• Title/Summary/Keyword: Refrigerant Compressor

Search Result 352, Processing Time 0.026 seconds

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate (용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chan-Yong;Choi, Jong-Min
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

Numerical analysis on the impeller of chiller compressor using refrigerant R12 (R12 냉매를 이용한 냉동압축기 임펠러 유동해석)

  • Eum, Hark-Jin;Kang, Shin-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

Performance Experiment and Exergy Analysis of an Automotive Air-conditioning System (자동차용 에어컨 성능실험과 액서지 해석)

  • 오상한;윤종갑;원성필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.363-370
    • /
    • 2000
  • Experiments have been peformed, using pure refrigerant R134a and a zeotropic refrigerant mixture R290/R600a(60%/40%) and their performances have been analyzed by the first and second laws(exergy method) of thermodynamics. From the experimental results, variations of compressor speed and air temperature have a great effect on the performance of the system. The sum of exergy losses in compressor and evaporator is about 60% of total exergy loss, using refrigerant R134a, so it is necessary to improve the performance of compressor and evaporator. According to the experimental results using refrigerant mixture of R290/R600a(60%/40%), the exergy losses in heat exchange processes are decreased but the exergy loss in throttling process is increased. The performance of the system has been improved by 20∼30% compared with that of R134a and exergy losses have been also reduced.

  • PDF

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount (냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Yu, Tae-Guen;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

Investigation on Heat Transfer in Scroll Compressor (스크롤 압축기 내부에서의 열전달에 대한 연구)

  • Jang, Ki-Tae;Jeong, Sang-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.199-204
    • /
    • 2003
  • In the present study, the compression process in scroll compressor was simulated in consideration of flow leakage and heat transfer. Tangential and radial leakages of the refrigerant between the scrolls were considered as nozzle flow. The experiment was first conducted with a scroll compressor for automobile air conditioning system and R134a as a refrigerant. Temperature and pressure were measured at the suction and discharge ports of the compressor to determine the thermodynamic states of the refrigerant flow. Temperature distribution of the scroll with the involute angle was also measured by thermocouples that were installed inside the scroll. Measured temperature distribution was compared with the numerical results. From this result, the thermal effect of mechanical contact was found to be important in heat transfer of the compression process.

  • PDF

A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3 I$ (HFC-152a와 HFC-1523에 $CF_3 I$를 혼합한 공비혼합냉매 특성에 관한 연구)

  • 이종인;하옥남;김재열;이연신;권일욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.102-108
    • /
    • 2001
  • To prevent green house effect and destruction of an ozone layer, an ozone destruction potential(OBP) must be zero and a refrigerant for low global warming potential(GWP) is needed. HFC-l34a, in which hydrogen is mixed instead of chlorine is a refrigerant used for automobile conditioners and its destruction potential is ecologically zero. However, it is not consid- ered as a perfect substitutive refrigerant as its GWP is high. It is studied refrigerant mixtures in which HFC-l52a and $CF_3 I$ in HFC-l52a with low GWP and zero ODP are mixed by experimentally and concluded as follows: 1) With the variation of speed of compressor outside temperature and flow rate, 7he heat of evaporator and compressor and coefficient of perfor- mance was varied, and influenced the air conditioner. 2) The pressure of evaporator was decreased with increasing the speed of compressor and the pressure of evaporator with the refrigerant HFC-l52a was higher 24% than that of azotrope refrigerant mixed with $CF_3 I$

  • PDF

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Heat Pump with a Variation of Compressor Speed and Water Flow Rate (압축기 용량 및 유량변화에 따른 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.143.1-143.1
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz, and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWT of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system optimized at higher refrigerant charge amount conditions.

  • PDF

The lubrication Characteristics of a Rotary Compressor used for Refrigeration and Air-conditioning Systems Park II: Analysis of elastohydrodynamic lubrication on vane tip (냉동${\cdot}$공조용 로터리 콤프레서의 윤활 특성 제2보:베인 선단부의 탄성 유체 윤활 특성 해석)

  • Cho, Ihn-Sung;Oh, Seok-Hyung;Jung, Jae-Youn
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.62-69
    • /
    • 1997
  • Rapid increase of refrigeration and air-conditioning systems 9r & a systems) in modern industries brings attention to the urgency of research & development as a core technology in the area. And it is required to the compatibility problem of r & a systems to alternative refrigerant for the protection of environment. The, it is requested to study the lubrication characteristics of refrigerant compressor which is the core technology in the r & a systems. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressor. Therefore, theoretical investigation of the lubrication characteristics of rotary compressor for r & a systems is studied. The newton-Raphson method is used for the EHL analysis between vane and rolling piston in the rotary compressor. The results show that the rotational speed of a shaft and the discharge pressure influence significantly the friction force between vane and rolling piston. This results give important basic data for the further lubrication analysis and design of a rotary compressor.

Friction and Wear of the Scroll Compressor Sliding Surfaces in the Natural Refrigerant $CO_2$ Environment (자연냉매 $CO_2$환경에서 스크롤 압축기 구동부의 마찰 마멸특성 평가)

  • 오세두;문재용;조성욱;이인주;김철우;이영제
    • Tribology and Lubricants
    • /
    • v.19 no.3
    • /
    • pp.146-150
    • /
    • 2003
  • The natural refrigerant $CO_2$has attracted as an alternative refrigerant currently used in air conditioning system, which has high global warming potential. In this study, the tribological characteristics of the sliding surfaces between a fixed scroll and an orbiting scroll of the scroll compressor were investigated in $CO_2$/ POE mixed environment. The pin-on-disk type sliding tests were carried out under the various sliding speeds, normal loads. surface roughness, and pressures. During the test, friction forces, wear amount and surface temperature were monitored.

Numerical Study on the Performance Characteristics of a Centrifugal Compressor for a R134a Turbo-Chiller (R134a 터보냉동기용 원심압축기의 성능특성에 관한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.2 s.23
    • /
    • pp.14-20
    • /
    • 2004
  • In this study, the overall performance and the local flow field of the centrifugal compressor with the refrigerant HFC-l34a were numerically studied using CFX-TASCflow. The thermodynamic and transport properties of the refrigerant gas were modeled by REFPROP which is NIST refrigerant properties database. The impacts of a grid qualify, discretization scheme, turbulent model and interaction between a impeller and a cascade diffuser were analyzed comparatively. The results were compared with experimental data and 1-D design results using COMPAL and agreed well with others. The numerical method and data obtained in this study can be applied to the design and modification of centrifugal compressors with real gases