• Title/Summary/Keyword: Refrigerators

Search Result 232, Processing Time 0.022 seconds

Optimal Design for Cushioning Package of a Heavy Electronic Product Using Mechanical Drop Analysis (낙하충격해석을 통한 대형 전자제품의 완충포장재 최적설계)

  • 금대현;김원진;김성대;박상후
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.128-135
    • /
    • 2004
  • Generally, heavy electronic products undergo many different types of shocks in transportation from a manufacturer to customers. Cushioning package is used to protect electronic products from severe shock environments. Since the mass distribution of heavy electronic products is usually unbalanced and complex. it is very difficult to design a cushioning package with having high performance by considering only the equivalent stiffness of that. Therefore, when designing the cushioning package for a heavy electronic product, it is necessary to optimize its shape in order to maximize the cushioning performance. In this study, it is focused on designing an optimal shape of cushioning package for a large refrigerator and an efficient design method is suggested by using a dynamic finite element analysis. As the results of this study the optimal shape of cushioning package, which has high cushioning performance and minimized volume, was obtained through the mechanical drop analysis and a optimization process. Through free drop tests of refrigerators, it was identified that the cushioning performance of the cushioning package was improved up by 25% and the its own volume was reduced by 22 %.

Vibration Reduction Using Wire Mounting - Test Results (Wire Mounting을 이용한 진동저감에 대한 실험 연구)

  • 최상현;박윤식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.403-408
    • /
    • 2001
  • Structure-borne noise and vibration is one of the main complaints of home appliances such as refrigerators, washing machines, air conditioners, etc. There have been many efforts to reduce the emitting noise and vibration. Mostly the efforts have been concentrated to optimize the mounts shape and its material properties realizing that the vibration power is mainly transmitted to the structure via mounts. It is known that softer mounts have the better vibration isolation effect. But mounts have another important function in addition to the vibration isolation. That is to support the motor and compressor safely. Thus mounts should be stiff enough to resist the supporting items. But the two properties, stiff and soft, are contradict each other. So the designer should compromise the two complicity properties properly in between. Noticing that, motors and compressors themselves are very quite until they are connected to the base structure via mounts, wire connecting idea was proposed in this work. Instead of using conventional mounts, as shown in Fig 4, compressor was mounted using six wires as shown in Fig 5. Since wire is very flexible in bending but stiff in tension, we can realize the ideal mount design requirements, stiff enough to support and soft enough to isolate vibration power. The suggesting idea was tested with an air conditioner outdoor unit.

  • PDF

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

Performance Characteristics of Refrigeration and Air Conditioning System Using Hydrocarbon Refrigerants (탄화수소계 냉동공조 시스템의 성능특성에 관한 실험)

  • 이호생;이근태;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.728-734
    • /
    • 2004
  • Environmentally friendly refrigerants with zero ozone layer depletion potential are required to be used in refrigerators and air conditioners due to the difficulties related to ozone layer depletion and global warming. A rigorous study for the system performance with new refrigerants having zero ozone layer depletion potential is inevitable before adopting that as a new fluid. The HFC(Hydrofluorocarbon) potential has been recommended as alternatives. In this paper. system performance in the heat pump facilities were studied using R-290, R-600a. R-1270 as an environment friendly refrigerant. R-22 as a HCFC's refrigerant. The experimental apparatus has been set-up as a conventional vapor compression type heat Pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70mm with 1.315mm wall thickness is used for this investigation. The test results showed that the COP of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of COP was found in R-1270. The refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. The compressor work was obtained with the maximum value in R-1270 and the minimum one in R-22.

Electromagnetic Noise Reduction of Reciprocating Compressor using Random PWM (랜덤 PWM을 이용한 왕복동식 압축기의 전자기소음 저감)

  • 조관열;양순배;김학원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 2000
  • Recently, it is increased to apply the inverter system to household electrical appliances, especially in the air c conditioners, refrigerators and washing machines, to reduce the power consumption and the acoustic noise by t the low speed operation, and to make their functions more comfortable for human beings. For the inverter s systems, however, it is highly required to reduce the undesirable electromagnetic noise and psychoacoustic n noise generated by PWM for variable speed operation. In this paper, the electromagnetic noise for the d detenninistic PWM and random PWM for the reciprocating compressors driven by the brusWess dc motor was a analyzed. It was also verified through the experiment that the elt'Ct$\tau$omagnetic noise was reduced and the s sound quality was improved by applying the random PWM.

  • PDF

Heuristic Algorithm for Performance Improvement of Non-Communication Inverter Type Refrigerator (휴리스틱 기법을 이용한 비통신 인버터형 냉장시스템의 성능개선 알고리즘 개발)

  • Min, Seon Gyu;Kim, Hyung Jun;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.2
    • /
    • pp.133-138
    • /
    • 2017
  • Inverter-Type refrigerators are known to consume less energy by varying the inverter frequency according to indoor temperatures and refrigerant pressure through indoor-outdoor communication. However, many commercial operators cannot afford to replace indoor units with ones capable of communication. In a non-communication configuration, indoor units are connected with an inverter-type outdoor unit without intercommunication abilities. The research goal is finding appropriate operating parameters to achieve energy efficiency. Thus, an operation algorithm with two modes is proposed, i.e., one to search the best operating parameters and one for normal operation with the best parameters. The experimental evaluation showed 11.27% reduction in energy consumption, indicating a good applicability of the algorithm.

Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator (무부하 압축기에 의한 냉장고 기계실 소음의 능동제어)

  • Koo, Jung Mo;Jeong, Weui Bong;Kim, Tae Hoon;Hong, Chinsuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.

Study on Improving Flow Balance and Clamp Force of Family Mold for Refrigerator Shelf (냉장고용 선반 패밀리금형의 유동 밸런스와 클램프힘 개선에 관한 연구)

  • Park, Je-Hong;Yoon, Kyeong-Won;Ko, Chang-Oh;Seo, Sang-Won;Kim, Su-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.561-568
    • /
    • 2014
  • Injection molding industries realize the necessity of developing family molds to improve competitiveness. One of the primary causes of manufacturing defective products is the imbalance of flow in a family mold. In this study, the family mold of a shelf for refrigerators is analyzed by using CAE software. First, the flow balance, clamping force, and injection pressure are analyzed for different gate diameters of two cavities. Second, the flow balance, clamping force, and injection pressure are improved when the two gate valves are open at different times. Finally, the results of filling analysis are compared with the test injection product.

AC loss of HTS magnet for AMR refrigerator using magnetic field formulation and edge element in cylindrical coordinates

  • Kim, Seokho;Park, Minwon;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • AMR (Active Magnetic Regenerative) refrigerators require the large variation of the magnetic field and a HTS magnet can be used. The amount of AC loss is very important considering the overall efficiency of the AMR refrigerator. However, it is very hard to estimate the precise loss of the HTS magnet because the magnetic field distribution around the conductor itself depends on the coil configuration and the neighboring HTS wires interact each other through the distorted magnetic field by the screening current Therefore, the AC loss of HTS magnet should be calculated using the whole configuration of the HTS magnet with superconducting characteristic. This paper describes the AC loss of the HTS magnet by an appropriate FEM approach, which uses the non-linear characteristic of HTS conductor. The analysis model is based on the 2-D FEM model, called as 'magnetic field formulation and edge-element model', for whole coil configuration in cylindrical coordinates. The effects of transport current and stacked conductors on the AC loss are investigated considering the field-dependent critical current. The PDE model of 'Comsol multiphysics' is used for the FEM analysis with properly implemented equations for axisymmetric model.

Influence of Refrigeration Oil on Evaporation Heat Transfer of R-134a in a Horizontal Micro-Fin Tube (냉동유가 수평 마이크로 핀관내 R-134a의 증발열전달에 미치는 영향)

  • 배상철;강태욱;김정훈;정찬영;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.140-150
    • /
    • 1996
  • CFC-12, which has been used most widely in automobile air conditioners and household refrigerators is scheduled to be phased out soon because of its high ozone depletion potential. Now HFC-134a is suggested as an alternative refrigerant for CFC-12. In this Study, we intended to investigate how PAG oil influence evaporation heat transfer and flow pattern, using R-134a and PAG oil influences evaporation heat transfer and flow pattern, using R-134a and PAG oil in the horizontal miro-fin evaporation tube. Experiments were conducted under the flowing est conditions : mass velocity 86-250kg/$m^2$s, heat flux 5-30 ㎾/$m^2$, oil concentration 0-21 wt.% and saturation temperature 5$^{\circ}C$. Local evaporation heat transfer coefficients were found to be higher at the top, side and bottom of the tube in this order. Average heat transfer coefficients turned out to increase with oil concentration increment up to 3 wt.% oil concentration, whereas heat transfer coefficients gradually decreased over 3 wt.% oil concentration, because of oil-rich liquid film was formed on the heat transfer surface. Flow patterns were rapidly transitioned to annular regimes up to 3 wt.% oil concentration. In case of pure refrigerant, measured heat transfer coefficients in the experiments were similar to those of Kandlikar's correlation.

  • PDF