• Title/Summary/Keyword: Refrigeration Cycle

Search Result 445, Processing Time 0.024 seconds

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

Performance Test of a R134a Centrifugal Water Chiller

  • Jeong, Jin-Hee;Yoon, Pil-Hyun;Kim, Ghil-Yeung;Lee, Hyeon-Koo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • A centrifugal water chiller using alternative refrigerant R134a has been developed. The prototype was designed to have refrigerating capacity of 300RT. Its compressor employs a single high-speed impeller, airfoil diffuser and collector. Newly developed, enhanced tubes were installed in the evaporator and the condenser to reduce the required head for the compressor. Off-design characteristics at various conditions, performance test of the compressor and analysis of the refrigeration cycle were performed. So the probability of use in part load condition was checked and the direction for revision was suggested.

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

State Monitoring of Compressor using AE Signal in Life Test (압축기의 수명실험에서의 AE 신호를 이용한 상태감시)

  • 정지홍;강명창;노태영;이감규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.56-60
    • /
    • 1997
  • The compressor is one of important elements in refrigeration cycle and play an important role of refrigeration efficiency and quality. This paper analyzes slides in rotary compressors for room air conditioners, monitoring using Acoustic Emission(AE) technique. Reliability of rotary compressors which are factory-tested has been evaluated through visual inspection on taking them apart after long term test, which is life test. This paper describes methods for acquisition and processing of Acoustic Emission(AE) raw signal to monitor state of rotary compressor in Life Test.

  • PDF

The Abnormal Condition Monitoring of Rotary Compressor using Acoustic Emission (AE 신호를 이용한 회전형 압축기의 이상상태 감시)

  • Lee Kam-Gyu;Jung Ji-Hong;Kim Jeon-Ha;Kang Myung-Chang;Kim Jeong-Suk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.118-123
    • /
    • 2004
  • The compressor has one of important roles in refrigeration cycle and it determines refrigeration efficiency and quality This paper aims to monitor rotary compressors for room air conditioners by using Acoustic Emission(AE) technique. The reliability of rotary compressors has been evaluated through visual inspection on them after long term test. This paper describes methods for acquisition and processing AE raw signal to monitor the state of rotary compressor. A detecting method of abnormal compressor in real time is suggested and special-purpose monitoring system which can be applied to automatic manufacturing line is developed using one-chip microprocessor at low cost.

Simulation of Alcohol Absorption Heat Pumps for Heating Performance (알코올 흡수식 열펌프의 난방성능 예측)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.269-276
    • /
    • 2015
  • Single-effect $CH_3OH-LiI-ZnBr_2$ and $C_2H_5OH-LiI$ absorption heat pumps are simulated to evaluate feasibility as heating device. These systems are predicted to give higher heating COPs in wide operating ranges compared to conventional systems. Among the two systems, the $C_2H_5OH-LiI$ system is found to be more advantageous for operating in extremely cold weather due to the large solubility of Lil in $C_2H_5OH$.

Estimation of characteristic parameters of refrigerants by group contribution method (집단 기여법에 의한 냉매의 특성인자 예측)

  • Kim, Y.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.125-132
    • /
    • 1999
  • Studies are being done to replace conventional refrigerants with alternatives that have low or no ozone depletion and greenhouse warming Potentials, yet possess appropriate pro perties for a refrigeration cycle. To achieve this goal, a consistent set of thermodynamic properties of the working fluid is required. A common problem with the possible alternative refrigerants is that sufficient experimental data do not exist, thus making it difficult to develp complete equations of state that can predict properties in all regions including the vapor-liquid equilibrium. One solution is the use of the generalized equation of state correlations that can predict thermodynamic properties with a minimum number of characteristic parameters. Characteristic parameters required for the generalized equation of state are, in general, critical temperature, critical pressure, critical volume and normal boiling temperature. In this study, estimation of these characteristic parameters of refrigerants by group contribution method is developed.

  • PDF

A Performance test of Stirling Cryocooler by Frequency Characteristics (스터링 냉동기의 주파수 특성에 의한 성능평가에 관한 연구)

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Go, Deuk-Yong;Go, Gun-Seop;Kim, Jong-Hak
    • 연구논문집
    • /
    • s.30
    • /
    • pp.25-32
    • /
    • 2000
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. The FPFD Stirling cryocooler employs 1) the Stirling cycle for refrigeration, 2) linear for driving the cryocooler, 3) spring and gas support systems, and 4) fine gap for clearance seals. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. In order to get optimum operating frequency, natural frequency of piston and displacer, optimum phase angle between piston and displacer, cooling capacity, performance tests of the Stirling cryocooler by the frequency characteristics were performed.

  • PDF

Analysis of Oil Behavior inside Rotary Compressor Using Developed Visualization Technique

  • Cho Pil-Jae;Lee Seung-Kap;Youn Young;Ko Han-Seo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.76-83
    • /
    • 2006
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured. in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using a manufactured test model.

Adiabatic Analysis of Stirling Refrigerator with Real Gas Properties (실제기체의 물성을 이용한 Stirling 냉동기 단열해석)

  • Baik, J.H.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.150-160
    • /
    • 1995
  • A Finkelstein adiabatic analysis is performed for Stirling refrigerator with real gas properties of helium. The mass balance and the energy balance equations are formulated into the form that is convenient for incorporating an available computer code of the helium properties. The differential equations are solved numerically. The calculated coefficient of performance(COP) and the pressure variation are compared with the results obtained when helium is assumed to be an ideal gas. The relative errors in COP are presented as functions of the refrigeration temperature and the maximum cycle pressure.

  • PDF