CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF