• Title/Summary/Keyword: Regeneration temperature

Search Result 328, Processing Time 0.021 seconds

Regeneration and Maturation Induction for the Free-living Gametophytes of Ecklonia cava Kjellman (Laminariales, Phaeophyta) (대형갈조류 감태(Ecklonia cava Kjellman) 유리배우체의 재생 및 성숙 유도)

  • Wi, Mi-Young;Hwang, Eun-Kyoung;Kim, Seong-Cheol;Hwang, Mi-Sook;Baek, Jae-Min;Park, Chan-Sun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.5
    • /
    • pp.381-388
    • /
    • 2008
  • Induction of regeneration and maturation for the free-living gametophytes of Ecklonia cava Kjellman was conducted under various temperature, irradiance and photoperiod conditions. Culture conditions for female or male gametophyte fragments were 4 temperature (5, 10, 15 and $20^{\circ}C$), 4 irradiance (5, 10, 20 and $40{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) and 3 photoperiod (14:10, 12:12 and 10:14 h L:D). Female and male gametophyte fragments were maintained in active regeneration without reaching sexual maturity under $5{\sim}10^{\circ}C$, $5{\sim}10{\mu}mol{\cdot}m-2{\cdot}s-1$, 12:12h or 10:14h (L:D) and $15-20^{\circ}C$, $20-40{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 14:10h (L:D), respectively. Sexual maturation of female and male gametophytes facilitated under $15^{\circ}C$, $20-40{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 14:10h (L:D) and $5-10^{\circ}C$, $5-10{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 10:14h (L:D), respectively. These results provide basic informations to control the regeneration or maturation of the free-living gametophytes for artificial seed production of E. cava.

Spheroplast Formation, Regeneration and Fusion of Flavimonas oryzihabitans KU21 (Flavimonas oryzihabitans KU21의 원형질체 생성, 재생 및 융합)

  • 이수연;임영복;박용근;이영록
    • Korean Journal of Microbiology
    • /
    • v.31 no.4
    • /
    • pp.318-325
    • /
    • 1993
  • The optima] conditions for the formation, the regeneration. and the spheroplast fusion of Flavimonas aryz/habitans spheroplasts were investigated. Cells were transformed to spherop]asts effectively by treatment of 0.5% volume (v/v) of 0.] M EDTA and ]00 flg/ml lysozyme at $37^{\circ}C$ for 30 min without shaking. Magnesium chloride and calcium chloride were effective on the stabilization of spheroplasts. and 20 mM calcium chloride in the rich regeneration medium improve the yield of regenerants as much as 3.5-fo]d. Addition of 0.8% bovine serium albumine (BSA) in dilution buffer for spheroplast formation improved the stabilization of spheroplasts over extended periods (4-6 hr) at room temperature. and thus increased the yield of recombinants to 4.5-fold. The spheroplast formation frequency and regeneration frequency of F aryzihabitans strain was 90.10% and 3.800/." respectively. The first regenerated cell of F. aryzihabitans spheroplasts were appeared 6 hours after plating. By I I hours after plating, 80% of spheroplasts were regenerated on thc rich regeneration medium containing 0.5 M sucrose. The intraspeci11c spheroplast fusion of F urvz/habitans was carried out and the properties of obtained fusants were investigated. Formation of fusion products was effective when the Flav/munas spheroplast mixture was treated with 40%(w/v) PEG6000 and 20 mM CaCl, for 10 min at room temperature. and thc formation of frequency of recombinants were $2.0{\times}10^{-5}~3.6{\times}10^{-5}$. All tested recombinant clones were very stable on further propagation.

  • PDF

The Removal of Carbon Dioxide using AMP+HMDA in Absorption/Regeneration Continuous Process (흡수/재생 연속공정에서 AMP+HMDA를 이용한 이산화탄소의 제거)

  • Choi, Won-Joon;Cho, Ki-Chul;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.507-513
    • /
    • 2005
  • Increasing amounts of anthropogenic $CO_2$ emitted to the atmosphere are believed to be a significant factor in global climate change. Hence, the method of chemical absorption has been suggested to separate and recover acid gases such as $CO_2$. In this study, the characteristics of absorption and regeneration of $CO_2$ for the absorbent which adding HMDA (hexamethylenediamine) into AMP (2-amino-2-methyl-1-propanol), hindered amine, was investigated in lab-scale absorption/regeneration reactor. As a result of this study, the removal efficiency of $CO_2$ increased when adding $5.9\%,\;11.7\%\;and\;23.4\%$ HMDA into $30\%$ AMP respectively. Also, the removal efficiency of $CO_2$ increased $6.5\%,\;8.4\%,\;10.3\%$ respectively as compared to AMP alone when the gas flow rate was 7.5 SL/min. In addition, all absorbents used in the study revealed the high stripping efficiency, which was almost $99\%$, at the temperature of $110^{\circ}C$. Thus, the regeneration tower should be operated at $110^{\circ}C$. At this time, the concentration of exhausted $CO_2$ was higher than $99\%$.

Characteristics of Limestone Regeneration in the wet Limestone FGD Process (습식 석회석 배연 탈황 공정에서의 석회석 재생 특성)

  • 손종렬;문경환;모세영
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This study was performed to develop the modified FGD(Flue Gas Desulfurization) process which can eliminate the possibility of generating secondary pollutants. Limestone was regenerated by adding ammonium hydroxide and carbon dioxide, and reusing it as a absorbent in FGD gypsum Process. A series of the new or modified FGD process which include desulfurization and regeneration limestone from CaSO$_3$. 1/2H20 and CaSO4 . 2H2O, were carried out under various experimental conditions. The results showed that the optimum injection ratio for regeneration of limestone was 0.3 ml/min of CO2 flow rate, 2 ml of NH4OH per 0.01 M of regent grade CaSO4 . 2H20O and the optimum regeneration temperature was 50. The increaser was the number of times of limestone regeneration, the faster was the breakthrough point of desulfurization at the desulfurination process which the regenerated limestone was used. Then the efficiency of desulrurization was decreased. This study can be confirmed the possibility for reuse of regenerated limestone due to the similarity of desulfurization characteries both reagent grade calcium carbonate and regenerated calcium carbonate. Finally, it appeared that the new technology using regenerated 1imestone can be applied to the FGD process.

  • PDF

Development of the Advanced Manganese-Based Sorbent for Hot Coal Gas Desulfurization (고온 석탄 가스 탈황을 위한 개선된 망간계 탈황제 개발)

  • Shon, Byung-Hyun;Choi, Eun-Hwa;Cho, Ki-Chul;Jeon, Dae-Young;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.291-302
    • /
    • 2000
  • This experiments have been made to develop of manganese-based sorbent for the removal of hydrogen sulfide from hot coal gases. Manganese-based sorbent were tested in an ambient-pressure fixed-bed reactor to determine steady state $H_2S$ concentrations, breakthrough times and feasibility of the sorbent when subjected to cycle sulfidation and regeneration testing. Effects of particle size of sorbent, temperature of sulfidation, regeneration temperature and regeneration characteristics on the $H_2S$ removal efficiency were investigated. Experimental results showed that the $H_2S$ removal efficiency was optimal when the temperature was about $800^{\circ}C$ and the smaller particle size, the better $H_2S$ removal efficiency but in the range of 0.214~0.631mm didn't influence it much. The equilibrium constant(K) is represented as a log(K)=3.396/T-1.1105 and the utilization efficiency of sorbents was about 92% at $800^{\circ}C$. Regeneration in air produced $SO_2$ concentration as high as 8.5% at $800^{\circ}C$, 8.4% at $850^{\circ}C$, and 8.8% at $900^{\circ}C$ and may be used in sulfuric acid production.

  • PDF

A Study on Monitoring the Land Surface Temperature Changes Caused by Constructions of Rainwater Villages Using the Multi-temporal Landsat-8 Satellite Images (다중시기 Landsat-8 위성영상을 활용한 빗물마을 조성 사업에 의한 지표면 온도 변화 모니터링에 관한 연구)

  • CHOUNG, Yun-Jae;YU, Ki-Kwang;LEE, Yong Ik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.1
    • /
    • pp.30-40
    • /
    • 2020
  • Monitoring the urban environmental changes caused by the urban regeneration project is necessary for evaluating the effect of the various types of urban regeneration projects that have been carried out in Seoul, South Korea. However, there is few available data and professional expert for evaluating the effect of these urban regeneration projects. This research evaluated the effect of the construction of rainwater village in Jangwi-dong area, constructed through the Seoul urban regeneration project, by utilizing the land surface temperatures derived from the multi-temporal Landsat-8 satellite images through the following steps. In the first step, the land surface temperature images were generated using the multispectral bands of the Landsat-8 satellite images. In the final step, the effect of constructing the rainwater villages was assessed by calculating the seasonal LST statistics for Jangwi-dong area, its neighbor area and entire Seoul area. The experimental results led the following conclusion: the construction of rainwater villages did not have the significant effect on the land surface temperature changes in Jangwi-dong area.

Residual Stress on Concentric Laminated Fibrous Al2O3-ZrO2 Composites on Prolonged High Temperature Exposure

  • Sarkar, Swapan Kumar;Lee, Byong Taek
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.531-536
    • /
    • 2013
  • This paper investigates the effect of prolonged high temperature exposure on concentric laminated $Al_2O_3-ZrO_2$ composites. An ultrafine scale microstructure with a cellular 7 layer concentric lamination with unidirectional alignment was fabricated by a multi-pass extrusion method. Each laminate in the microstructure was $2-3{\mu}m$ thick. An alternate lamina was composed of 75%$Al_2O_3$-(25%m-$ZrO_2$) and t-$ZrO_2$ ceramics. The composite was sintered at $1500^{\circ}C$ and subjected to $1450^{\circ}C$ temperature for 24 hours to 72 hours. We investigated the effect of long time high temperature exposure on the generation of residual stress and grain growth and their effect on the overall stability of the composites. The residual stress development and its subsequent effect on the microstructure with the edge cracking behavior mechanism were investigated. The residual stress in the concentric laminated microstructure causes extensive micro cracks in the t-$ZrO_2$ layer, despite the very thin laminate thickness. The material properties like Vickers hardness and fracture toughness were measured and evaluated along with the microstructure of the composites with prolonged high temperature exposure.

Effect of NO on Catalytic Soot Oxidation in Tight Contact with $Pt/CeO_2$ Using a Flow Reactor System ($Pt/CeO_2$ 촉매와 Tight Contact 한 상태의 Model Soot 산화에 NO가 미치는 영향에 관한 실험적 연구)

  • Lee, Dong-Il;Song, Chang-Hoon;Song, Soon-Ho;Chun, Kwang-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.52-56
    • /
    • 2011
  • Active regeneration in CDPF requires $O_2$ which regenerates soot at high temperature. However, small amount of NO can interrupt $O_2$ regeneration in CDPF. To verify this phenomena, soot oxidation experiments using a flow reactor with a $Pr/CeO_2$ catalyst are carried out to simulate Catalyzed Diesel Particulate Filter (CDPF) phenomena. Catalytic soot oxidation with and without small amount of NO is conducted under tight contact condition. As the heating rate rises, the temperature gap of maximum reaction rate is increased between with and without 50ppm NO. To accelerate the $NO_2$ de-coupling effect, CTO process is performed to eliminate interfacial contact for that time. As CTO process is extended, temperature which indicates peak reaction rate increases. From this result, it is found that small amount of NO can affect tight contact soot oxidation by removal of interfacial contact between soot and catalyst.

Study on the Effect of Performance Factors on the Finned Tube Type Regenerator for Liquid Desiccant Dehumidification (액체 건조제 제습을 위한 핀튜브형 재생기의 성능인자 영향 연구)

  • Jang, Jun-Oh;Park, Moon-Soo;Kang, Kyung-Tae;Lee, Shin-Pyo;Lee, Jin-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.845-852
    • /
    • 2003
  • Liquid desiccant dehumidification system can be used effectively to save energy consumed in air conditioning as an alternative compared with conventional air conditioning systems by reducing latent heat load. The dehumidifier and the regenerator from the heart of this system. The latent part of the cooling load is handled using liquid desiccant. In this study, the experimental regenerator has been designed to study the regeneration characteristics of the aqueous triethylene glycol(TEG) system. The performance factors of the regenerator with finned tube heat exchanger were evaluated by a series of experimental runs. The regeneration process is highly dependent on the liquid desiccant conditions, such as, temperature, concentration and flow rate. In addition, the effects of the inlet air temperature, humidity and flow rate were discussed. Data obtained are useful for design guidance and performance analysis of a regenerator, particularly for a liquid desiccant cooling system.

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.