• 제목/요약/키워드: Refrigerants

검색결과 375건 처리시간 0.033초

탄화수소계 냉매의 증발 압력강하 특성에 관한 실험적 연구 (Study on Evaporation Pressure Drop of Hydrocarbon Refrigerants)

  • 이광배;이호생;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.533-539
    • /
    • 2005
  • Experimental results are presented for heat transfer and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers. Two tubes with a tube diameter of 12.70mm and 9.52mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7mm and 9.52mm. The results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

이산화탄소/프로판 혼합냉매의 냉방성능 특성 (Cooling Performance of Several $CO_2/propane$ Mixtures in an Air-Conditioning System)

  • 김주혁;김민수
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.47-54
    • /
    • 2006
  • [ $CO_2$ ] and propane mixtures were chosen as promising alternative refrigerants and their performance potentials were evaluated experimentally in an air-conditioning system. Pure $CO_2$ and 85/15, 75/25 and 60/40 binary blends by the charged mass percentage of $CO_2/propane$ were selected as working fluids. The effect of the inlet temperature of the secondary fluids and degree of superheat on the cooling performance was tested and discussed. The charging amounts of refrigerants were adjusted to make the system show the maximum COP. Comparisons among different refrigerants were carried out on the same compressor speed basis for a given operating condition. In addition, the temperature gliding effect of zeotropic mixtures on the system performance were analyzed based on the drop-in test results.

친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측 (Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants)

  • 노건상;김종열
    • 수산해양교육연구
    • /
    • 제25권2호
    • /
    • pp.301-306
    • /
    • 2013
  • In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.

탄화수소계 냉매의 응축 압력강하에 관한 연구 (Study on Condensing Pressure Drop of Hydrocarbon Refrigerants)

  • 김재돌;최준혁;정석권;윤정인;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

Performance of Alternative Refrigerants in Low Temperature Chillers

  • Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.67-79
    • /
    • 1998
  • This paper is about the performance of alternative refrigerants for low temperature and transport refrigeration chillers. A breadboard refrigeration chiller was constructed with counterflow heat exchangers. R502, its transitional alternatives of R402A and R402B, and long-term alternatives of R404A and R507 were tested in an attempt to compare the performance of each refrigerant against R502. Measurements were conducted at two condensing temperatures of 43.3$^{\circ}C$ and 52.$0^{\circ}C$ and the evaporating temperature was varied over a range from -$25^{\circ}C$ to -5$^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about 5$^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this work can be used as 'drop-in fluids' to replace R502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

열전달 촉진관에서 탄화수소계 냉매의 풀비등 열전달계수 (Pool Boiling Heat Transfer Coefficients of Hydrocarbon Refrigerants on Various Enhanced Tubes)

  • 박기정;정동수
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1017-1024
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of five hydrocarbon refrigerants of propylene, propane, isobutane, butane and dimethylether (DME) were measured at the liquid temperature of $7^{\circ}C$ on a 26 fpi low fin tube, Turbo-B, and Thermoexcel-E tubes. All data were taken from 80 to $10kW/m^2$ in the decreasing order of heat flux. The data of hydrocarbon refrigerants showed a typical trend that nucleate boiling HTCs obtained on enhanced tubes also increase with the vapor pressure. Fluids with lower reduced pressure such as DME, isobutane, and butane took more advantage of the heat transfer enhancement mechanism of enhanced tubes than those enhancement ratios of $2.3\sim9.4$ among the tubes tested due to its sub-channels and re-entrant cavities.

고온용 밀폐형 왕복동 압축기에서 탄화수소계 혼합냉매 적용 (The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for high back pressure conditions)

  • 김기문;박희용
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.262-269
    • /
    • 1999
  • The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for dehumidifier is investigated. The selected refrigerants are R12, R134a, HC-Blend (R290/R600a), CX(R152a/R600a) and OS-l2a. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to traditional refrigerant(R12) and R134a. The results show that hydrocarbon refrigerant mixtures(HC-Blend, CX and OS-l2a) are very good alternatives in the refrigeration system for R12 and R134a.

  • PDF

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.

전기식 냉동기에서 냉매의 공급온도에 따른 액화천연가스의 톤당 냉열 가격 산출에 대한 연구 (A Study on the Price Evaluation Per 1 Ton of Liquefied Natural Gas According to the Refrigerants Supply Temperature in the Electric Refrigerator)

  • 김영우;박일수;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.473-477
    • /
    • 2019
  • In this paper, cold heat price contained in the 1 ton/h of LNG has been evaluated using PRO/II with PROVISION release 10.2 from Aveva company when LNG is used to liquefy several refrigerants instead of using vapor recompression refrigeration cycle. Normal butane, R134a, NH3, R22, propane and propylene refrigerants were selected for the modeling of refrigeration cycle. It was concluded that LNG cold heat price was inversely proportional to the refrigerant supply temperature, even though LNG supply flow rate is not varied according to the refrigerant supply temperature.