• Title/Summary/Keyword: Region-based Image

Search Result 1,862, Processing Time 0.029 seconds

An Interpretation of Symbols in Water Gardens of Old Palaces - Based on the Archetype Theory of Jung - (융(Jung)의 원형론의 관점에서 본 궁궐 수공간의 상징성 - 공간구조와 디테일에 나타난 상징의미를 중심으로 -)

  • Yoon, Mi-Bang;Kim, Han-Bai
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.60-71
    • /
    • 2010
  • The purpose of this paper is to provide a unified examination of apparently quite different gardens in terms of Carl Jung's psychological concepts such as Archetypes, Individualization, and a natural tendency towards balance or wholeness. In Jung's psychological framework, Archetypes are innate, universal prototypes for ideas and function as the first original models upon which all other similar persons, objects or concepts are derived, copied or patterned. Jung proposes that Individualization be achieved through a natural tendency towards balance, especially the balance between the conscious and the unconscious. This paper deals with three gardens, each of which represents a distinct cultural region: Bu-Yong Ji(芙蓉池) at the Changdeok Palace(Oriental), the Patio of the Lions at the Alhambra(Islamic), and the Fountain of Apollo at the Versailles Palace(Western). It is argued that all of three have in common a natural tendency towards balance and symbolize mandala, the archetype of wholeness. Bu-Yong Ji is in the form of quadrangle which embodies Yin and Yang. In the Patio of the Lions, the basin at the center and the four channels, which symbolize the waterway of the Garden of Eden and the four rivers in Paradise respectively, are constructed in the form of a quadripartite composition. The overlapped circle and rectangular shaped pond of the Fountain of Apollo also represents mandala. Symbols representing the same archetype can vary from culture to culture. This explains the differences among the three gardens with respect to specific aspects of external forms. In other words, an archetypal image can give rise to various forms in different cultures, and thus quite different mediums of design or design details may be developed. In conclusion, the three gardens give us a good example as to how an archetypal image can be expressed in different ways from culture to culture and how seemingly different design details can be analyzed in a unified way.

Calculation Method of Oil Slick Area on Sea Surface Using High-resolution Satellite Imagery: M/V Symphony Oil Spill Accident (고해상도 광학위성을 이용한 해상 유출유 면적 산출: 심포니호 기름유출 사고 사례)

  • Kim, Tae-Ho;Shin, Hye-Kyeong;Jang, So Yeong;Ryu, Joung-Mi;Kim, Pyeongjoong;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1773-1784
    • /
    • 2021
  • In order to minimize damage to oil spill accidents in the ocean, it is essential to collect a spilled area as soon as possible. Thus satellite-based remote sensing is a powerful source to detect oil spills in the ocean. With the recent rapid increase in the number of available satellites, it has become possible to generate a status report of marine oil spills soon after the accident. In this study, the oil spill area was calculated using various satellite images for the Symphony oil spill accident that occurred off the coast of Qingdao Port, China, on April 27, 2021. In particular, improving the accuracy of oil spill area determination was applied using high-resolution commercial satellite images with a spatial resolution of 2m. Sentinel-1, Sentinel-2, LANDSAT-8, GEO-KOMPSAT-2B (GOCI-II) and Skysat satellite images were collected from April 27 to May 13, but five images were available considering the weather conditions. The spilled oil had spread northeastward, bound for coastal region of China. This trend was confirmed in the Skysat image and also similar to the movement prediction of oil particles from the accident location. From this result, the look-alike patch observed in the north area from the Sentinel-1A (2021.05.01) image was discriminated as a false alarm. Through the survey period, the spilled oil area tends to increase linearly after the accident. This study showed that high-resolution optical satellites can be used to calculate more accurately the distribution area of spilled oil and contribute to establishing efficient response strategies for oil spill accidents.

Comparative Analysis in Visitors' Perception of Aftermath of the Country's Garden Exposition- Focused on the 2013 Suncheon Bay International Garden Expo, 2015 Seoul Garden Expo, and 2022 Goyang International Flower Fair - (국내정원박람회 개최 효과에 대한 방문객 인식 비교 연구 - 2013 순천만국제정원박람회, 2015 서울정원박람회, 2022 고양국제꽃박람회를 대상으로 -)

  • Kim, Tai-Won;Kim, Gunwoo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.6
    • /
    • pp.58-69
    • /
    • 2022
  • This study compares and analyses the impacts of holding domestic garden expos that will be fundamental for holding garden expos in the future. Satisfaction with the three sites of the 2013 Suncheon Bay International Gardening Expo, 2015 Seoul Gardening Expo, and 2022 Goyang International Flower Fair, as well as factors affecting the satisfaction in economic, social/cultural, environment/ecology, and operation aspects, were analyzed. As a result of the study, the satisfaction level of all three sites was high, with a value of 3.5 or higher. In particular, satisfaction with the 2013 Suncheon Bay International Gardening Expo was the highest. It was found that there was a difference between the satisfaction level of the 2013 Suncheon Bay International Gardening Expo and the 2015 Seoul Gardening Expo. As a regional festival, the 2013 Suncheon Bay International Garden Expo has acquired a high status due to the 'Suncheon Bay Garden' being designated as the first National Garden. It is thought that great satisfaction was obtained because economic, social, cultural, and environmental revitalization was achieved by matching the values of citizen participation and ecological conservation. As a result of the comparison of perception types affecting the satisfaction by garden fair, satisfaction at the 2013 Suncheon Bay International Gardening Expo and the 2015 Seoul Gardening Expo, it was found that both affected all four aspects. The 2022 Goyang International Flower Fair did not affect satisfaction in the operational aspect. This seems to be because the Goyang International Flower Fair is already a fixed local brand. As a result of analyzing the detailed factors of perception that affect satisfaction, the three target sites were commonly analyzed, including social and cultural factors, which attract cultural events, improve pride and affection for the region, and help educate children. In terms of environmental and ecological factors were analyzed as an inconvenience in life due to traffic congestion. It can be seen that it has the same meaning as the comparative analysis of the difference in factors on the satisfaction of the target site. There is no difference in the effect on satisfaction in terms of social·cultural, and environmental·ecological aspects, but there are differences in terms of economy and operation. Based on the analysis results of this study, to hold a domestic garden expo in the future, it is necessary to properly utilize "environmental" and "ecological" garden aspects that have potential values according to the region's characteristics to develop sustainable, eco-friendly tourism resources. In addition, values will be more apparent when cultural and artistic programs are planned to establish a differentiated identity in the host area and are appropriately used as a marketing means for a local fair. A well-planned local festival through communication with local residents can affect the image of the region and lead to the revitalization of the local communities by securing urban competitiveness along with the establishment of urban brands, so it can be said that local residents' participation and national or local organizations' cooperation is essential.

Wavelet Transform-based Face Detection for Real-time Applications (실시간 응용을 위한 웨이블릿 변환 기반의 얼굴 검출)

  • 송해진;고병철;변혜란
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.829-842
    • /
    • 2003
  • In this Paper, we propose the new face detection and tracking method based on template matching for real-time applications such as, teleconference, telecommunication, front stage of surveillance system using face recognition, and video-phone applications. Since the main purpose of paper is to track a face regardless of various environments, we use template-based face tracking method. To generate robust face templates, we apply wavelet transform to the average face image and extract three types of wavelet template from transformed low-resolution average face. However template matching is generally sensitive to the change of illumination conditions, we apply Min-max normalization with histogram equalization according to the variation of intensity. Tracking method is also applied to reduce the computation time and predict precise face candidate region. Finally, facial components are also detected and from the relative distance of two eyes, we estimate the size of facial ellipse.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Application of False Discovery Rate Control in the Assessment of Decrease of FDG Uptake in Early Alzheimer Dementia (조기 알츠하이머 치매의 뇌포도당 대사 감소 평가에서 오류발견률 조절법의 적용)

  • Lee, Dong-Soo;Kang, Hye-Jin;Jang, Myung-Jin;Cho, Sang-Soo;Kang, Won-Jun;Lee, Jae-Sung;Kang, Eun-Joo;Lee, Kang-Uk;Woo, Jong-In;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.374-381
    • /
    • 2003
  • Purpose: Determining an appropriate thresholding is crucial for PDG PET analysis since strong control of Type I error could fail to find pathological differences between eariy Alzheimer' disease (AD) patients and healthy normal controls. We compared the SPM results on FDG PET imaging of early AD using uncorrected p-value, random-field based corrected p-value and false discovery rate (FDR) control. Materials and Methods: Twenty-eight patients ($66{\pm}7$ years old) with early AD and 18 age-matched normal controls ($68{\pm}6$ years old) underwent FDG brain PET. To identify brain regions with hypo-metabolism in group or individual patient compared to normal controls, group images or each patient's image was compared with normal controls usingthe same fixed p-value of 0.001 on uncorrected thresholding, random-field based corrected thresholding and FDR control. Results: The number of hypo-metabolic voxels was smallest in corrected p-value method, largest in uncorrected p-value method and intermediate in FDG thresholding in group analysis. Three types of result pattern were found. The first was that corrected p-value did not yield any voxel positive but FDR gave a few significantly hypometabolic voxels (8/28, 29%). The second was that both corrected p-value and FDR did not yield any positive region but numerous positive voxels were found with the threshold of uncorrected p-values (6/28, 21%). The last was that FDR was detected as many positive voxels as uncorrected p-value method (14/28, 50%). Conclusions FDR control could identify hypo-metaboiic areas in group or individual patients with early AD. We recommend FDR control instead of uncorrected or random-field corrected thresholding method to find the areas showing hypometabolism especially in small group or individual analysis of FDG PET.

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

A Basic Study for the Retrieval of Surface Temperature from Single Channel Middle-infrared Images (단일 밴드 중적외선 영상으로부터 표면온도 추정을 위한 기초연구)

  • Park, Wook;Lee, Yoon-Kyung;Won, Joong-Sun;Lee, Seung-Geun;Kim, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.189-194
    • /
    • 2008
  • Middle-infrared (MIR) spectral region between 3.0 and $5.0\;{\mu}m$ in wavelength is useful for observing high temperature events such as volcanic activities and forest fire. However, atmospheric effects and sun irradiance in day time has not been well studied for this MIR spectral band. The objectives of this basic study is to evaluate atmospheric effects and eventually to estimate surface temperature from a single channel MIR image, although a typical approach utilize split-window method using more than two channels. Several parameters are involved for the correction including various atmospheric data and sun-irradiance at the area of interest. To evaluate the effect of sun irradiance, MODIS MIR images acquired in day and night times were used for comparison. Atmospheric parameters were modeled by MODTRAN, and applied to a radiative transfer model for estimating the sea surface temperature. MODIS Sea Surface Temperature algorithm based upon multi-channel observation was performed in comparison with results from the radiative transfer model from a single channel. Temperature difference of the two methods was $0.89{\pm}0.54^{\circ}C$ and $1.25{\pm}0.41^{\circ}C$ from the day-time and night-time images, respectively. It is also shown that the emissivity effect has by more largely influenced on the estimated temperature than atmospheric effects. Although the test results encourage using a single channel MR observation, it must be noted that the results were obtained from water body not from land surface. Because emissivity greatly varies on land, it is very difficult to retrieval land surface temperature from a single channel MIR data.