• 제목/요약/키워드: Refrigerant Property

검색결과 25건 처리시간 0.021초

Characteristic of Quenching Refrigerant for Heat Treatment Deformation Control of SM45C Steel

  • Lyu, Sung-Ki
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.647-654
    • /
    • 2002
  • This study deals with the characteristic of quenching refrigerant for heat treatment deformation control of SM45C steel. Heat-treatment deformation must be controlled for the progress of production parts for landing gear. Most of deformation is occurred on inconsistent cooling. The inconsistent cooling is caused by a property of quenching refrigerant. When a heated metal is deposited in the quenching refrigerant, the cooling speed is so slow in early period of cooling because of a steam-curtain. After additional cooling, the steam-curtain is destroyed. In this progress, the cooling speed is very fast. The object of this study is to control the deformation of heat-treatment for landing gear by improving the conditions of quenching. The cooling curves and cooling rates of water, oil and polymer solution are obtained and illustrated. From the characteristics of the quenching refrigerant, the effects of heat-treatments on thermal deformation and fatigue strength are also investigated.

R12 냉매를 이용한 냉동압축기 임펠러 유동해석 (Numerical analysis on the impeller of chiller compressor using refrigerant R12)

  • 음학진;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

Current State and Future of Refrigerants for Refrigeration and Air Conditioning

  • Kagawa, Noboru
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.182-190
    • /
    • 2007
  • Refrigeration and air-conditioning equipments are indispensable products in this civilized society. However, discharged refrigerants used in the equipments and exhausted carbon dioxide to drive the refrigeration and air-conditioning equipments are related to serious environmental problems and energy problems. Especially, the destroyed ozonosphere by the discharged refrigerants and the increased normal temperature by carbon dioxide and fluorocarbon refrigerants (green house gases) are sounded as serious global problems. For alleviating these problems, environmental-friendly refrigeration and air-conditioning equipments must be developed and will spread soon. To develop new equipment, a suitable refrigerant for each usage must be presented. In this paper, the current state of refrigerants was introduced. And, thermophysical properties of the refrigerants were introduced briefly. From the properties, the refrigerants and refrigeration cycles are promising to be used in the future, were proposed

대체냉매를 적용한 대형 압축식 냉동기의 만액식 증발기에 대한 성능 해석 (Performance Analysis of the Flooded Refrigerant Evaporators for Large Tonnage Compression-Type Refrigerators Using Alternative Refrigerants)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.18-25
    • /
    • 2016
  • 대형 압축식 냉동기의 증발기 전열관으로는 그간 평활관이 주로 사용되어 왔으나 최근들어 비등 성능이 우수한 성형 가공관을 많이 사용하고 있다. 증발기는 관군으로 구성되고 따라서 증발기 내 위치에 따라 냉매 상태가 다르다. 특히 R-11, R-123과 같은 저압 냉매는 압력변화에 따른 포화온도 변화가 크므로 위치에 따라 포화온도가 다르게 된다. 따라서 증발기를 적절히 설계하려면 증발기 내 각 위치에서의 냉매의 상태를 적절히 예측하여야 한다. 본 연구에서는 대형 냉동기의 만액식 증발기를 모사할 수 있는 컴퓨터 프로그램을 개발하였다. 이 프로그램은 증발기를 미소 체적으로 구분하고 각 미소 체적에 적절한 관 내외측 열전달 및 압력손실 상관식을 적용하여 해석을 수행하였다. 본 프로그램을 R-123을 사용하는 T사의 만액식 증발기 해석에 적용한 결과 만족할 만한 결과를 얻었다. 이 프로그램을 이용하여 신 냉매인 R-123, R-134a를 사용하는 만액식 증발기의 해석을 수행하였고 특히 관군 세장비의 영향을 검토하였다.

SCM415강의 열처리 변형제어를 위한 냉각 매질의 특성 (Characteristic of Refrigerant for Heat-treatment Deformation Control of SCM415 Steel)

  • 안민주;류성기
    • 한국기계가공학회지
    • /
    • 제9권6호
    • /
    • pp.59-65
    • /
    • 2010
  • This study deals with the characteristic of refrigerant for heat-treatment deformation control of SCM415 steel. The control of heat-treatment deformation must need the progress of production parts for an industry machine. Most of the deformation is occurred on unequal cooling. The unequal cooling is occurred by a property of quenching refrigeration. When a heated metal is deposited in the refrigeration, the cooling speed is so slow in early period of cooling because of occurring a steam-curtain. After more cooling, the steam-curtain is destroyed. In this progress, the cooling speed is very fast. The object of this study is to control the deformation of heat-treatment for the part of the industry machine by improving the conditions of quenching. The cooling curves and cooling rates of water, oil and polymer solution are obtained and illustrated. From the characteristics of the quenching refrigerant, the effects of heat-treatments on the thermal deformation and fatigue strength are also investigated.

CFC 대체냉매를 사용한 핀-관 열교환기의 성능해석 (The Performance Analysis of the Fin-Tube Heat Exchanger Using CFC Alternative Refrigerant)

  • 박희용;박경우;차재병
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2358-2372
    • /
    • 1993
  • In this study, the computer modeling for prediction of the performance of fin-tube heat exchanger using alternative refrigerant, HFC-134a was developed and the computer program for calculating the various properties of HFC-134a and the existing refrigerant CFC-12 and HCFC-22 was made. The heat exchanger modeling is based on a tube-by-tube approach, which is capable of analysis for the complex coil array. Performance of each tube is analyzed separately by considering the cross-flow heat transfer with external airstream and the appropriate heat and mass transfer relationships. A performance comparison according to the different refrigerants is provided using this developed model. As the result of this study, total heat transfer rate of evaporator and condenser using HFC-134a were found higher than that of using CFC-12 for the same operating conditions. When the mass flow rate of HFC-134a was less than CFC-12 about 18. 16%, the cooling capacities of evaporator were found to be the same.

SM45G강의 열처리변형 제어를 위한 냉각매질의 특성 (Characteristic of Refrigerant for Heat-treatment Deformation Control of SM45C Steel)

  • 류성기;남태현;안민주;박중학
    • 열처리공학회지
    • /
    • 제13권5호
    • /
    • pp.330-336
    • /
    • 2000
  • This study deals with the characteristic of refrigerant for heat-treatment deformation control of SM45C steel. The control of heat-treatment deformation must need the progress of production parts for a landing gear. Most of the deformation is occurred on unequal cooling. The unequal cooling is occurred by a property of quenching refrigeration. When a heated metal is deposited in the refrigeration, the cooling speed is so slow in early period of cooling because of occurring a steam-curtain. After more cooling, the steam-curtain is destroyed. In this progress, the cooling speed is very fast. The object of this study is to control the deformation of heat-treatment for landing gear by improving the conditions of quenching. The cooling curves and cooling rates of water, oil and polymer solution are obtained and illustrated. From the characteristics of the quenching refrigerant, the effects of heat-treatments on thermal deformation and fatigue strength are also investigated.

  • PDF

수정된 Carnahan-Starling 상태방정식을 이용한 혼합냉매의 물성계산 (Estimation of Thermodynamic Properties of Refrigerant Mixtures Using a Modified Carnaha-Starling Equation of State)

  • 김민수;김동섭;노승탁
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2189-2205
    • /
    • 1991
  • 본 연구에서는 혼합냉매의 열역학적 물성치를 정확하게 예측하기 위하여 척력 과 인력항으로 된 간단한 형태의 상태방정식을 택하고 이를 이용하여 순수성분에 대한 열역학적 물성치 자료와 혼합냉매에 대한 기액평형상태 자료를 이용하여 혼합물에 대 한 열역학적 물성치를 보다 더욱 정확하게 예측 할 수 있는 방법에 관해 연구하고자 한다.혼합냉매에 대한 상태방정식과 이상기체 상태의 비열자료를 기초로 열역학적 관계식을 이용하여, 압력-엔탈피, 온도-엔트로피 관계를 공식화하며, 혼합냉매에 대한 열펌프 및 냉동사이클 해석에 필요한 자료를 제시한다.

대체냉매 R-32(Difluoromethane)의 열역학적 물성과 R-22 대체냉매로서 열역학적 성능의 초기 평가 (Thermodynamic Properties of R-32(Difluoromethane) and Initial Evaluation of Thermodynamic Perfomance as A R-22 Alternative Refrigerant)

  • 박영무
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.141-155
    • /
    • 1993
  • Thermodynamic properties of R-32 are calculated and its refrigeration performance is evaluated for the purpose the feasibility study of replacing R-22 with R-32. (1) Refrigeration effect of R-32 is superior to that of R-22 because heat of evaporation of R 32 is about 50% higher than that of R-22. However, COP of R-32 system is 10-30% lower than that of R-22 system. It is mainly attributed to the vapor pressore of R-32 being about 62% higher than R-22. (2) Since the pressure ratio and the specific heat ratio of R-32 system is higher than those of R -22, compressor discharging temperature rises as high as to $130-150^{\circ}C$. It may cause mechanical failure of compressor due to the breakdown of lubricant. Compressor should be improved to lower the temperature if R-32 is to replace R-22. (3) Averaged two-phase heat transfer coefficient of R-32 is about 10-20% higher than that of R-22. It may assume better heat exchanger effectiveness but not guarantee the better COP of R-32 system than R-22. (4) The high vapor pressure is the first reason to drop R-32 out of the line of R-22 alternative refrigerant. So, refrigerant mixtures based on R-32 are recommended to adjust the vapor pressure first and keep superior volumetric capacity of R-32.

  • PDF

신냉매 R1234yf의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R1234yf)

  • 박기정;이철희;강동규;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.345-352
    • /
    • 2010
  • In this study, external condensation heat transfer coefficients(HTCs) of R134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of $39^{\circ}C$ with the wall subcooling of $3{\sim}8^{\circ}C$. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing R134a which is one of the greenhouse gases controlled by Kyoto protocol and is used extensively in mobile air-conditioners. Test results show that the external condensation HTCs of R1234yf are very similar to those of R134a for all three surfaces tested. For the application of condensation heat transfer correlations to the design of condensers charged with R1234yf, thorough property measurements are needed for R1234yf in the near future.