• Title/Summary/Keyword: Refrigeration ability

Search Result 25, Processing Time 0.02 seconds

Analysis of Design Factors for High Performance Fuzzy Logic Control of Refrigeration Cycle (냉동사이클의 고성능 퍼지제어를 위한 설계 인자들의 영향 분석)

  • Choi, Sung-Woon;Jeong, Seok-Kwon;Yang, Joo-Ho
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.11-19
    • /
    • 2016
  • A variable speed refrigeration system(VSRS) has been received high attention for energy saving ability. This paper investigates effects of design factors such as membership function range and sampling time to control performances for systematical designing fuzzy logic controller of the VSRS. Some comparisons of control performance between the fuzzy and PI are conducted including comparative evaluation of robustness against noise by using computer simulations. The simulation results showed that the fuzzy is very useful design method for engineers in the industrial fields which have big noises system and deal with inherent nonlinear system like the VSRS.

Experimental Study on a Rotary Magnetic Refrigeration Device (회전식 자기냉동장치에 대한 실험적 연구)

  • Lee Jong Suk;Hong Jeong Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1101-1106
    • /
    • 2004
  • Magnetic refrigeration is based on the magnetocaloric effect (MCE)-the ability of some materials to heat up when magnetized and cool down when demagnetized. A rotary magnetic refrigeration device using gadolinium (Gd) ribbon and permanent magnets was constructed for experimental study. Gd ribbon attached around a rotating wheel is cyclically magnetized and demagnetized by permanent magnets and exchanges heat with liquid in the surrounding container. Temperature of the liquid in each divided section of the container was measured and the experimental results obtained in this study were discussed.

A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device (냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구)

  • 조병옥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

Performance Estimation of Hybrid Solar Air-Water Heater on Single Working of Heating Medium (복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가)

  • Choi, Hwi-Ung;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.49-56
    • /
    • 2014
  • Research about hybrid solar air-water heater that can make heated air and hot water was conducted as a part of improving efficiency of solar thermal energy. At this experiment, ability of making heating air and hot water was investigated and compared with traditional solar air heater and flat plate solar collector for hot water when air or liquid was heated respectively. Comparing hybrid solar air-water heater that used in this experiment to other solar air heater studied already, it has a lower efficiency at same mass flow rate. Air channel structure, fin's shape and arrangement in the air channel result in these difference then the ability of air heating need to be improved with changing these thing. In case of making hot water, performance was shown as similar with traditional system although the air channels were established beneath absorbing plate. But the heat loss coefficient was shown higher value by installing of air channel. Also the performance of hot water making was shown lower value at same liquid mass flow rate with traditional flat plate solar collector for hot water. So the necessity of performance improvement at lower mass flow rate of each heating medium can be confirmed.

Experimental investigation on the room temperature active magnetic regenerator with permanent magnet array (영구자석 배열을 이용한 능동형 자기재생 냉동기에 대한 실험적 연구)

  • Kim, Young-Kwon;Jeong, Sang-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.186-191
    • /
    • 2008
  • In this study, a room temperature AMRR (Active magnetic regenerative refrigerator) was fabricated, and experimentally investigated. Gadolinium (Gd) was selected as a magnetic refrigerant with Curie temperature of 293 K. Permanent magnet was utilized to magnetize and demagnetize the AMR. To produce large magnetic field above 1 T in the magnetic refrigeration space, a special arrangement of permanent magnets, so called Halbach array, is employed. Sixteen segments of the permanent magnets magnetized different direction, constitute a hollow cylindrical shaped permanent magnet. The AMR is reciprocated along the bore of the magnet array and produces cooling power. Helium is selected as the working fluid and a helium compressor is utilized to supply helium flow to the regenerator. The fabricated AMRR has different structure and compared to a convectional AMRR since it has an additional volume after the regenerator. Therefore, the cooling ability is generated not only by magnetocaloric effect of magnetic refrigerant but also by the pulse tube effect. It is verified that the cooling ability of AMR is increased due to the magnetocalric effect by the fact that the temperature span becomes $16^{\circ}C$ while the temperature span is only $8^{\circ}C$ when the magnetic field is not applied to the regenerator.

  • PDF

Demonstrative Experiments on the Magnetocaloric Effect of Gadolinium (가돌리늄의 자기열량효과에 대한 실증실험)

  • 이종석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.383-389
    • /
    • 2004
  • Magnetic refrigeration is based on the magnetocaloric effect (MCE) - the ability of some materials to heat up when magnetized and cool down when removed from the magnetic field. The available techniques for studying the MCE we: (1) direct measurements by monitoring the change in the material's temperature during the application or removal of the magnetic field; and (2) indirect calculations from the experimental data of magnetization and/or specific heat as a function of the temperature and magnetic field. The MCE of gadolinium (Gd) has been demonstrated by direct measurements of temperature change, and isothermal magnetic entropy changes and adiabatic temperature changes have been calculated.

Dynamic Analysis and Design of Star Screen in Recycling Construction Plant (치차형 스크린의 선별 성능 향상을 위한 동적 해석과 설계 형상 변경)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Moon, Byung-Young;Park, Yong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.219-224
    • /
    • 2010
  • Recycling issue for the construction wastes is gradually important to future society. Recently, a star screen has been developed to use for this purpose, however some modifications were needed to enhance the separation accuracy. The objective of study is to evaluate and predict separation ability by verifying the effect for the modified shapes of the screen part. Two analysis models of the screen part were established using commercial software ADAMS to simulate the dynamic interaction of waste particles. Results showed that spacer and gear shapes directly affected separation ability. The modified spacer shapes were much higher screening rate with comparison to default shape. Screening ability for the half number of gear type was greater than other types. Therefore, modification of the design of screen part will be required to achieve better separation ability.

A study on design for free cooling system using dry cooler (드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구)

  • Yoon, Jung-In;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1027-1031
    • /
    • 2014
  • Free cooling system is used to reduce energy consumption of cooling system. Free cooling system is consisted of cooling group and dry-cooler in which heat exchange of chilled water and out air is conducted. Although this system has an excellent energy saving effect in place having cooling load regularly, data or material of design for free cooling system is lacked. In this study, characteristics analysis of free cooling system is conducted through software HYSYS with changing some facts. The main result is following as : Dry-cooler capacity is influenced by out air temperature, required chilled water temperature and LMTD(Logarithmic Mean Temperature Difference) of heat exchanger. As out air temperature is more low, dry-cooler capacity become increased. in addition, as required chilled water temperature is more high and LMTD is more low, the out air temperature range is widened for using dry-cooler. If out air temperature is below $0^{\circ}C$, antifreeze need to be used because freeze and burst can be occurred. In case of South Korea, antifreeze of 34% of ethylene glycol concentration is proper. When compressor load of R22, R134a and R407C is compared, considering environmental regulation and energy consumption, R134a is best working fluid.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

A Study Basic Engineering for Improving the Creative Practice PBL Case (기초 공학의 창의적인 실습 능력 향상을 위한 PBL 적용 사례 연구)

  • Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5396-5402
    • /
    • 2013
  • In this study, one for grades 1 Institute of Foundation Engineering Practice training to enable the creativity of problem-based learning as an alternative (PBL: Problem-Based Learning) training system was applied. The reason for the development of education systems engineering knowledge and practice skills related to the University no basis for first year students in the theory and practice based on the characteristics of the materials used and the tools to use, how to use the machine was to be accomplished. Hands-on training for existing structured learning plan driven by the faculty and students conducted hands-on training in the uniform limits on the ability of the practice has been shown. However, in this study on the basis of PBL learning materials, and the students themselves leading learner-centered practice problems derive and small unit exercises the ability to decide how to proceed on improving the educational process proposes. As a result of these studies, about 30% more than traditional hands-on training to improve the ability of learning respectively.