• 제목/요약/키워드: Reference-pulse Type

검색결과 32건 처리시간 0.025초

손목형 생체신호수집 장치에 대한 연구 (A Study on Wrist Band Type Vital Sign Acquisition Device)

  • 김희훈;김경호
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

동기식 스트림 암호 통신에 적합한 사이클 슬립 보상 알고리즘 (A compensation algorithm of cycle slip for synchronous stream cipher)

  • 윤장홍;강건우;황찬식
    • 한국통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1765-1773
    • /
    • 1997
  • PLL을 사용하는 통신 시스템에서는 선로 잡음에 의해서 사이클 슬립 현상이 발생 할 수 있다. 이 사이클 슬립 현상이 동기식 스트림 암호 통신 시스템에 발생하면 난수 동기 이탈 현상을 발생시켜 통신을 할 수 없게 된다. 이러한 난수 동기 이탈의 위험성을 줄이기 위하여 연속 재동기 방식을 사용하지만 이에 따른 문제점이 있다. 본 논문에서는 수신 클럭 복원시에 사용되는 수신 클럭 보상 알고리즘을 연속 재동기 방식에 적용하여 기존의 연속 재동기 방식의 문제점을 해결하는 방법을 제안하였다. 즉, 정해진 기준 시간 동안에 실제 수신 클럭 펄스 수를 계수하여 얻은 계수치와 동일 시간 동안에 사이클 슬립이 발생하지 않은 정상 상태에서의 수신 클럭 펄스 수인 정상치가 일치하지 않으면 사이클 슬럽이 발생된 것으로 판단하여 훼손된 수신 클럭을 사이클 스립의 발생 형태에 따라 클럭 펄스를 더해주거나 빼주는 방법을 연속 재동기 방식과 같이 사용하였다. 제안된 방법을 절대 클럭 동기를 요구하는 동기식 스트림 암호 통신 시스템에서 시험한 결과 기존의 연속 재동기 방법에 비하여 재동기 시간을 최대 20배까지 단축시켰는데 그것은 전송 데이터 량을 17.8% 감축하는 효과와 동일하다.

  • PDF

UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (PD measuring on MV XLPE Calble by Using UWB Antenna)

  • 양상현;임광진;이용성;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

UWB 센서 설계를 통한 고압회전기의 부분방전 진단 연구 (PD Diagnosis On High Voltage Rotating Machines using UWB Sensor)

  • ;임광진;신동훈;김희동;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.197-198
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic pulse emitted from the partial discharge source in the stator winding of HV Rotating Machine with UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on micro-strip technology and made experiments of offline dismantled testing compare with the traditional HFCT as a reference sensor in the laboratory. We investigated internal discharge, surface discharge, corona discharge and non-defected state normal stator on pre-made stator winding by using UWB patch sensor.

  • PDF

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

Prediction of mechanical properties of limestone concrete after high temperature exposure with artificial neural networks

  • Blumauer, Urska;Hozjan, Tomaz;Trtnik, Gregor
    • Advances in concrete construction
    • /
    • 제10권3호
    • /
    • pp.247-256
    • /
    • 2020
  • In this paper the possibility of using different regression models to predict the mechanical properties of limestone concrete after exposure to high temperatures, based on the results of non-destructive techniques, that could be easily used in-situ, is discussed. Extensive experimental work was carried out on limestone concrete mixtures, that differed in the water to cement (w/c) ratio, the type of cement and the quantity of superplasticizer added. After standard curing, the specimens were exposed to various high temperature levels, i.e., 200℃, 400℃, 600℃ or 800℃. Before heating, the reference mechanical properties of the concrete were determined at ambient temperature. After the heating process, the specimens were cooled naturally to ambient temperature and tested using non-destructive techniques. Among the mechanical properties of the specimens after heating, known also as the residual mechanical properties, the residual modulus of elasticity, compressive and flexural strengths were determined. The results show that residual modulus of elasticity, compressive and flexural strengths can be reliably predicted using an artificial neural network approach based on ultrasonic pulse velocity, residual surface strength, some mixture parameters and maximal temperature reached in concrete during heating.

ICP-AES에서 에어로졸의 광산란에 의한 신호의 보정 (Signal compensation by the light scattering of sample aerosols in ICP-AES)

  • 연평흠;박용남
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.223-229
    • /
    • 2012
  • 시료 에어로졸에 의한 광산란 신호를 이용하여 ICP 분석신호를 보정하였다. 자체 제작한 초음파 분무기에서 발생되는 에어로졸에 대하여 다이오드나 He-Ne 레이저를 사용하여 광산란신호를 얻고 이를 기준으로 하여 분석신호의 변동에 대하여 보정하였다. 그 결과 Be, Pb 및 Co의 경우에 short-term (1분 이하)에 대한 신호의 RSD가 기존의 평균 3.4% 에서 0.9% RSD 이하로 큰 개선이 되었으며, 10분 정도의 long-term안정도는 14.9%에서 4.2%로 개선되었다. 이 방법은 펄스형태의 시료도입뿐 아니라 연속적 분무에서도 분무기의 안정성이 부족한 경우, 정밀도의 개선에 매우 유용하다. Long-term의 안정도 개선을 위해서는 광산란셀에서의 안정도 및 검출기의 잡음개선과 분무장치와 플라즈마 사이에서의 에어로졸 응축등에 의한 잡음의 개선이 필요한 것으로 보인다.

OLED Display Module용 DC-DC 변환기 설계 (A DC-DC Converter Design for OLED Display Module)

  • 이태영;박정훈;김정훈;김태훈;카오투안부;김정호;반형진;양권;김형곤;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.517-526
    • /
    • 2008
  • 본 논문에서는 자동차 계기판의 OLED 디스플레이 모듈용 One-chip DC-DC 변환기 회로를 제안하였다. 전하 펌핑 방식의 OLED 패널 구동전압 회로는 PWM(Pulse Width Modulation) 방식을 사용한 DC-DC 변환기 회로에 비해 소형화, 저가격 및 낮은 EMI 특성을 갖는다. 그리고 Bulk-potential 바이어싱 회로를 사용하므로 전하 펌핑 시 기생하는 PNP BJT에 의한 전하 손실을 방지하도록 하였고, 밴드갭 기준전압 발생기의 Start-up 회로에서 전류소모를 기존 BGR 회로에 비해 42% 줄였고 VDD의 링 발진기 회로에 로직전원인 VLP를 사용하여 링 발진기기 레이아웃 면적을 줄였다. 또한 OLED 구동전압인 VDD의 구동 전류는 OLED 패널에서 요구하는 40mA 이상이다. $0.25{\mu}m$ High-voltage 공정을 이용하여 테스트 칩을 제작 중에 있으며, 레이아웃 면적은$477{\mu}m{\times}653{\mu}m$이다.