• Title/Summary/Keyword: Refrigerator Fan

Search Result 57, Processing Time 0.029 seconds

Development of an axial flow fan for a refrigerator by in-house design system (팬 설계 시스템에 의한 냉장고용 축류팬 개발)

  • 최동규;최원석;박성관
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 1997
  • An axial flow fan design system has been made by integrating the self-developed programs and I-DEAS. By using the system, an axial flow fan was designed, manufactured and verified through the wind tunnel experiments in coorperation with a refrigerator appliance division. It has been shown that the optimal design without the ambiguity of the design parameters can be possible by the three-dimensional flow simulations using a self-developed CID code, FANS-3D. (Flow Analysis code using Navier Stokes aguations in Three-Dimensional curvilinear coordinates). By virtue of the fluency of the data flow, an optimally designed fan which satisfies design conditions can be selected in a short time and less cost. The manufacturing processes of a Mock-up and an injection molding die have been automated through the self-made interface programs which connnect from the start to the end. It has been shown that the newly developed fan by this system has a superior performance characteristics to an existing fan.

  • PDF

Acoustic Noise Source Identification and Analysis of Dynamic Characteristics Parameters In BLDC Fan Motor (BLDC Fan Motor의 소음원 규명 및 동특성 분석)

  • Shin, Hyoun-Jeong;Lee, En-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1397-1402
    • /
    • 2013
  • This study researched cause of resonance noise for BLDC motor used in the refrigerator. it is difficult to measure dynamic characteristics for small sized fan & rotor system with conventional excitation method. Therefore this study performed electric exiting method and natural frequency method using microphone instead of conventional excitation and showed validity of these methods. Study result showed that tortional vibration frequency of fan & rotor system and natural bending frequency of the fan were matched with exciting frequency of BLDC motor caused by commutating ripple torque. And this frequency match caused resonance of the system. The study analyzed main parameters of this phenomenon and suggested alternative solution.

Numerical Analysis of Fluid Flow in Freezer Duct of Refrigerator (냉장고의 냉동실내 냉기 덕트 내부의 유동해석)

  • 엄윤섭;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.509-514
    • /
    • 2000
  • A numerical study has been performed to design duct parameters in the freezer of a domestic refrigerator. The visualization results of FDM analysis using the standard k-$\varepsilon$ model with inlet boundary conditions modelled in this paper show good agreements with the experimental ones in prediction overall flow characteristics. Dominant vortex flows are found in the left upper and right lower corners, while there exists large turbulent kinetic energy around the fan and right upper side of the fan. It, in turn, has effects on the performance and noise. It is recommended to locate the outlet far away from the fan in order to reduce the noise level.

  • PDF

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

Development of High-performance/low-noise Centrifugal Fan Circulating Cold Air Inside a Household Refrigerator by Reduction of Vortex Flow (와류 저감을 통한 냉장고 냉기순환용 고성능/저소음 원심홴의 개발)

  • Shin, Donghui;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-Hoon;Jung, Jiwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.428-435
    • /
    • 2016
  • In this paper, high-performance and low-noise centrifugal fan used to circulate cold air inside a household refrigerator is developed by reducing the vortex flow observed near the tip of fan hub. First, the performance of the existing centrifugal fan is investigated through the experiment using a fan tester and the characteristics of detailed flow field obtained from the CFD simulation are closely examined. The strong vortex flow is observed in the vicinity of the tip of fan hub. Based on this result, new design is devised to reduce this vortex flow. As a result, it is numerically and experimentaly found that the volume flow rate of the new fan increases and the radiated noise decreases in comparison with the existing fan at the same rotation speed.

Study on the Noise Reduction of BLDC Fan Motor by Cogging Torque Reduction (코깅토크 저감에 의한 BLDC Fan & Motor의 공진 소음 개선에 관한 연구)

  • Shin, Hyoun-Jeong;Lee, En-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1217-1222
    • /
    • 2013
  • It is very important to diminish noise source of electric motor systems that are used for home appliance area. We have studied on the noise reduction of BLDC motor, mainly focusing on reducing noise source from cogging torque. This noise source causes resonance of fan & motor systems. This study showed that the higher harmonic component of the cogging torque was the main factor for noise generation. Therefor, to reduce noise of bldc motor for refrigerator, this study suggested peanut shaped magnet which surface flux has similar sinusoidal wave form.

Prediction of Internal Broadband Noise of a Centrifugal Fan Using Stochastic Turbulent Synthetic Model (통계적 난류합성 모델을 이용한 원심홴 내부 광대역 소음 예측)

  • Heo, Seung;Kim, Dae-Hwan;Cheong, Cheol-Ung;Kim, Tae-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1138-1145
    • /
    • 2011
  • The internal broadband noise of a centrifugal fan in a household refrigerator is predicted using hybrid CAA techniques based on stochastic turbulent synthetic model. First, the unsteady flow field around the centrifugal fan is predicted using computational fluid dynamics(CFD) method. Then, the turbulent flow field is synthesized by applying the stochastic turbulent synthetic technique to the predicted flow field. The aerodynamic noise sources of the centrifugal fan are modeled on a basis of the synthesized turbulent field. Finally, the internal broadband noise of the centrifugal fan is predicted using the boundary element method(BEM) and the modeled sources. The predicted noise spectrum is compared with the experimental data. It is found that the predicted result closely follows the experimental data. The proposed method can be used as an effective tool for designing low-noise fans without expensive computational cost required generally for the LES and DNS simulations to resolve the turbulence flow field responsible for the broadband noise.

Computation of Internal BPF Noise of Axial Circulating Fan in Refrigerators (냉장고 내 냉기순환용 축류홴에 의한 내부 블레이드-통과-주파수 소음 예측)

  • Lee, Seung-Yub;Heo, Seung;Cheong, Cheol-Ung;Kim, Seok-Ro;Seo, Min-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.5
    • /
    • pp.454-461
    • /
    • 2009
  • Internal aeroacoustics of an axial fan used for circulating cold air in refrigerators are computed by using the hybrid method where CFD, acoustic analogy and BEM techniques are utilized. The unsteady flow field around the axial fan is predicted by solving the incompressible RANS equations with the conventional CFD techniques. Then, main noise sources are extracted from this unsteady flow field predictions using Acoustic Analogy. Lastly, BPF noise generated from an axial fan are predicted using these modeled sources combined with the tailed Green function techniques, which are numerically solved by the BEM technique. This hybrid model is validated by comparing the prediction with the experiment. Then, parameter studies are carried out, which suggest a capability of the current method as a design tool for the low-noise of the current axial fan system in a refrigerator.

Prediction of internal broadband noise of a centrifugal fan using stochastic turbulent synthetic model (통계적난류합성모델을 이용한 원심홴 내부 광대역 소음 예측)

  • Heo, Seung;Kim, Dae-Hwan;Cheong, Cheol-Ung;Kim, Tae-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.627-632
    • /
    • 2011
  • The internal broadband noise of a centrifugal fan in a household refrigerator is predicted by using hybrid CAA technique based on stochastic turbulent synthetic model. First, the unsteady flow field around the centrifugal fan is predicted using Computational Fluid Dynamics (CFD) method. Then, the turbulent flow field is synthesized by applying the stochastic turbulent synthetic technique to the predicted flow field. The aerodynamic noise sources of the centrifugal fan are modeled on a basis of the synthesized turbulent field. Finally, the broadband noise of the centrifugal fan is predicted using Boundary Element Method (BEM) and the modeled sources. The predicted result is compared with the experimental data. It is found that the predicted result closely follows the experimental data. The proposed method can be used as an effective tool for designing low-noise fans without expensive computational cost required generally for the LES and DNS simulations to resolve the turbulence flow field responsible for the broadband noise.

  • PDF

3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator (냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I))

  • Oh, Min-Jung;Lee, Jae-Heon;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF