• Title/Summary/Keyword: Refrigerator cycle

Search Result 102, Processing Time 0.032 seconds

Structural and Optical Properties of Self-assembled InAs Quantum Dots as a Function of Rapid Thermal Annealing Temperature (급속 열처리 온도에 따른 자발 형성된 InAs 양자점의 구조 및 광학 특성)

  • Cho, Shin-Ho
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.183-187
    • /
    • 2006
  • We present the effects of rapid thermal annealing (RTA) temperature on the structural and optical properties of self-assembled InAs quantum dot (QD) structures grown on GaAs substrates by molecular beam epitaxy (MBE). The photoluminescence (PL) measurements are performed in a closed-cycle refrigerator as a function of temperature for the unannealed and annealed samples. RTA at higher temperature results in the increase in island size, the corresponding decrease in the density of islands, and the redshift in the PL emission from the islands. The temperature dependence of the PL peak energy for the InAs QDs is well expressed by the Varshni equation. The thermal quenching activation energies for the samples unannealed and annealed at $600^{\circ}C$ are found to be $25{\pm}5meV$ and $47{\pm}5$ meV, respectively.

A Study on the Seasonal Adjustment of Time Series for Seasonal New Product Sales (계절상품 판매매출액 시계열의 계절 조정에 관한 연구)

  • 서명율;이종태
    • Korean Management Science Review
    • /
    • v.20 no.1
    • /
    • pp.103-124
    • /
    • 2003
  • The seasonal adjustment is an essential process in analyzing the time series of economy and business. There are various methods to adjust seasonal effect such as moving average, extrapolation, smoothing and X11. One of the powerful adjustment methods is X11-ARIMA Model which is popularly used in Korea. This method was delivered from Canada. However, this model has been developed to be appropriate for Canadian and American environment. Therefore, we need to review whether the Xl1-ARIMA Model could be used properly in Korea. In this study, we have applied the method to the annual sales of refrigerator sales in A electronic company. We appreciated the adjustment by result analyzing the time series components such as seasonal component, trend-cycle component, and irregular component, with the proposed method.

Innovation Strategy using the TRIZ Creativity in Industry (TRIZ 기법을 이용한 기업 혁신전략)

  • Hwang, In-Keuk;Ahn, Young-Soo;Chung, Lak-Chea
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1453-1459
    • /
    • 2008
  • Successful Six Sigma methodology involves continual success of projects, each incrementally moving the organization closer to its strategic goals of shareholder return and customer satisfaction. However, Six Sigma methodology has some disadvantages in long-term technical strategy parts, systematic technology management techniques and concrete idea creativity methodology. To complement these Six Sigma problems, Triz technique is considered. Triz focuses on solving such problems efficiently, effectively, and creatively. The purpose of this paper is to improve the temperature inspection method of a refrigerator through the DAGEV(Define-Analyze- Generate-Evaluate-Verify) cycle of Triz.

THE DEVELOPMENT OF A LOW NOISE 230 GHZ SIS RECEIVER IN NAGOYA UNIVERSITY

  • XIAO K. C.;OGAWA H.;FUKUI Y.;SUZUKI H.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.413-414
    • /
    • 1996
  • A 230 GHz SIS tunnel junction receiver has been being developed for radio astronomy in Nagoya University. In this heterodyne receiver, we use a $\~$1/3 reduced hight rectangular waveguide SIS mixer with two tuning elements as front end. The mixer block with SIS junction was cooled to 4K with a closed cycle He-gas refrigerator. So far, a double sideband receiver noise temperature lower than l00K in 222-237 GHz is obtained. The receiver exhibits a best DSB noise temperature of 69K at 236 GHz as well as 228 GHz.

  • PDF

Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator (증발기 어큐뮤레이터에서의 버블 소음 규명 및 개선)

  • 박정희;장의영;박윤서
    • Journal of KSNVE
    • /
    • v.6 no.4
    • /
    • pp.513-519
    • /
    • 1996
  • This paper is concerned with the bubble sound at the accumulator which is generated by the difference of the high pressure side and the low pressure side in the cycle of the refrigerator. The causes of the bubble sound generation are verified by the visualized test of the operating refrigerant flow at the accumulator and the measurements of the temperature and pressure. Two cases were tested, one with the accumulator has a orifice and the other with the accumulator hasn't a orifice. So that, it is presented the comparison of the bubble sound levels and spectrums in each cases. To predict the bubble sizes when they are generated, the linearized equation driven by Strasberg is used.

  • PDF

A study for a Performance analysis of Hybrid heat pump Air conditioning system (복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구)

  • Lim, Hyun-Mook;Park, Hee-Moon;Cho, Soo;Sung, Uk-Joo;Park, Jin-Hoon;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

The Monitoring of Abnormal Rotary Compressor using Acoustic Emission (AE를 이용한 회전형 압축기의 이상상태 감시)

  • 정지홍;이기용;강명창;김정석;이감규;안봉열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.328-332
    • /
    • 1996
  • The compressor is one of important elements in refrigerator cycle and play an important role of refrigeration efficiency and quality. Therefore it is very important to monitor state of normal and abnormal compressor. In this research, technic of AE is used for monitoring abnormal rotary compressor and an AE parameter which is a most proper parameter to monitor the abnormal state of compressor is determined by signal processing, Finally, the monitoring result of rotary compressor is agreement with the result of life test.

  • PDF

Simulation of a Polymer-Water Adsorption Refrigerator using Plate-Type Adsorption Heat Exchangers (판형 흡착열교환기를 사용한 폴리머-물 흡착식 냉동기의 성능예측)

  • Kim, Dong-Seon;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • A hydroscopic polymer is used as the adsorbent in an adsorption refrigeration system. A pair of plate-type heat exchangers, thinly coated with the polymer, is simulated using a two-dimensional transient model to predict performance of the system. It is predicted that the system would yield 0.57 kW SCP and 0.47 COP at $80^{\circ}C$ heating and $30^{\circ}C$ cooling temperatures. In comparison with a conventional silica gel-water system, the COP is comparable but SCP is about three times larger. The slow mass diffusion rate of the polymer should be improved for better performance.

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF

A Study on Pump Down Operation Performance of Refrigerator (냉동기 펌프다운 운전성능에 관한 연구)

  • Kim, Chul-Soo;Chung, Han-Shik;Jeong, Hyo-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.