• 제목/요약/키워드: Reflection Rate

검색결과 306건 처리시간 0.023초

비지도학습 데이터의 정확성 측정을 위한 클러스터별 분류 평가 예측 모델에 대한 연구 (A Study on Classification Evaluation Prediction Model by Cluster for Accuracy Measurement of Unsupervised Learning Data)

  • 정세훈;김종찬;김치용;유강수;심춘보
    • 한국멀티미디어학회논문지
    • /
    • 제21권7호
    • /
    • pp.779-786
    • /
    • 2018
  • In this paper, we are applied a nerve network to allow for the reflection of data learning methods in their overall forms by using cluster data rather than data learning by the stages and then selected a nerve network model and analyzed its variables through learning by the cluster. The CkLR algorithm was proposed to analyze the reaction variables of clustering outcomes through an approach to the initialization of K-means clustering and build a model to assess the prediction rate of clustering and the accuracy rate of prediction in case of new data inputs. The performance evaluation results show that the accuracy rate of test data by the class was over 92%, which was the mean accuracy rate of the entire test data, thus confirming the advantages of a specialized structure found in the proposed learning nerve network by the class.

Si(100) 기판상에 성장된 3C-SiC의 특성 (Characterization of 3C-SiC grown on Si(100) water)

  • 나경일;정연식;류지구;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.533-536
    • /
    • 2001
  • Single crystal cubic silicon carbide(3C-SiC) thin film were deposited on Si(100) substrate up to a thickness of $4.3{\mu}m$ by APCVD(atmospheric pressure chemical vapor deposition) method using hexamethyildisilane(HMDS) at $1350^{\circ}C$. The HMDS flow rate was 0.5 sccm and the carrier gas flow rate was 2.5 slm. The HMDS flow rate was important to get a mirror-like. The growth rate of the 3C-SiC films was $4.3{\mu}m/hr$. The 3C-SiC epitaxical layers on Si(100) were characterized by XRD(X-ray diffraction), raman scattering and RHEED(reflection high-energy electron diffraction), respectively. The 3C-SiC distinct phonons of TO(transverse optical) near $796cm^{-1}$ and LO(longitudinal optical) near $974{\pm}1cm^{-1}$ were recorded by raman scattering measurement. The deposition films were identified as the single crystal 3C-SiC phase by XRD spectra($2{\theta}=41.5^{\circ}$). Also, with increase of films thickness, RHEED patterns gradually changed from a spot pattern to a streak pattern.

  • PDF

Heteroepitaxial Growth of Single 3C-SiC Thin Films on Si (100) Substrates Using a Single-Source Precursor of Hexamethyldisilane by APCVD

  • Chung, Gwiy-Sang;Kim, Kang-San
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.533-537
    • /
    • 2007
  • This paper describes the heteroepitaxial growth of single-crystalline 3C-SiC (cubic silicon carbide) thin films on Si (100) wafers by atmospheric pressure chemical vapor deposition (APCVD) at 1350 oC for micro/nanoelectromechanical system (M/NEMS) applications, in which hexamethyldisilane (HMDS, Si2(CH3)6) was used as a safe organosilane single-source precursor. The HMDS flow rate was 0.5 sccm and the H2 carrier gas flow rate was 2.5 slm. The HMDS flow rate was important in obtaing a mirror-like crystalline surface. The growth rate of the 3C-SiC film in this work was 4.3 μm/h. A 3C-SiC epitaxial film grown on the Si (100) substrate was characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), reflection high energy electron diffraction (RHEED), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and Raman scattering, respectively. These results show that the main chemical components of the grown film were single-crystalline 3C-SiC layers. The 3C-SiC film had a very good crystal quality without twins, defects or dislocations, and a very low residual stress.

Si(100) 기판상에 성장된 3C-SiC의 특성 (Characterization of 3C-SiC grown on Si(100) wafer)

  • 나경일;정연식;류지구;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.533-536
    • /
    • 2001
  • Single crystal cubic silicon carbide(3C-SiC) thin film were deposited on Si(100) substrate up to a thickness of 4.3 $\mu\textrm{m}$ by APCVD(atmospheric pressure chemical vapor deposition) method using hexamethyildisilane(HMDS) at 1350$^{\circ}C$. The HMDS flow rate was 0.5 sccm and the carrier gas flow rate was 2.5 slm. The HMDS flow rate was important to get a mirror-like. The growth rate of the 3C-SiC films was 4.3 $\mu\textrm{m}$/hr. The 3C-SiC epitaxical layers on Si(100) were characterized by XRD(X-ray diffraction), raman scattering and RHEED(reflection high-energy electron diffraction), respectively The 3C-SiC distinct phonons of TO(transverse optical) near 796 cm$\^$-1/ and LO(longitudinal optical) near 974${\pm}$1 cm$\^$-1/ were recorded by raman scattering measurement. The deposition films were identified as the single crystal 3C-SiC phase by XRD spectra(2$\theta$=41.5$^{\circ}$). Also, with increase of films thickness, RHEED patterns gradually changed from a spot pattern to a streak pattern

  • PDF

광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상 (Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact)

  • 허영정;윤길원
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

Biodegradation Capacity Utilization as a New Index for Evaluating Biodegradation Rate of Methane

  • Kim, Tae Gwan;Yi, Taewoo;Yun, Jeonghee;Ryu, Hee Wook;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권5호
    • /
    • pp.715-718
    • /
    • 2013
  • Density of catalytic organisms can determine the biodegradation capacity and specific biodegradation rate (SBR). A new index, biodegradation capacity utilization (BCU, %), was developed for estimating the extent of actual biodegradation of a gas compound over the full capacity. Three methanotrophic cultures were serially diluted (1-1/25), and methane SBR and BCU were measured. Consistently, biomass reduction increased the SBR and decreased the BCU. Linearity (p < 0.05, r > 0.97) between the BCU and cell density indicated the reflection of biodegradation capacity by BCU. Therefore, BCU is indicative of whether the density of catalytic organisms is pertinent for SBR evaluation of low-soluble gaseous compounds.

Analysis of Electroencephalogram and Electrocardiogram at an Acupoint PC9 during Pulsed Magnetic Field Stimulus

  • Lee, Jin-Yong;Hwang, Do-Gwen;Yoo, Jun-Sang;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.133-137
    • /
    • 2012
  • We investigated the effects of pulsed magnetic fields (PMF) stimulus on electroencephalogram (EEG) alpha activity and heart rate variability (HRV) from electrocardiogram (ECG) measurements with various stimulus durations at acupoint PC9. The alpha activity in the EEG and the ratio of low frequency power and high frequency power (LHR) in the HRV, a reflection of sympathovagal activity, were increased and decreased, respectively, after PMF stimulus of 3 min. Our spectral analysis quantitatively proved that the changes in the EEG alpha activity were consistent with an autonomic function in the ECG. These findings suggest that appropriate PMF stimulus results in the same effect as that of acupuncture applied to the acupoint PC9, which is closely related to the parasympathetic activity of the autonomic nervous system.

송전계통의 신뢰도 비용 배분 방만에 대한 연구 (An Approach to Allocating Transmission System Reliability Cost)

  • 정구형;신영균;김발호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권4호
    • /
    • pp.183-187
    • /
    • 2002
  • The efficient and rational transmission tariff structure is one of the crucial factors in creation of fair and competitive electricity markets. Transmission charge can be largely categorized into the line usage charge, system reliability charge, access charge and others. Any transmission tariff should be able to reflect these cost components reasonably. This paper suggests an approach amenable to allocating the transmission reliability costs reasonably with reflection of line sensitivity and line outage rate.

저 비트율 전력선 모뎀에 대한 저압 댁내망의 채널 특성 시뮬레이션 기법에 관한 연구 (A Simulation Technique for the Characterization of the Low-bit-rate Household AC Power Line Communication Channel)

  • 안남호;정태규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, the characteristics of the household AC power line network is analyzed for the low bit rate powerline communication (PLC) in the frequency range from 10㎑ to 450㎑ The PLC channel transfer characteristics including its characteristic impedance are derived based on the network topology which is constructed with the household power lines loaded with the various types of electric apparatus. Both the distributed circuit analysis and the lumped circuit model based analysis are applied for the characterization of the PLC channel and the results are compared by the computer simulations. The analysis illustrates very well the adverse effects caused by the loading of electric apparatus and as well those casued by the reflection of wavers in the household AC Power line communication network.

비접촉 얇은 투명체의 두께 측정에 관한 기초연구 (The Study of Non-contact Thickness Measurement of Thin Transparent Object)

  • 홍준희;정석규
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.62-68
    • /
    • 2009
  • In this paper, we investigate a new method to measure the thickness of thin transparent objects utilizing a step index multi-mode optical fiber sensor. The method mainly depends on the refraction rate of transparent target, the diameter of optical fibers and the distance to reflector. We confirmed the effects of these parameters through the experimental verification tests. The comparison between the theoretical vs. analytical results shows good agreements with each other. The proposed model also enables users to measure the thickness of thin transparent objects without considering the reflection from the target. This approach provides simple, cost-effective and non-contact solutions to measure the thickness.