소형 GM 냉동기를 이용한 수소 액화에 관한 시뮬레이션 연구 (A Simulation Study on the Hydrogen Liquefaction through Compact GM Refrigerator)

  • 정하늘;한단비;양원균;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.534-540
    • /
    • 2022
  • Liquid hydrogen has the best storage capacity per unit mass and is economical among storage methods for using hydrogen as fuel. As the demand for hydrogen increases, the need to develop a storage and supply system of liquid hydrogen is emphasizing. In order to liquefy hydrogen, it is necessary to pre-cool it to a maximum inversion temperature of -253℃. The Gifford-McMahon (GM) refrigerator is the most reliable and commercialized refrigerator among small-capacity cryogenic refrigerators, which can extract high-efficiency hydrogen through liquefied hydrogen production and boil of gas re-liquefaction. Therefore, in this study, the optimal conditions for liquefying gas hydrogen were sought using the GM cryocooler. The process was simulated by PRO/II under various cooling capacities of the GM refrigerator. In addition, the flow rate of hydrogen was calculated by comparing with specific refrigerator capacity depending on the pressure and flow rate of a refrigerant medium, helium. Simulations were performed to investigate the optimal values of the liquefaction flow rate and compression pressure, which aim for the peak refrigeration effect. Based on this, a liquefaction system can be selected in consideration of the cycle configuration and the performance of the refrigerator.

4 K, 3 Watt급 GM-JT냉동기의 최적설계 (Optimal Design of a 3 Watt GM-JT Refrigeratior at 4 K)

  • 장호명
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.11-19
    • /
    • 1994
  • An optimal design for Gifford-McMahon/Joule-Thomson(GM-JT) refrigerators was performed by a numerical method. The design goal was to meet the cooling requirement for MRI systems, which was 3 Watt at 4 K. A general cycle analysis program was written to calculate the cooling capacity of the GM-JT refrigerators for the givenstage GM refrigerator. The program was executed for a specific refrigerator with various design parameters. The optimal values for the maximum cooling were found for the sizes of the heat exchangers, the mass flow rate of helium, and the compression pressure.

  • PDF

실제기체의 물성을 이용한 Stirling 냉동기 단열해석 (Adiabatic Analysis of Stirling Refrigerator with Real Gas Properties)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.150-160
    • /
    • 1995
  • A Finkelstein adiabatic analysis is performed for Stirling refrigerator with real gas properties of helium. The mass balance and the energy balance equations are formulated into the form that is convenient for incorporating an available computer code of the helium properties. The differential equations are solved numerically. The calculated coefficient of performance(COP) and the pressure variation are compared with the results obtained when helium is assumed to be an ideal gas. The relative errors in COP are presented as functions of the refrigeration temperature and the maximum cycle pressure.

  • PDF

냉동기 팽창장치로서 인젝터 사용의 적합성에 관한 연구 (Study on the Adaptiveness of Using an Injector As an Expansion Device of Refrigerator)

  • 조병옥
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.1-8
    • /
    • 2000
  • Spray as a liquid atomization technique has wide applications of combustion, painting, chemical, medical and agricultural purpose, and so on. Capillary tubes and expansion valves, as an expansion device of vapor compression type refrigerators, has been used from the early time. But there are some problems in practice, the former can't control refrigerant flowrate exactly and the later most of imported are expensive relatively and has some difficulties to install. Choosing an injector as a new concept of expansion device of refrigerator in this study to improve such troubles of the coming expansion device, the refrigerant spray behavior and refrigeration characteristics are evaluated experimentally. It is verified that the injector with a good function of refrigerant atomization plays a desirable role of refrigerant expansion in the actual refrigeration cycle.

  • PDF

Vuilleumier 사이클로 작동되는 열구동 냉동기의 예비설계조건 (Preliminary Design Conditions for a Thermally Actuated Refrigerator Based on the Vuilleumier Cycle)

  • 유호선;강병하
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2358-2367
    • /
    • 1992
  • 본 연구에서는 그 기초단계로서 작동유체의 실제상태변화에 근접하면서 간편 한 근사적인 단열해석법을 적용하여 VM사이클의 구체적인 예비설계조건을 제시하고자 한다.

GM냉동기를 이용한 수소액화 시스템의 액화량 예측 (Prediction of liquid amount in hydrogen liquefaction systems using GM refrigerator)

  • 박대종;장호명;강병하
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.349-358
    • /
    • 1999
  • Thermodynamic cycle analysis has been performed to maximize the liquid amount for various hydrogen liquefaction systems using GM(Gifford-McMahon) refrigerator. Since the present authors' previous experiments showed that the liquefaction rate was approximately 5.1mg/s in a direct contact with a commercial GM refrigerator, the purpose of this study is to predict how much the liquefaction rate can be increased in different configurations and with improved heat exchanger performance. The optimal operating conditions have been analytically sought with real properties of normal hydrogen for the single-stage GM precooled L-H(Linde-Hampson) system, the two-stage GM direct contact system, the two-stage GM precooled L-H system and the two-stage helium GM-JT (Joule-Thomson) system. The maximum liquefaction rate has been predicted to be only about 7 times greater than the previous experiment, when the two-stage precooling is employed and the effectiveness of heat exchangers approaches to 99.0%. It is concluded that the liquefaction rate is limited mainly by the cooling capacity of the current GM refrigerators and a larger scale of hydrogen liquefaction is possible with a greater capacity of cryocooler at 60-70 K range.

  • PDF

Effectiveness analysis of pre-cooling methods on hydrogen liquefaction process

  • Yang, Yejun;Park, Taejin;Kwon, Dohoon;Jin, Lingxue;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.20-24
    • /
    • 2020
  • The purpose of this analytic study is to design and examine an efficient hydrogen liquefaction cycle by using a pre-cooler. The liquefaction cycle is primarily comprised of a pre-cooler and a refrigerator. The fed hydrogen gas is cooled down from ambient temperature (300 K) to the pre-cooling coolant temperature (either 77 K or 120 K approximately) through the pre-cooler. There are two pre-cooling methods: a single pre-coolant pre-cooler and a cascade pre-cooler which uses two levels of pre-coolants. After heat exchanging with the pre-cooler, the hydrogen gas is further cooled and finally liquefied through the refrigerator. The working fluids of the potential pre-cooling cycle are selected as liquid nitrogen and liquefied natural gas. A commercial software Aspen HYSYS is utilized to perform the numerical simulation of the proposed liquefaction cycle. Efficiency is compared with respect to the various conditions of the heat exchanging part of the pre-cooler. The analysis results show that the cascade method is more efficient, and the heat exchanging part of the pre-coolers should have specific UA ratios to maximize both spatial and energy efficiencies. This paper presents the quantitative performance of the pre-cooler in the hydrogen liquefaction cycle in detail, which shall be useful for designing an energy-efficient liquefaction system.

스크롤기구를 적용한 신형식 스털링 엔진 (New-Type Stirling Engine Employing the Scroll Mechanism)

  • 김영민;신동길;이장희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1709-1716
    • /
    • 2003
  • Stirling engine is a heat engine with a high potential efficiency, multi-fuel capability, its low emission, quiet operation, very low maintenance requirement and long life. The Stirling cycle can ideally achieve optimum thermodynamic efficiency of the Carnot cycle. But the actual efficiency of practical reciprocating Stirling engine is much less than that of ideal Stirling cycle due to several mechanical limits. This paper presents a new-type Stirling engine employing the scroll mechanism superior to the reciprocating Stirling engine. The new-type Stirling engine is characterized as traits of continuous and wholly seperated compression and expansion, one-way flow, direct cooling and heating through the extensive surfaces of scroll wraps. By means of this traits, the new-type Stirling engine can achieve thermodynamic cycle closer to the ideal Stirling cycle and have many mechanical merits. Also, the new-type Stirling cycle can be applied as Stirling refrigerator and Duplex Stirling machine.

  • PDF

단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle)

  • 송영승;정해원;윤원재;김용찬
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.