• Title/Summary/Keyword: Refrigerator's compressor

Search Result 27, Processing Time 0.023 seconds

Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators (프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구)

  • Lim, B.H.;Park, Y.B.;Yoo, H.K.;Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

Design Optimization of a Compressor Loop Pipe using Response Surface Method (반응표면법을 이용한 압축기 루프 파이프의 최적 설계)

  • 강정환;박종찬;김좌일;왕세명;정충민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.404-409
    • /
    • 2004
  • A compressor loop pipe is the most important part in a refrigerator from the view of structural vibration and noise. Vibration energy generated from a compressor's inner body is transmitted to the shell and outside through the loop pipe. For this reason it is very important to design a compressor loop pipe. But, for geometrical complexity and dynamic nonlinearity of the loop pipe, analysis and design of the loop pipe is very difficult. So the statistical and experimental methods have to be used for design of this system. The response surface method (RSM) becomes a popular meta-modeling technique f3r the complex system as this loop pipe. As starting point of loop pile's optimization, FEA model and simple experimental model are used instead of the real loop pipe model. After RS model was constructed, using sensitivity-based optimizer performed optimization for the loop pipe. And the moving least square method (MLSM) was applied to reduce the approximation error.

  • PDF

Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under High Temperature - (냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 고온 가혹조건에서의 가속계수와 단축 시험기간 -)

  • Jung, Y.M.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.44-50
    • /
    • 2012
  • The reliability qualification test is essential in order to ensure the life time of the product under the normal operation conditions when a new product is developed. The reliability qualification test period has an important impact on the development time of new product. Therefore, some researches to reduce the test time of reliability qualification test have been actively studied. Generally, accelerated life test is well known as one method that can save the test time of the reliability qualification test. This test is conducted under the higher stress condition than normal condition. So we need to investigate what factor affects to the higher stress condition. This paper shows the relationship between the acceleration factor and reliability qualification test period. Especially, we focused on the method to obtain effective acceleration factors under the high temperature condition. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under Low Temperature - (냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 저온 가혹조건에서의 가속계수와 단축 시험기간 -)

  • Jung, Y.M.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-48
    • /
    • 2012
  • Generally accelerated life test is well known as one method to reduce reliability qualification test period. This test is conducted under the higher stress condition than normal condition. So it can save the test time by calculating the acceleration factor from the relationship between the worst stress condition and normal condition. This paper investigates the worst stress condition for the accelerated life test to increase the acceleration factor. Especially, we focused on the method to obtain effective acceleration factors under the worst stress condition. Moreover, we considered how to decide the worst stress condition by looking for the operating limit of this system. The acceleration factor can be estimated from the ratio of the kinematic viscosity in the normal condition and the worst stress condition, the lowest temperature, by using Arrhenius relationship. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Performance of Refrigerator Using R134a, R152a and R22/142b (R134a, R152a, R22/142b를 이용한 냉동기의 성능실험)

  • Chang, Y.S.;Shin, J.Y.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.39-46
    • /
    • 1994
  • Experiments on the performance of refrigeration system using alternatives to R12 are carried out. The condenser and the evaporator are concentric-tube heat exchangers of counter-flow type and the compressor is driven by a variable speed motor. In this study, R134a, R152a, R22/142b(50 : 50 by mass) are adopted as alternatives to R12. Tests are performed by varying the inlet and outlet temperatures of secondary fluids of evaporator and condenser under the condition of constant compressor speed, degree of superheating and degree of subcooling. Results show that R134a has refrigeration capacity close to that of R12 and requires the greatest compressor power compared with that of others. And the system using R152a shows the best performance from the viewpoint of refrigeration capacity, compressor power and coefficient of performance. R22/142b is superior to R12 in the above points.

  • PDF

Development of Sound Quality Evaluation Technique for a Refrigerator under Household Usage Environment (실환경에서의 냉장고 음질 평가 기법 개발)

  • Kim, Sang-Soo;Lee, Eun-Young;Kim, Jung-Rae;Kim, Jong-Yeob;Lee, Dong-Hyun;Oh, Jong-Hak
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.427-430
    • /
    • 2005
  • The quality of various noises generated in the refrigerator is one of the important factors in deciding quality of the product. The main focus of sound control design has been shifted from reduction of sound level to improvement of sound duality for customer's preference. Up to date the purpose of noise control is the minimization of noise level. However despite of gradual decrease of noise level, occasionally the perceptional quality of noise has not been improved. In this paper, the relation between subjective and objective evaluation of sound quality has established and sound quality index is developed using ANN for evaluation of refrigerator's noise of both the starting noise and the stable running noise of compressor. To verify the usefulness of the index, the results in this paper have been compared with those surveyed by Consumer Union in USA.

  • PDF

Analytical Study of Cooling Performance Comparison in a Refrigerator Truck Using R404A and R744 (R404A와 R744의 냉매를 이용한 냉동탑차 냉장성능 비교에 관한 해석적 연구)

  • Myung, Chi-Wook;Kim, Sang-Hun;Cho, Hong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.119-125
    • /
    • 2011
  • The analysis of performance characteristics in a refrigerator truck using R404A and R744 was carried out by using theoretical method, and each performance was compared with a variation of operating conditions. The components and cycle simulation model were developed by using EES program. To investigate the performance characteristics with operating conditions, the performance of both systems was simulated according to indoor temperature, outdoor temperature, outdoor air velocity and compressor speed. As a result, the R744 system had a better COP than R404A system for given operating condition. The cooling capacity was not increased over the outdoor air velocity of 3 m/s. Besides, the performance of R404A system was more sensitive to operating conditions compared to that of R744 system.

Investigation on feasibility of pulse tube engine (맥동관 엔진의 구현 가능성에 대한 연구)

  • Ki, T.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.34-37
    • /
    • 2012
  • In this paper, configurations and performance of a pulse tube engine (PTE) are investigated. The configuration of PTE is basically designed by using a concept of energy flow. The configurations of PTE are classified as a PTE with two pistons and a PTE with one piston. First, the PTE with two pistons is simulated and the Carnot efficiency is about 41 %. The phase difference of between motion of two pistons located at expander and compressor mainly effects the performance of the PTE. Second, the PTE with one piston is designed. From a concept of analogy, the piston of compressor is replaced by a compliance tube and a resonator. The PTE with one piston is identical with a thermoacousic engine and has the large volume because the compliance tube and resonator are consisted of large volume tubes. Therefore, we will consider each usefulness of the compact PTE with two pistons and the huge PTE with one piston for PTE applications and the judgement of feasibility.

Condition Classification for Small Reciprocating Compressors Using Wavelet Transform and Artificial Neural Network (웨이브릿 변환과 인공신경망 기법을 이용한 소형 왕복동 압축기의 상태 분류)

  • Lim, D.S.;Yang, B.S.;An, B.H.;Tan, A.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.29-35
    • /
    • 2003
  • The monitoring and diagnostics of the rotating machinery have been received considerable attention for many years. The objectives are to classify the machinery condition and to find out the cause of abnormal condition. This paper describes a classification method of diagnosing the small reciprocating compressor for refrigerators using the artificial neural network and the wavelet transform. In order to extract salient features, the wavelet transform are used from primary noise signals. Since the wavelet transform decomposes raw time-waveform signals into two respective parts in the time space and frequency domain, more and better features can be obtained easier than time-waveform analysis. In the training phase for classification, self-organizing feature map(SOFM) and learning vector quantization(LVQ) are applied, and the accuracies of them ate compared with each other. This paper is focused on the development of an advanced signal classifier to automatize the vibration signal pattern recognition. This method is verified by small reciprocating compressors, for refrigerator and normal and abnormal conditions are classified with high flexibility and reliability.

  • PDF

A Study on The Drying and Hot Water System Using Condensation Waste Heat (응축폐열을 이용한 건조 및 온수장치에 관한 연구)

  • Park N. H.;Koh H. Y.;Jeong J. W.;Kang T. S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF