Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.

Test Results of Refrigerant R152a in a Mobile Air-Conditioning System

  • Shin, Jeong-Sub;Park, Won-Gu;Kim, Man-Hoe
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.44-50
    • /
    • 2008
  • This study presents test results of a mobile air-conditioning system using a potential alternative refrigerant, R152a. A series of performance tests have been carried out and cycle characteristics such as cooling capacity, energy efficiency ratio, suction and discharge pressures, and temperatures are presented, compared to those for the baseline R134a system. Tests were conducted with evaporation temperature of $5^{\circ}C$, condensation temperature of $45^{\circ}C$, subcooling temperature of $5^{\circ}C$, superheating temperature of $5^{\circ}C$, and compressor speed of 500-1500 rpm. The performance of R152a system with readjustment of an expansion valve showed better than those of R134a. The effect of oil on the pressure drop in the evaporator was also addressed.

Performance Simulation of a R744 Refrigeration System in a Refrigerator Truck under a Frost Condition (착상조건에서 R744 냉매 적용 탑차용 냉장시스템의 성능해석)

  • Kim, Sang Hun;Myoung, Chi Wook;Cho, Hong Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.499-505
    • /
    • 2013
  • R744 has been appropriated for substitute refrigerant, because of its high stability, and environment-friendly nature as a natural refrigerant. To analyze the cooling performance of a refrigeration system in a refrigerator truck using R744 according to the blocking ratio, an analytical model of the refrigeration system was developed under frost conditions, using EES. The performance of the refrigeration system was predicted with the indoor and outdoor air temperature, outdoor air velocity, and compressor speed. As a result, the system performance decreased, with the increase of frost growth. When the blocking ratio was 40.4% in the basic condition, the refrigeration capacity was decreased by 27.1%, compared to the non-frost condition.

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

Cooling Performance of a Hybrid Refrigeration System for Telecommunication Equipment (통신기기 냉각용 하이브리드 냉방시스템의 성능특성)

  • Jeon, Jong-Ug;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.489-494
    • /
    • 2006
  • Electronic and telecommunication industries are constantly trying to develop compact components having high power density. Therefore, a proper heat dissipation method is very important to allow reliable operation of the telecommunication equipment. In this study, a hybrid refrigeration system for a telecommunication equipment room was designed to save energy consumption and improve reliability of the compressor In addition, the performance of the hybrid refrigeration system was measured with a variation of outdoor load. The designed hybrid refrigeration system for the telecommunication equipment shelter saved the energy approximately 50%e at the mode switch temperature of $8.3^{\circ}C$.

  • PDF

Performance and heat transfer characteristics of refrigeration system using R-502 alternatives (R-502의 대체냉매를 사용한 냉동시스템의 성능 및 열전달 특성)

  • 박창대;김민수;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.624-632
    • /
    • 1999
  • In order to replace CFC-502 which has been widely used in transportation and low temperature refrigeration system, performance tests using HFC-407A, HFC-404A and HFC-507 have been carried out. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$and $54.5^{\circ}C$ for each refrigerant. System performance characteristics and heat transfer characteristics of each refrigerant were obtained at several compressor speeds and evaporating temperatures ranging from$-25^{\circ}C$ to $-10^{\circ}C$ Test results show that the use of tested alternative refrigerants without changing system components offers the potential performance improvement of a refrigeration system.

  • PDF

Part-Load Performance Test of a Screw Chiller with Economizer using R22 and R407C (이코노마이저를 채용한 스크류 냉동기에서 R22와 R407C의 부분부하 성능실험)

  • 장영수;이용철;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.902-909
    • /
    • 2003
  • Screw compressor type chillers are widely used in refrigeration for capacity over 30 RT. In general, chillers operate under part-load conditions. Therefore, information on characteristics at part-load is very important in view of chiller performance and energy economy. In this study, performance tests of part-load and economizer system using R22 and R407C have been performed for various secondary fluid temperatures. Adoption of an economizer system increased the cooling capacity and improved COP except for lower part-load condition when injection volume ratio is 1.01. For the same cooling capacity condition at part-load, COP of both non-economizer and economizer system showed similar values.

Experimental Study on the Rapid Cooling System by Refrigerant Storage Method (냉매 저장방식에 의한 쾌속 냉각장치에 대한 실험적 연구)

  • 장기태;고준석;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.937-942
    • /
    • 2003
  • In the present study, low-temperature low-pressure refrigerant storage method is proposed to achieve higher cooling capacity during a short period of time than that of a compressor in steady operation. Experimental apparatus was designed and set up to analyze the performance of the new-conceptual cooling system. Two reservoirs for sequential storage of refrigerant were used in the cooling system. Several on/off solenoid valves were installed for control of refrigerant flow. From the experimental results, the initial rapid cooling by low temperature low-pressure refrigerant storage method was ascertained for successful operation. This rapid cooling methodology shall be useful for other low-capacity refrigeration system.

Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system (텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어)

  • Han, Do-Young;Kim, Jae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

A Study on the Energy Storage System Using Air Source Heat Pump for Heating and Cooling (공기 열원을 이용한 축열식 냉난방 시스템 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Seo, Jeong-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1125-1130
    • /
    • 2006
  • An air source heat pump system producing the ice and water storage energy for cooling and heating of building has been proposed. Cycle design and simulation considering energy balance between heating and cooling capacity has been carried out. The roles of the capacity controlled compressor, refrigerant heating device and air preheating are investigated in detail. System control logic for meeting the predetermined heating capacity when the system is operated at cold climate condition is suggested. Some anticipated problems of the proposed system are also described.

  • PDF