• Title/Summary/Keyword: Reflection site

Search Result 126, Processing Time 0.026 seconds

Site Investigation of Abandoned Coal Mine and Stability of Road Tunnel (도로터널공사구간의 폐갱도 정밀조사 및 터널의 안정성 평가)

  • Shin, Hee-Soon;Kim, Jung-Yul;Lee, Byung-Joo;Han, Kong-Chang;Sunwoo, Choon;Song, Won-Kyung;Synn, Joong-Ho;Kim, Yoo-Sung;Park, Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.17-24
    • /
    • 2001
  • Several underground cavities were found during construction of a road tunnel in 600m length . The area belong to Whasoon coalfield where extensive ground subsidences have occurred. It is necessary to find other underground cavities which might be located just near the road tunnel for safety, The field surveys and laboratory tests were conducted such as surface geological survey(672m), surface reflection seismic exploration(399m), drilling test(3 NX holes), 9 laboratory tests for rocks, 3 boreholes televiewer tests, reflection seismic exploration in tunnel(2, 342m). To estimate the effects of underground cavities on the road tunnel, 3 geological section were analysed with FLAC-2D modeling. The effects of the ground reinforcement were also analysed.

  • PDF

A Study on the Cafe Architecture Reflecting the Characteristics of Jeju (제주지역 특성을 반영한 카페건축에 관한 연구)

  • Kim, Jeongil;Kim, Hyoungjun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.107-112
    • /
    • 2021
  • This study aims to analyze a cafe built by reflecting the characteristics of Jeju among the cafes in Jeju. This is to provide practical help to prospective prep entrepreneurs who want to start a cafe in Jeju. The cafe reflecting the characteristics of Jeju maintains its own competitiveness and constant interest of tourists by securing differentiation and uniqueness. In addition, by looking at the characteristics of Jeju applied to cafe architecture, the academic foundation for understanding the Jeju and applicable characteristics of Jeju were summarized. The study was conducted in parallel with literature analysis and on-site analysis, and as a result, the following contents were found. First, it is a reflection of Jeju's phenomenal materiality. Second, it is a reflection of Jeju's interpretive everyday life. Third, it is a reflection of Jeju's materiality time. In this regard, if prep entrepreneurs start a cafe that reflects the characteristics of Jeju, they can create a cafe with very specific characteristics if they integrate the three characteristics above.

Accuracy Evaluation of Non-prism Total Station for Topographic Surveying (지형측량을 위한 무 프리즘 토털스테이션 정확도 평가)

  • Seo, Dong-Ju
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.5
    • /
    • pp.433-441
    • /
    • 2006
  • With a development of electrical technology in recent, it is possible to measure distance without direct contact to object using laser which launched at instrument and reflect from object. Furthermore, the advent of non prism total station brought the increment of application in many fields including not only road, airport, and harbors but also measurement and monitoring of structural displacement in construction fields. In this study, therefore, to evaluate accuracy of non prism total station, accuracy was analyzed by measuring certain distance which classified by both certain materials and angle of reflection. By this method, the derived values were applied to topographical survey for the efficient applicability. According to a study, result value of non prism total station was satisfBctory regardless of material when the angle of reflection was 90 degrees. RMSE increased when the angle of reflection are gradually increased to acute angle. In result of regression analysis using certain distance which classified by both materials and angles of reflection, there is relationship between distance and angle of reflection, but material has no relevance to the result value. When carrying out general topographical survey, proper application of non prism total station will go far conducting safe and prompt survey at the dangerous site such a road which have lots of traffic flow and rock joint which have high angles of inclination.

Leakage noise detection using a multi-channel sensor module based on acoustic intensity (음향 인텐시티 기반 다채널 센서 모듈을 이용한 배관 누설 소음 탐지)

  • Hyeonbin Ryoo;Jung-Han Woo;Yun-Ho Seo;Sang-Ryul Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.414-421
    • /
    • 2024
  • In this paper, we design and verify a system that can detect piping leakage noise in an environment with significant reverberation and reflection using a multi-channel acoustic sensor module as a technology to prevent major plant accidents caused by leakage. Four-channel microphones arranged in a tetrahedron are designed as a single sensor module to measure three-dimensional sound intensity vectors. In an environment with large effects of reverberation and reflection, the measurement error of each sensor module increases on average, so after placing multiple sensor modules in the field, measurement results showing locations with large errors due to effects such as reflection are excluded. Using the intersection between three-dimensional vectors obtained from several pairs of sensor modules, the coordinates where the sound source is located are estimated, and outliers (e.g., positions estimated to be outside the site, positions estimated to be far from the average position) are detected and excluded among the points. For achieving aforementioned goal, an excluding algorithm by deciding the outliers among the estimated positions was proposed. By visualizing the estimated location coordinates of the leakage sound on the site drawing within 1 second, we construct and verify a system that can detect the location of the leakage sound in real time and enable immediate response. This study is expected to contribute to improving accident response capabilities and ensuring safety in large plants.

Crystallographic analysis of dehydrated fully Tl+-exchanged zeolite Y

  • Lim, Woo Taik;Kwon, Ji Hye;Choi, Sik Young;Kim, Young Hun;Heo, Nam Ho
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.278-286
    • /
    • 2005
  • The crystal structure of ($Tl_{71}$-Y ($Tl_{71}Si_{121}Al_{71}O_{384}$), ${\alpha}=24.706(3){\AA}$, dehydrated at 653 K and $8{\times}10^{-6}$ torr, has been determined by single-crystal X-ray diffraction techniques in the cubic space group $Fd\bar{3}m$ at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 302 reflection for which $F_{\circ}$ > $4{\sigma}(F_0)$) $R_1=0.0602$ (based on F) and $R_w=0.1744$ (based on $F_2$). The 71 $Tl^+$ ions per unit cell are found at four crystallographically distinct positions. Site I' position in the sodalite cavity opposite D6Rs are each occupied by eighteen $Tl^+$ ions per unit cell; these $Tl^+$ ions are recessed ca. $1.45{\AA}$ into the sodalite cavity from their O(3) plane (Tl-O=2.701(15), $3.163(16){\AA}$ and O-Tl-O=$92.1(4)^{\circ}$). The 23 $T1^+$ ions fill site II in the supercage; these $T1^+$ ions are recessed ca. $1.58{\AA}$ into the supercage from their O(2) plane (Tl-O = 2.850(16), $3.156(16){\AA}$ and O-T1-O = $85.1(5)^{\circ}$). The 19 $Tl^+$ ions lie at site III' in the supercage near a triple 4-ring (Tl-O = 3.10(7), $3.39(5){\AA}$ and O-Tl-O = 47.8(9), $95.3(18)^{\circ}$) and the remaining II ions occupy another site III' near a triple 4-ring in the supercage (Tl-O = 2.81(4), $2.71(4){\AA}$ and O-Tl-O = $57.3(8)^{\circ}$).

A Study on the Architectural Characteristics of Museum design Works of Moshe Safdie (모세 사프디의 미술관 작품에 나타나는 건축 특성에 관한 연구)

  • Ahn, Abraham Chiwon;Kim, Jin-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.5
    • /
    • pp.16-24
    • /
    • 2017
  • This study examines Safdie's design philosophy: place, purpose, and process and design strategies found in museum buildings. Safdie, influenced by personal background as immigrant, education of McGil University in Canada, apprenticeship from Louis Kahn, is one of the most recognized architects who designed renowned public and cultural buildings after Habitat 67 in Montreal, Canada. In order to reveal design strategies his eight museum buildings has been selected and analyzed in terms of interpretation of context, program presented in floor plan and section design, and the process of integrity found in structure and material. The results of this paper can be summarized as follows: 1) Reflection of existing context and regeneration of the locality has been in a creative way to reinforce the sense of place. 2) The layout of major and gallery space is determined according to the Safdie's interpretation of the site context and this can be categorized into three types. 3) Integration of the innovative structural frame and material has been experimented by using tartan grid and toroid form in the major and gallery spaces. This study is intended to reevaluate the significance of Safdie's design approach to building uniqueness of the site, program and tectonic.

A Pilot Study on the Development of an Augmented Reality-based Decision Support System for Free-Form Buildings Construction Management (증강현실 기반의 비정형 건축물 건설관리 의사결정지원시스템 개발에 관한 기초적 연구)

  • Lim, Jang-Sik;Ock, Jong-Ho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.175-187
    • /
    • 2012
  • The BIM simulation systems involve inefficient aspects in delivering real world circumstances because they are operated in the virtual reality (VR) environment without representing the job-site operations. Differently from VR, augmented reality (AR) enhances the reflection of job-site reality to virtual environment. AR influences architecture, design and construction. This reality replaces or merges with the normal physical world and it can be tailored to enhance comprehension for specific design and construction activities. The main objective of this research is to develop an AR-based decision support system for free-form buildings design/construction/maintenance processes. Haewoojae, a free-form housing building built in Seoul area is identified as a model building to generate the system. Seventeen engineers, who are masters or doctorate graduate students at the S university in Seoul and have been working in the Korean construction industry for more than 10 years are invited to validate the system's appropriateness and usability in comparison with its development objectives.

On-Land Seismic Survey of Korea (한국의 육상 탄성파탐사)

  • Kwon, Byung-Doo
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.441-450
    • /
    • 2006
  • The on-land seismic survey in Korea was begun in mid-1960s. Kim et al.(1967) of Korea Geological Survey reported on the result of gravity and seismic reflection surveys conducted in the Pohang area for the period of 1963-64 to assess its possibility of oil entrapment. Hyun and Kim (1966) carried out a refraction survey on the tunnel wall. Since then, the KGS geophysicists had conducted seismic surveys on Kyungsang sedimentary basin as a main project for several years. In 1970s, on-land seismic surveys had been conducted for various purposes such as site investigation for the nuclear power plants and industrial complex, exploration for ground water, mineral resources and underground tunnel. The first reflection survey with CMP acquisition was attempted in 1978 by using a digital recording system. But most of on-land seismic surveys had employed the refraction method until 1980s. In 1990s, high resolution reflection and various borehole seismic surveys such as tomography, uphole, downhole, cross-hole methods have been attempted by universities and engineering companies. The applications of on-land seismic surveys have been enlarged for both academic and industrial purposes such as investigation of geologic structure of the fault and tidal flat area, construction of highway, railroad and dam, geothermal energy and mineral resource exploration, environmental assessment for waste disposal sites and archaeological investigations. In 2002, the first crustal seismic survey was carried out on the profile of 294km length across the whole peninsular. It is expected that the advanced technology and experience acquired through offshore seismic surveys, which have been conducted in continental shelf of Korea and foreign oil fields, will stimulate the more active on-land seismic explorations.

A Study on Suitability of Road Traffic Noise Map for Environmental Noise Impact Assessment (환경소음 영향평가 시 도로교통 소음지도의 적용성 검토 연구)

  • Kim, Ji-Yoon;Park, Sang-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.311-316
    • /
    • 2008
  • It is needed to assess the impact of the road traffic noise for city planning. In Korea, the current noise impact assessment h3s not yet considered the impacts of the multiple reflection, the deflection and the ground attenuation caused by buildings and other obstacles. A noise map is useful tool to solve this problems. But before everything else, suitability of noise map must be assessed for variety of geometry conditions. In this study, we assessed suitability of road traffic noise map by compared measured noise levels with predicted noise levels from each road traffic noise map for Site A, B and C.

  • PDF

A Development of Portable Early Detector of Intravenous Infiltration based on Optical Sensor (광센서 기반 휴대형 침윤 조기 감지기 개발)

  • Lee, Sungjin;Shin, Bum Joo;Jeong, IhnSook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.705-711
    • /
    • 2018
  • Intravenous(IV) therapy being in use for many patients may cause serious side effects such as infiltration, extravasation. To minimize such side effects, it is important to detect symptoms appearing when fluid escapes from blood vessel to tissue as soon as possible. This paper describes a device which has been developed to detect IV infiltration early using optical sensor. The device detects IV infiltration as measuring intensity of lights reflected from that lights after emitting lights in IV therapy site. The lights are consisted of 4 different waves which provide different reflection ratio depending the fluid used in IV therapy. The experimental results show that the device can be used to detect IV infiltration early.