• Title/Summary/Keyword: Refractory organic

Search Result 95, Processing Time 0.018 seconds

Ethyl Silicate Bonded Alumina as a Ceramic Binder

  • N, Korobova;Dea-Wha, Soh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.103-107
    • /
    • 2002
  • Ethyl silicate was used as organic binder for alumina refractories. In the present work only 15% of the water required for complete hydrolysis of ethyl silicate was initially added. The balance was provided from the atmosphere under controlled conditions of temperature and rh. The purpose of detailing the possible binder problem areas is more to indicate that the binder can have an effect on ceramic operations.

  • PDF

Current Status of Refractory Dissolved Organic Carbon in the Nakdong River Basin (낙동강유역 난분해성 용존 유기탄소 배출 현황 분석)

  • Lee, Jeonghoon;Kim, Jungsun;Lee, Jae Kwan;Kang, Limseok;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.538-550
    • /
    • 2012
  • This study suggests a general methodology which is designed for assessing RDOC behavior at the catchment scale by coupling properly a series of steam flow and water quality simulation models and actual monitoring data set. The modified TANK model in which a river routing function is incorporated to the conventional one is applied to simulate the long-term daily stream flow data, and the simulated stream flow data is combined with the 7-parameter log-linear model coupled to the minimum variance unbiased estimator to simulate the long-term daily water quality (BOD, COD and TOC) loads. Finally, the regression analysis between the usually monitored water quality data (BOD, COD and TOC) and RDOC is combined with the simulated water quality data to manifest the spatio-temporal variability of RDOC flux behavior at the Korean TMDL catchment scale.

Evaluation of Eutrophication and Water Quality in Kumoh Reservoir (금오지의 수환경 및 부영양화 평가)

  • Park, Je Cheol;Kim, Dong Seop;Lee, Seung Hwan
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.389-401
    • /
    • 2004
  • Seasonal and vertical distribution of water quality were investigated from May 2001 to June 2002 in Kumoh reservoir located nearby Kumi City, Kyungpook. Kumoh reservoir that lost the role of agricultural irrigation is currently of rapid eutrophication. The vertical distribution of DO was observed clinograde with hypolimnetic anoxic zone. T-P concentrations at the surface ranged from 0.008 to 0.152 mgP/L and T-N concentrations ranged from 1.4 to 3.0 mgN/L. The vertical and seasonal variation of T-N was smaller than T-P. DOC concentrations, indicator of organic matter pollution, ranged from 2.8 to 5.4 mgC/L. Apportionment of Total-DOC (T-DOC) indicated that 14% of T-DOC was attributed to Labile-DOC(L-DOC) and the rest was due to Refractory-DOC(R-DOC). The values of TSI(Trophic State Index) ranged between 44 and 52 indicating that Kumoh reservoir is under mesotrophic condition. The results of this study indicate that Kumoh reservoir is likely to be under influence of eutrophication and thus water quality will be aggravated. Therefore, the Kumoh reservoir requires further treatment to improve water quality and a plan of the reusing water resource should be developed.

Response of Size-fractionated Phytoplankton to Humic Acids in the Seawater of Yeongsan River Estuary (영산강 하구에서 부식산이 식물플랑크톤에 미치는 영향)

  • Sehee Kim;Yongsik Sin
    • Ocean and Polar Research
    • /
    • v.45 no.3
    • /
    • pp.113-123
    • /
    • 2023
  • Humic substances are refractory organic compounds that are relatively low in biological activity but known to stimulate phytoplankton growth in estuarine and marine environments. The effect of humic substances on phytoplankton growth was investigated in the seawater zone of the Yeongsan River estuary where an episodic anthropogenic freshwater is discharged, affecting its water properties directly. Water samples and data of water properties were collected at three stations (Sts. A-C) along the channel of the seawater zone in February, May, August and November, 2009. The collected water samples were incubated after humic acids (HA) were added in mesocosm experiments. Phytoplankton (chlorophyll-a) were fractionated into net- (> 20 ㎛) and nano-size (< 20 ㎛) to examine the response of phytoplankton according to size. Their response to HA treatment was assessed by repeated measures analysis of variance (RM-ANOVA). The experiments showed that phytoplankton biomass (chlorophyll-a) significantly increased after HA were added at the stations near the sea dike. Especially, nano-sized chlorophyll-a concentrations increased significantly throughout the seasons. This indicates that understanding the behavior of refractory organic matters such as humic substances is required to better manage altered estuarine ecosystems including the Yeongsan River estuary which are affected by episodic discharge of freshwater from sea dikes.

Application of TOC Standards for Managing Refractory Organic Compounds in Industrial Wastewater (난분해성 유기물 관리를 위한 산업폐수 TOC 기준 적용방안 연구)

  • Choi, Ik-Won;Kim, Jae-Hoon;Im, Jong-Kwon;Park, Tae-Jin;Kim, Se-Young;Son, Dae-Hee;Huh, In-Ae;Rhew, Doug-Hee;Yu, Soon-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The aim of this study is to understand the limitation of organic pollutant indexes ($BOD_5$, $COD_{Mn}$, $COD_{Cr}$) and estimate to set the TOC standard by comparing oxidation rates of $BOD_5$, $COD_{Mn}$, $COD_{Cr}$ and TOC based on the 487 organic compounds and 11 effluents from industrial wastewater containing various and unknown organic compounds. The range of ratio of theoretical oxygen demand (ThOD) to theoretical organic carbon (TOCt) was 0.00~5.33 and average ratio of classes of organic compounds was 2.68~3.70. According to classes of organic compounds, the average ratio of $O_2/C$ was 1.2 (range : 1.02~1.39). The order of oxidation rate for 15 organic compounds was TOC (90.7%) > $COD_{Cr}$ (88.8%) > $BOD_5$ (54.4%) > $COD_{Mn}$ (30.8%) indicating the lower oxidation rate of $BOD_5$ and COD compared with TOC. The ranking for average oxidation rate was $COD_{Cr}$ > $COD_{Mn}$ > $BOD_5$ indicating that $BOD_5$, $COD_{Mn}$ could be underestimated comparing with ThOD of organic compounds in case of industrial wastewater containing high concentration of refractory organic compounds. Most of the relationships between organic pollutant indexes and TOC were higher than 0.9. The ratio of TOC to organic compound indexes decreased in the order : $COD_{Cr}$ (3.4) > $COD_{Mn}$ > (1.9) > $BOD_5$ (0.7).

UV-OXIDATIVE TREATMENT OF BIO-REFRACTORY ORGANIC HALOGENS IN LEACHATE: Comparison Between UV/O3, UV/H2O2, and UV/H2O2/O3 Processes

  • Qureshi, Tahir Imran;Kim, Young-Ju
    • Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.84-90
    • /
    • 2006
  • UV-catalytic oxidation technique was applied for the treatment of bio-refractory character of the leachate, which is generally present in the form of adsorbable organic halogens (AOX). Destruction of AOX was likely to be governed by pH adjustment, quantitative measurement of oxidants, and the selection of oxidation model type. Peroxide induced degradation ($UV/H_2O_2$) facilitated the chemical oxidation of organic halides in acidic medium, however, the system showed least AOX removal efficiency than the other two systems. Increased dosage of hydrogen peroxide (from 0.5 time to 1.0 time concentration) even did not contribute to a significant increase in the removal rate of AOX. In ozone induced degradation system ($UV/O_3$), alkaline medium (pH 10) favored the removal of AOX and the removal rate was found 11% higher than the rate at pH 3. Since efficiency of the $UV/O_3$ increases with the increase of pH, therefore, more OH-radicals were available for the destruction of organic halides. UV-light with the combination of both ozone and hydrogen peroxide ($UV/H_2O_2$ 0.5 time/$O_3$ 25 mg/min) showed the highest removal rate of AOX and the removal efficiency was found 26% higher than the removal efficiency of $UV/O_3$. The system $UV/H2O_2/O_3$ got the economic preference over the other two systems since lower dose of hydrogen peroxide and relatively shorter reaction time were found enough to get the highest AOX removal rate.

Utilization of Food Sources Before and After the Tsunami in Nuttallia olivacea at Gamo Lagoon, Japan

  • Shin, Woo-Seok;Nishimura, Osamu
    • Environmental Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.259-265
    • /
    • 2013
  • This study was conducted June 2011 at Gamo Lagoon, after tsunami of March 2011, to estimate food sources and utilization. The results show that the tsunami affected the sediment properties by changing the physical environmental alterations. The fatty acids of the gut content of Nuttallia olivacea mostly comprised the same organic matter found in the sediment. Fatty acids in the tissues showed mainly diatoms, bacteria, and dinoflagellates. That is, most of the food sources (i.e., diatoms, bacteria, dinoflagellates, macroalgae, and terrestrial organic matter) probably pass through the digestive system unharmed; however, terrestrial organic matter, which is refractory to biochemical degradation, indicated a different assimilation trend between the gut content and the tissue. This result suggests that input of labile organic matter from the sediment may control selective metabolism in N. olivacea. From these results, although the physical environment of sediment characteristics by tsunami changed, the food utilization of N. olivacea suggested a better assimilation of selected components from the gut content, irrespective of physical alteration.

A Comparative Study of Catalytic Ozone processes for Removal of Refractory Organics (난분해성 유기물질 제거를 위한 오존/촉매 공정의 비교에 관한 연구)

  • Lee, Gyu-Hwan;Lee, Yu-Mi;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.199-205
    • /
    • 2006
  • Ozone alone and catalytic ozone processes were introduced for treatment of humic acid, which is representative refractory organic compound. The treatment efficiencies of humic acid in each process were analyzed in pH variation, DOC removal, and $UV_{254}$ decrease. Mn loaded GAC catalyst was prepared by loading potassium permanganate onto the granular activated carbon surface. BCM-GAC and BCM-Silica gel catalyst were prepared by BCM. $UV_{254}$ decrease in all processes was comparatively high with efficiency over 87%. DOC removal in ozone/GAC process was the highest with 78%, and removal rates for other processes followed the order ozone/BCM-GAC(62%) > ozone/BCM-silica gel(45%) > ozone/silica gel(43%) > ozone/Mn Loaded GAC(42%) > ozone alone(37%).

  • PDF

PAC Pretreatment for Ultrafiltration of RBC Effluent (PAC-한외여과막을 이용한 회전원판 처리수의 고도처리)

  • Ahn, Kyu-Hong;Song, Kyung-Guen;Park, Joon-Hong;Kweon, Ji-Hyang;Kim, Hyung-Soo;Kwak, Jong-Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.70-79
    • /
    • 1996
  • Ultrafiltration(UF) and powdered activated carbon(PAC) adsorption were combined to treat wastewater contaminated with refractory organic compounds. Secondary sewage effluent of RBC process was used for the investigation. It was determined from batch test results that a contact time of 2 hours and a PAC dose of 450mg/l would be used in the experiments. Backwashing was accomplished by forcing the permeates back ward with pressure of $2.5kgf/m^2$ for 90 seconds. It was shown that refractory organics removal by the PAC-UF process was more efficient than UF process without PAC pretreatments. As backwashing frequency was decreased from four times to one time in an hour, the removal efficiency was significantly increased. The addition of PAC to the UF process mitigated the fluctuation of filtrate quality which was increased in UF process without PAC treatment as transmembrane pressure was increased.

  • PDF