, weight reduction, corrosion velocity of steel bar under environment of complex deterioration. The results showed that an increase in age also increases corrosion of steel bar. Ratio of corrosion area is largely related to ratio of weight reduction. as well, corrosion of steel bar by thickness of cover is superior to l0mm thick than 20mm thick. It showed that an increase in thickness of cover prevent steel bar from deteriorating. The results of this study showed that corrosion velocity was affected by thickness of cover, kinds of surface coating. data on the development of corrosion velocity made with none, organic B, organic A, inorganic B, and inorganic A is shown.

  • PDF

주철근 겹침이음을 갖는 철근콘크리트 교각의 비탄성 거동 및 연성능력에 관한 해석적 연구 (Analytical Study on Inelastic Behavior and Ductility Capacity of Reinforced Concrete Bridge Columns with Lap Splices)

  • 김태훈;김운학;신현목;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.931-936
    • /
    • 2003
  • Lap splices were located in the plastic hinge region of most bridge piers that were constructed before the adoption of the seismic design provision of Korea Highway Design Specification on 1992. Lap splicing is also permitted if hoops or spiral reinforcement are provided over the lap length in the current seismic design provision. But sudden brittle failure of lap splices may occur under inelastic cyclic loading. The purpose of this study is the analytical prediction of nonlinear hysteretic behavior and ductility capacity of reinforced concrete bridge piers with lap splices under cyclic loading. For this purpose, a nonlinear analysis program, RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology) is used. Lap spliced bar element is developed to predict behaviors of lap spliced bar. Maximum bar stress and slip of lap spliced bar is considered.

  • PDF

철근의 Bending and Straightening에 대한 실험적 연구 (An Experimental Study on the Cold Bending of Reinforcing Bar)

  • 조현우;최희복;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.109-113
    • /
    • 2003
  • In this experiment, we distribute the bending angle to 60$^{\circ}$, 90$^{\circ}$, 120$^{\circ}$, and we separate it in to two groups. One is straightening right after bending and the other is straightening after one week. The bars we will use are HD13 and HD16. The number of tests will be 60 times. In the case of HD16, the increase of bending angle decreased yield strength and maximum strength. And compared with thinner bars, HD16 showed bigger differences in yield strength and maximum strength when the 'being bent' duration got longer. So it shows that when we bend and after straighten a bar, stress change takes place on the surface of the bar. At the beginning it shows it's ductility after that it deforms while transforming it's character to destroying. And also, if we straighten a bar after bending, it doesn't get straighten like the original form. So it makes torsion and this torsion makes moments in different areas.

  • PDF

철근 및 FRP Bar 콘크리트보의 전단변형 특성 (Shear Deformation Characteristics of Concrete Beams Strengthened with Steel/FRP Bar)

  • 신근옥;이창신;김대중;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.277-280
    • /
    • 2006
  • This paper deals with the shear deformation charateristics of concrete beams strengthened with steel/FRP Bar. Applying the shear behavioral model based on shear deformation compatibility to RC beams tested by Ahmed K. El-Sayed et al.(2006), their transverse deformation in the web are calculated at ultimated loads after decoupling the shear carried by arch action in each beams. The calculated transverse deformation at ultimated loads are nearly same for the different reinforcement ratio. From these results, the temporary transverse deformation limit criterion is deduced. Using the proposed temporary limit criterion, the shear strength of concrete beams strengthen with FRP Bar tested by Ahmed K. El-Sayed et al.(2006) is predicted. These predicted values are compared with the measured values and the results are also compared with the current ACI and JSCE equation. The proposed method predicts the ultimate shear capacities more accurately than the equation of ACI and JSCE code. The predictions by the ACI and JSCE code are founded to be very conservative.