• Title/Summary/Keyword: Reinforced by external

검색결과 301건 처리시간 0.024초

Fiber method analysis of rc beam retrofitted with turnbuckle external post-tensioning

  • Lejano, Bernardo A.
    • Computers and Concrete
    • /
    • 제17권1호
    • /
    • pp.67-86
    • /
    • 2016
  • Strengthening as well as correcting unsightly deflections of reinforced concrete (RC) beam may be accomplished by retrofitting. An innovative way to do this retrofitting that is proposed in this study utilizes turnbuckle to apply external post-tensioning. This Turnbuckle External Post-Tensioning (T-EPT) was experimentally proven to improve the serviceability and load carrying capacity of reinforced concrete beams. The T-EPT system comprises a braced steel frame and a turnbuckle mechanism to provide the prestressing force. To further develop the T-EPT, this research aims to develop a numerical scheme to analyze the structural performance of reinforced concrete beams with this kind of retrofitting. The fiber method analysis was used as the numerical scheme. The fiber method is a simplified finite element method that is used in this study to predict the elastic and inelastic behavior of a reinforced concrete beam. With this, parametric study was conducted so that the effective setup of doing the T-EPT retrofitting may be determined. Different T-EPT configurations were investigated and their effectiveness evaluated. Overall, the T-EPT was effective in improving the serviceability condition and load carrying capacity of reinforced concrete beam.

강철도교에 대한 외부 후긴장 보강공법의 적용에 관한 실험 및 해석적 연구 (An Experimental and Analytical study on the Steel Plate Girder Railway bridge in the applying External Post-tensioning Method)

  • 박영훈;조선규;최정열;박용걸
    • 한국철도학회논문집
    • /
    • 제9권2호
    • /
    • pp.151-159
    • /
    • 2006
  • It analyzed the mechanical behaviors of non-ballasted railway bridge (steel plate girder type) with ballast reinforced on the finite element analysis, field test and laboratory test far the static and dynamic responses. The major objective of this study is to investigate the effects and application of reinforcement for steel plate girder railway bridge by the external post-tensioning method. The reinforcement of non-ballast railway bridge had obviously stable dynamic behaviors due to the additional dead force which was ballast. But in case of static behaviors, static displacements and stresses had increased nearly the allowable values. Therefore we analyzed the mechanical behaviors of non-ballasted railway bridge with ballast reinforced and external post-tensioning reinforced on the finite element analysis and laboratory test for the static and dynamic behavior. As a result, the reinforcement of ballasted railway bridge the external post-tensioning method are obviously effective for the additional dead force which is ballast. The analytical and experimental study are carried out to investigate the post-tension force decrease bending behavior and deflection in composite bridge for serviceability. The servicing railway bridge with ballast reinforced has need of the reasonable reinforcement measures which could be reducing the effect of additional dead load that degradation phenomenon of structure by an unusual. stresses and a drop durability.

차량 충돌에 의한 보강토 옹벽의 안정성 평가 (Evaluation of Stability in reinforced Earth Retaining Wall by Vehicle Collision)

  • 안광국;허열;홍기남;안민수
    • 한국지반환경공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.39-46
    • /
    • 2010
  • 기존의 보강토 옹벽의 연구는 보강토 옹벽의 내적 외적파괴에 중점이 되어 연구가 이루어져 왔고 외부 충격에 관한 연구는 지진에 관한 것이 전부인 것이 현실이다. 도로의 발달로 인해서 도로 주변의 보강토 옹벽에 차량의 충돌 같은 외부 충격을 받는 경우가 늘어나고 있다. 그래서 본 연구에서는 신뢰도를 인정받고 있는 범용 유한요소 프로그램인 LS-DYNA를 사용하여 도로 주변 보강토 옹벽을 모델링하였고, NCAC에서 제공하는 8톤 중량의 Ford single unit truck을 이용하여 차량속도에 따른 보강토 옹벽의 거동 양상을 분석하였다. 그리고 향후 도로 주변에 시공되어지는 보강토 옹벽의 충돌에 관한 안정성을 확보하기 위해서 하단에 중력식 옹벽을 적용하였고 또한 높이를(0.5m, 1.0m, 1.5m) 변화시켜가면서 수치해석을 수행하여 보강토 옹벽의 거동을 분석하고 보강토 옹벽의 안정성을 확인 하였다.

Experimental study and numerical investigation of behavior of RC beams strengthened with steel reinforced grout

  • Bencardino, Francesco;Condello, Antonio
    • Computers and Concrete
    • /
    • 제14권6호
    • /
    • pp.711-725
    • /
    • 2014
  • The purpose of this study is to evaluate the behavior and the strength of SRG (Steel Reinforced Grout) externally strengthened Reinforced Concrete (RC) beams by using a nonlinear numerical analysis. The numerical simulation was carried out by using a three-dimensional (3D) finite element model. An interface element with a suitable damage model was used to model the connection between concrete surface and SRG reinforcing layer. The reliability of the finite element 3D-model was checked using experimental data obtained on a set of three RC beams. The parameters taken into consideration were the external configuration, with or without U-end anchorages, the concrete strength, the amount of internal tensile steel reinforcement. Conclusions were made concerning the strength and the ductility of the strengthened beams by varying the parameters and on the effectiveness of the SRG reinforcing system applied with two types of external strengthening configuration.

FRP 긴장재로 외부 보강된 철근콘크리트 보의 피로거동 (Fatigue Behavior of Reinforced Concrete Beams Externally Strengthened using FRP Tendons)

  • 박상렬;홍성룡;김창훈
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.809-817
    • /
    • 2008
  • 최근 사용되고 있은 구조물의 보강 방법 중 내력 및 사용성 향상효과가 타 공법에 비해 월등한 외부 긴장공법이 많이 사용되고 있다. 그러나 외부 긴장재로 보강된 구조물에 대하여 반복하중에 의한 피로 성능에 대한 평가가 부족하고 이에 대한 연구도 매우 부족한 실정이다. 따라서 본 연구에서는 FRP 긴장재로 외부 보강된 철근콘크리트 보의 반복하중에 따른 피로거동 특성을 분석함으로써 외부 긴장공법의 안전성 및 타당성을 평가하고자 하였다. 본 실험연구에서는 비교 변수로 외부 긴장재의 종류(FRP 긴장재, Steel 긴장재)와 하중범위를 채택하여 실험을 실시하였다. 하중은 FRP 보강 시험체의 항복강도를 기준으로 최소하중을 50%로 삼고 최대하중을 70~85%로 변경하여 4점 재하방식으로 sine파를 이용하여 3Hz의 주기로 실험을 실시하였다. FRP 긴장재로 외부 보강된 철근콘크리트 보에 대한 피로 실험연구 결과로부터 FRP 외부 긴장 공법은 FRP 긴장재, deviator에서의 절곡부, 정착장치 등에서 피로에 대한 충분한 안전성이 확인되었다.

탄소섬유 보강판(CFRP)으로 보강된 철근콘크리트보의 강성예측에 관한 연구 (The Study of the Strength Prediction of RC Beam with Externally bonded Carbon Fiber Reinforced Plate)

  • 한상훈;최홍식;홍기남;신동주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.763-768
    • /
    • 2000
  • The purpose of this paper is to predict the flexural strengthening of reinforced concrete beams by the external bonding of carbon fiber reinforced plate(CFRP) to the tension face of the beam. Used computational equation is derived by relation of stress an strain. This equation is applied to four-nondamage beam and tow-preloading beam. Six scale beams were tested to evaluate the strength enhancement provided by the CFRP. And describes the strength enhancement provided to the flexural capacity of reinforced concrete beam by the external bonding of CFRP. An inelastic section analysis procedure was developed that accurately predicts the load displacement response of the retrofitted beams.

  • PDF

Experimental evaluation of external beam-column joints reinforced by deformed and plain bar

  • Adibi, Mahdi;Shafaei, Jalil;Aliakbari, Fatemeh
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.113-127
    • /
    • 2020
  • In this study, the behavior of external beam-column joints reinforced by plain and deformed bars with non-seismic reinforcement details is investigated and compared. The beam-column joints represented in this study include a benchmark specimen by seismic details in accordance with ACI 318M-11 requirements and four other deficient specimens. The main defects of the non-seismic beam-column joints included use of plain bar, absence of transverse steel hoops, and the anchorage condition of longitudinal reinforcements. The experimental results indicate that using of plain bars in non-seismic beam-column joints has significantly affected the failure modes. The main failure mode of the non-seismic beam-column joints reinforced by deformed bars was the accumulation of shear cracks in the joint region, while the failure mode of the non-seismic beam-column joints reinforced by plain bars was deep cracks at the joint face and intersection of beam and column and there was only miner diagonal shear cracking at the joint region. In the other way, use of plain bars for reinforcing concrete can cause the behavior of the substructure to be controlled by slip of the beam longitudinal bars. The experimental results show that the ductility of non-seismic beam-column joints reinforced by plain bars has not decreased compared to the beam-column joints reinforced by deformed bars due to lack of mechanical interlock between plain bars and concrete. Also it can be seen a little increase in ductility of substructure due to existence of hooks at the end of the development length of the bars.

GFRP 보강 폴리머 모르터 3중복합관의 구조적 특성 (Structural Evaluation of Glass-fiber Reinforced 3-Layer Polymer Composite Pipe)

  • 연규석;권윤환;유근우;김남길
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.147-151
    • /
    • 2001
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF

유리섬유 강화플라스틱 복합관의 구조적 특성 (Structural Behavior of Glass-Fiber Reinforced Plastic Composite Pipes)

  • 연규석;김남길;조규우;김동준;최종윤;백종만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.822-827
    • /
    • 2003
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF

Modelling seismically repaired and retrofitted reinforced concrete shear walls

  • Cortes-Puentes, W. Leonardo;Palermo, Dan
    • Computers and Concrete
    • /
    • 제8권5호
    • /
    • pp.541-561
    • /
    • 2011
  • The Finite Element Method (FEM) was employed to demonstrate that accurate simulations of seismically repaired and retrofitted reinforced concrete shear walls can be achieved provided a good analysis program with comprehensive models for material and structural behaviour is used. Furthermore, the analysis tool should have the capability to retain residual damage experienced by the original structure and carry it forward in the repaired and retrofitted structure. The focus herein is to provide quick, simple, but reliable modelling procedures for repair and retrofitting strategies such as concrete replacement, addition of diagonal reinforcing bars, bolting of external steel plates, and bonding of external steel plates and fibre reinforced polymer sheets, thus illustrating versatility in the modelling. Slender, squat, and slender-squat shear walls were investigated. The modelling utilized simple rectangular membrane elements for the concrete, truss bar elements for the steel and FRP retrofitting materials, and bond-link elements for the bonding interface between steel or FRP to concrete. The analyses satisfactorily simulated seismic behaviour, including lateral load capacity, displacement capacity, energy dissipation, hysteretic response, and failure mode.