• 제목/요약/키워드: Refrigerators

검색결과 232건 처리시간 0.028초

Roebuck 냉동기를 응용한 회전형 헬륨 재응축 장치 (Rotating helium-recondensing system using Roebuck refrigerator)

  • 정상권;이창규
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.464-471
    • /
    • 1999
  • This paper describes a design of the helium-recondensing system utilizing cascade Roebuck refrigerators. Superconducting generator or motor has the superconducting field winding in its rotor that should be continuously cooled by cryogen. Since liquid helium transfer from the stationary system to the rotor is problematic, cumbersome, and inefficient, the novel concept of a rotating helium-recondensing system is contrived. The vaporized cold helium inside the rotor is isothermally compressed by centrifugal force and expanded sequentially in cascade refrigerators until the helium is recondensed at 4.2K. There is no helium coupling between the rotor and the stationary liquid helium storage. Thermodynamic analysis of the cascade refrigeration system is performed to determine the key design parameters. The loss mechanisms are also explained to identify entropy generation that degrades the performance of the system.

  • PDF

4 K, 3 Watt급 GM-JT냉동기의 최적설계 (Optimal Design of a 3 Watt GM-JT Refrigeratior at 4 K)

  • 장호명
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.11-19
    • /
    • 1994
  • An optimal design for Gifford-McMahon/Joule-Thomson(GM-JT) refrigerators was performed by a numerical method. The design goal was to meet the cooling requirement for MRI systems, which was 3 Watt at 4 K. A general cycle analysis program was written to calculate the cooling capacity of the GM-JT refrigerators for the givenstage GM refrigerator. The program was executed for a specific refrigerator with various design parameters. The optimal values for the maximum cooling were found for the sizes of the heat exchangers, the mass flow rate of helium, and the compression pressure.

  • PDF

냉장고 기계실 내부 열 유동 특성 해석(II) (Charactericstics of Heat Flow in a Machine Room of Refrigerator(II))

  • 한병윤;김재열;김태훈;김영국;이연원
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.173-179
    • /
    • 2002
  • There is a growing concert about energy efficiency at the present time. Even refrigerators can not be omitted from this issue. So the factors have been searched to decrease the consumption of electric power in refrigerators. It is possible to analyze the numerical data of the cover back machine and the change of condenser shape to find that they affect the consumption of electric powers by improving the fluid flow of within the interior of the refrigerator. As a result, the problems, fluid of the eddy and stationary of the existing refrigerator can be solved partly by the improved model.

  • PDF

오리피스 맥동관 냉동기의 수치적 해석 (Numerical Analysis of an Orifice Pulse Tube Refrigerator)

  • 이강선;정은수;최헌오
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.282-290
    • /
    • 1994
  • A numerical model for the analysis and design of orifice pulse tube refrigerators has been developed. Heat transfer coefficient and friction factors in the model vary with time, and the real physical properties such as thermal conductivity and viscosity were used to improve the accuracy of the model. Thermodynamic behavior of the working fluid within pulse tube refrigerators was investigated and the effect of design parameters, such as reservoir volume, orifice diameter, and NTU of regenerator, on the cooling load and COP was shown.

  • PDF

다구찌 기법을 이용한 3 문형 냉장고 서랍용 롤러 레일의 설계 (Design of a Roller Rail for the Drawer of Three-Door Refrigerators Using Taguchi Method)

  • 이부윤;김제현
    • 한국정밀공학회지
    • /
    • 제26권6호
    • /
    • pp.97-105
    • /
    • 2009
  • Optimal design of a roller rail which replaces the ball rail for three-door refrigerators is presented using the finite element analysis and the Taguchi method. Stress and deformation of the roller rail for an initial design are analyzed and evaluated. Optimal design parameters are determined using the Taguchi method. The maximum stress of the optimal design is favorably reduced comparing to the initial design. It is verified through an additional analysis that the drawer on the roller rail will not be derailed even if one opens the drawer with a transverse force.

B/F형 냉장고 냉동실의 결빙원인에 관한 연구 (Fluid flow in the freezing compartment of the B/F Refrigerators)

  • 양수영;김윤규;박재성;정호윤;이연원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.530-533
    • /
    • 2008
  • Refrigerators have some frost related problems in a freezing compartment. The frost formation in the refrigerator gives customers a bad impression concerning quality problems. Therefore, many engineers have been studying the optimum solution to avoid frost formation. But the problem of frost formation is very complex and hard to approach to the answer. The frost generation of a household refrigerator have been widely known that is closely related to the distribution of temperature inside the compartment. The distribution depends on the cold air circulation inside the refrigerator. So frost problem can be reduced and energy consumption efficiency also improved through optimization of air flow fields inside the freezing compartment. In this paper, numerical simulation has been carried out to check fluid flow. The variation of temperature at the walls was measured and quantitative analysis of frost generated from the freezing compartment was carried out. Through comparison between simulation and experiment, some correlation revealed.

  • PDF

냉장고용 왕복동 압축기 급유 시스템의 수치해석 (Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators)

  • 김현진;이진갑
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

가전기기 에너지소비효율 기준설정에 관한 연구 (Study on Appliance Energy Efficiency Standards)

  • 이선근;최수현
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.144-150
    • /
    • 1996
  • The Energy Efficiency Standards and Labelling Act, as amended by the Rational Energy Utilization Act, provides energy efficiency standards and labellings for six equipment categories(viz, refrigerators, air-conditioners, fluorescent lamps and ballasts, incandescent lamps, cars) authorizes the Ministry of Trade. Industry and Energy (MOTIE) to prescribe amended or new energy efficiency standards and labelling standards. This study was initiated by the KIER(Korea Institute of Energy Research) in 1992. KIER's assessment of the appliance energy efficiency standards is designed to evaluate their statistical and engineering analysis according to Korean Industrial Standards(KS). And to make didtinction between the poor efficiency and good efficiency models. 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, Incandescent lamps, and fluorescent lamps.

  • PDF

냉장고용 롤-플레이트형 휜-관 열교환기의 성능에 관한 연구 (A Study of Performance of Roll-plate type fin-tube Heat Exchanger for the Refrigerator)

  • 안성준;김종수;권오붕;박영종;하영주;최상조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2292-2297
    • /
    • 2008
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new type condenser which will cost less and will be as efficient as the spiral type. The new type condenser consists of a steel tube, steel plates and louver fins attached to the tube. The tube and the plate are bent into a single-passage serpentine shape.

  • PDF