• Title/Summary/Keyword: Refrigerating capacity

Search Result 497, Processing Time 0.025 seconds

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Performance Characteristics with Capacities of Heat Exchangers of a Refrigeration System (열교환기 전열용량이 냉동시스템의 성능에 미치는 영향)

  • 김제봉;김수연;정평석;조경철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.187-195
    • /
    • 2003
  • The geometric size and the refrigeration capacity of a refrigeration system are strongly dependent on the capacity of heat exchanger, which is one of the key design parameters. In this paper, the effect of the capacities of heat exchangers on the performance of a real refrigeration system operated in a vapor compression cycle was analyzed by the numerical simulation. From the results, the conditions that gave the maximum values of the refrigeration capacity or COP were respectively determined as a function of the capacities of condenser and evaporator under the given ambient and operating condition.

Design and Analysis of Fuzzy Control in a Variable Speed Refrigeration System

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • This paper deals with fuzzy control with a feedforward compensator to progress both energy saving and coefficient of performance (COP) in a variable speed refrigeration system. Both the capacity and superheat are controlled simultaneously and independently in the system. By adopting the fuzzy theory, the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can reduce influence of the interfering loop between the capacity and superheat. Some experiments are conducted to design appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system in spite of its inherent strong non-linearity. Also, the fuzzy control performances were investigated by comparing to the model based PI control experimental results to evaluate transient behavior under the control.

An Experimental Study of Adsorption Chiller using Silica gel-Water (실리카겔-물계 흡착식 냉동기에 관한 실험적 연구)

  • Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Joung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1119-1124
    • /
    • 2006
  • The objectives of this paper are to investigate the performance of silica gel-water adsorption refrigeration system with heat recovery process from the system experiment. This system can be driven by waste heat at near ambient temperature from $60^{\circ}C$ to $90^{\circ}C$. The cooling capacity and coefficient of performance(COP) were measured from various experimental conditions. An experimental results revealed the influence of operating temperatures(hot, cooling and chilled water), water flow rates, and adsorption-desorption cycle times on cooling capacity and COP. Under the standard conditions of $80^{\circ}C$ hot water, $25^{\circ}C$ cooling water, $14^{\circ}C$ chilled water inlet temperatures and 420sec cycle time, a cooling capacity of 1.14kW and a COP for cooling of 0.55 can be achieved.

  • PDF

A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat (증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구)

  • 김재돌;오후규;윤정인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.