• Title/Summary/Keyword: Refrigeration ability

Search Result 24, Processing Time 0.031 seconds

Thermal stability, magnetic and magnetocaloric properties of Gd55Co35M10 (M = Si, Zr and Nb) melt-spun ribbons

  • Jiao, D.L.;Zhong, X.C.;Zhang, H.;Qiu, W.Q.;Liu, Z.W.;Ramanujan, R.V.
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1523-1527
    • /
    • 2018
  • The thermal stability, magnetic and magnetocaloric properties of $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) melts-pun ribbons were studied. The relatively high reduced glass transition temperature ($T_{x1}/T_m$ > 0.60) and low melting point ($T_m$) resulted in excellent glass forming ability (GFA). The Curie temperatures ($T_C$) of melt-spun amorphous ribbons $Gd_{55}Co_{35}M_{10}$ for M = Si, Zr and Nb were 166, 148 and 173 K, respectively. For a magnetic field change of 2 T, the values of maximum magnetic entropy change $(-{\Delta}S_M)^{max}$ for $Gd_{55}Co_{35}Si_{10}$, $Gd_{55}Co_{35}Zr_{10}$ and $Gd_{55}Co_{35}Nb_{10}$ were found to be 2.86, 4.28 and $4.05J\;kg^{-1}K^{-1}$, while the refrigeration capacity (RC) values were 154, 274 and $174J\;kg^{-1}$, respectively. The $RC_{FWHM}$ values of amorphous alloys $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) are comparable to or larger than that of $LaFe_{11.6}Si_{1.4}$ crystalline alloy. Large values of $(-{\Delta}S_M)^{max}$ and RC along with good thermal stability make $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) amorphous alloys be potential materials for magnetic cooling operating in a wide temperature range from 150 to 175 K, e.g., as part of a gas liquefaction process.

Development of a Simulation Model for Separation Analysis and Design of Star Screen in Construction Wastes Recycling (건설폐기물 선별 해석을 위한 치차형 스크린 해석모델 개발)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Moon, Byung-Young;Park, Yong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.213-218
    • /
    • 2010
  • In this study, a star screen model was constructed to predict the dynamic characteristics of interactive waste particles and to simulate separation capability of the particle using geared type screen(star screen). In order to approach this model, it is necessary to determine the design parameters of the screen such as driving torque, percentage of open space, and capability. Thus, a dynamic star screen model was developed with a total of 32 columns of geared assembly including screen part, wastes guide, and extra joints to rotate the screen using ADAMS. Each parameter was simulated to predict the screening capability for particle size, rotating speed, and particle condition. From the results, separation ability was predicted according to the affecting variables by using the dynamic star screen model.

The Experimental Study on a Effect of Korean Paper (Hanji) on Indoor Humidity Control (한지(韓紙)가 실내습도조절에 미치는 영향에 관한 실험적 연구)

  • 이종원;임정명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.599-607
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as an architectural material. Hanji has good things in controlling indoor space comfortably. Particularly, ability of controlling humidity of Hanji affects indoor space comfort and human health. The major focuses of this experimental research are (1) how much of water vapor passes through Hanji, (2) how much of water vapor is absorbed into Hanji. In the first case, indoor humidity is higher than outdoor humidity. In this case, approximately 38 g of water vapor passes through Hanji 1, genarally utilized in window paper (Changhoji), per square meter in one hour. And approximately 4 g of water vapor is absorbed into Hanji 2, genarally utilized in wallpaper, per square meter. In the second case, outdoor humidity is higher than indoor humidity. In this case, Hanji passes water vapor to inner space at first, but when indoor relative humidity reach approximately 66%, although outdoor humidity is higher than indoor humidity, water vapor doesn't pass through Hanji. If Hanji is utilized in window material and wallpaper, indoor space is maintained comfortably without mechanical devices in humidity control.

The Study on Drag Reduction Rates and Degradation Effects in Synthetic Polymer Solution with Surfactant Additives (계면활성제를 이용한 합성고분자 수용액의 마찰저항감소 및 퇴화 특성 향상 연구)

  • 이동민;김남진;윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • The turbulent flow resistance of water solution with polymer is reduced as compared with that of pure water. This effects is named th drag reduction and offers the significant reduction of the pumping power and the energy consumption. But the intense shear forces and the high temperature experienced by the polymer solution when passing through the pipes cause the degradation a loss of drag reduction effectiveness. Especially, the degradation behavior is found to be strongly dependent on temperature. This mechanical and thermal degradation can be avoided by adding materials such as surfactant to the polymer solution, which enhance the bonding force between molecules. In the present study, Copolymer and SDS were utilized and they were mixed in 10 different mixture ratios, while total concentration was fixed as 100wppm. Degradation of Copolymer-SDS mixture solutions was investigated experimentally in closed loop at the temperature of $10^{\circ}C\; and\; 80^{\circ}C$ with various flow average velocities of 1.5 m/sec, 3.0m/sec, and 4.5m/sec. Degradation characteristics of polymer solution without surfactant show a radical loss of drag reduction effectiveness at high temperature. Degradation alleviation ability of surfactant is especially effective at high temperature. Consequently, this results show that the addition of surfactant to the polymer solution can control unfavorable degradation phenomena for high temperature systems.

  • PDF

An Experimental Study on the Combustion Characteristics with Superadiabatic Combustor in Porous Media (다공성물질을 이용한 초단열 연소장치에서의 연소특성의 실험적 연구)

  • Chae, J.O.;Dobrego, K.V.;Sim, M.S.;Chung, S.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.399-405
    • /
    • 1994
  • Beacuse of the energy resources exhaustion, the aggravating environmental air pollution and the smoke phenomena etc., the importance of clean gas fuel compared with liquid fuel is highly considered in recent years. The combustion system which consists of porous media is actively studied as a new method for solving above problems. Therefore, excess enthalpy combustion using porous media was interested by many researchers and investigated through numerical and experimental analysis. In this study, the simplified combustor has the unique combustion characteristics of mixture gas preheated effect using radiative and convective heat energy by changing the flow passage of unburned gas with solenoid valves and has the intensive excess enthalpy phenomena As the result of according to reduce equivalence ratio, flame temperature was remarkably higher than adiabatic flame temperature. This show the ability of super-lean combustion.

  • PDF

Optimum Management Plan of the HVAC Equipments with LCC Analysis (LCC 분석을 통한 공기조화 열원설비의 최적 관리방안)

  • Kim, Yong-Ki;Woo, Nam-Sub;Kang, Sung-Ju;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.556-562
    • /
    • 2008
  • The building HVAC systems have very different qualities of performance and durability with the superintendent's ability for management and maintenance. The poor management of these systems finally lead to the shortening of the life expectancy and result in the increase of operating costs and energy consumptions due to low efficiencies. This study presents an example of appropriate use of the LCC(Life Cycle Cost) analysis in a process of maintaining and repairing old HVAC equipments, by demonstrating the difference of optimal economic life, decrease of running cost, and energy consumption according to the management level of the HVAC equipments. But there are no reliable life expectancy and performance history data at present for optimal management of various building service equipments. Therefore, it is necessary to construct long-term database on operation results of them for more accurate and optimized LCC analysis.

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Experimental Study on the Heat Distribution in the Rectangular Mini Channel Heat Exchangers with MPCM Slurry (마이크로 캡슐 잠열재 슬러리를 적용한 미소채널 열교환기의 열분배 성능평가)

  • Jeon, Jong-Ug;Back, Chang-Huyn;Kim, Yong-Chan;Kim, Young-Deug;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.645-650
    • /
    • 2006
  • The heat transfer performance and energy transport ability are relatively high due to higher specific heat. Therefore, it can be used in fields such as heating, ventilating, air-conditioning, refrigeration and heat exchangers. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, liquid-cooling heat exchangers were tested to provide performance data for MPCM slurry. The liquid-cooling heat exchangers had twelve rectangular channels with flow paths of 1, 2, 4 and 12. Silicon rubber heaters were used to control the heat load to the heat exchanger. Heat input ranged from 293 to 800 W, and inlet temperatures of working fluid varied from 15S to $27^{\circ}C$. The standard deviation of surface temperature was strongly affected by the coolant of MPCM Slurry, All MPCM-cooling heat exchangers showed higher cooling performance than the water-cooling heat exchanger except one path channel heat exchanger.

  • PDF

Effects of Refrigerant Oils and Molecular Sieve on Air Conditioner using Alternative Refrigerant (대체냉매를 사용한 에어콘에서 합성오일과 건조제(M/S)의 영향)

  • Choa, S.H.;Hong, C.K.;Kim, C.K.;Yoon, B.;Kang, S.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.473-483
    • /
    • 1996
  • To protect the ozone layer, R22 will be replaced with HFCs. R407C is a leading candidate as alternative refrigerant for air conditioner due to its similar thermodynamic characteristics with R22. In replacing R22 with R407C, the compatibility with lubricating oil is of major concern. Polyol ester (POE) oil among the synthetic oils is considered to be the best lubricant for use with R407C because of good electrical properties and miscibility. However, lubricating ability of mixture of R407C/POE oil is lower than that of R22/mineral oil due to the production of acid by hydrolysis which causes corrosive wear. Therefore, to minimize water content, it is needed to develop a molecular sieve desiccant which is compatible with R407C and ester oil. This paper discusses (1) the change of properties of POE oil when current molecular seive is used, (2) the effects of POE oils and additives on durability of compressor. Through compressor life test and bench wear test, it was found that inadequate use of POE oils and additives may promote the deteriation of molecular sieve, resulting in decrease of durability of compressor.

  • PDF