• Title/Summary/Keyword: Reference temperature

Search Result 1,266, Processing Time 0.119 seconds

Petrology and Geochemical Characteristics of A-type Granite with Particular Reference to the Namsan Granite, Kyeongju (경주 남산일대의 A-형 화강암의 암석학 및 지화학적 특성)

  • 고정선;윤성효;이상원
    • The Journal of the Petrological Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.142-160
    • /
    • 1996
  • Petrological and geochemical characteristics of A-type granite were studied from the Namsan and Tohamsan granites in the vicinity of Kyeongju city, southeastern Korea. The Namsan granite consists of hypersolvus alkali-feldspar granite in the northern part and subsolvus alkali-feldspar to biotite granite in the southern part. This hypersolvus granite usually has miarolitic cavities and is characteristically composed of quartz, single homogeneous one-feldspar (alkali feldspar) forming tabular microperthite crystals, or micrographic intergrowth with quartz, and interstitial biotite (Fe-rich annite), alkali amphibole (riebeckitic arfvedsonite) and fluorite. Petrographic and petrochemical characteristics indicate that the hypersolvus granite and subsolvus granite from the Namsan belogn to the A-type and I-type granitoid, respectively. The A-type granite is petrochemically distinguished from the I-type Bulgugsa granites of Late Cretaceous in South Korea, by higher abundance of $SiO_2$, $Na_2O$, $Na_2O+K_2O$, large highly charged cations such as Rb, Nb, Y, Zr, Ga, Th, Ce. U the REEs and Ga/Al ratio, and lower abundance of $TiO_2$, $Al_2O_3$, CaO, $P_2O_5$, MnO, MgO, Ba, Sr, Eu. The total abundance of REEs is 293 ppm to 466 ppm, showing extensively fractionated granitic compositon, and REEs/chondrite normalized pattern shows flat form with strong Eu '-' anomaly ($Eu/Eu^{\ast}$=0.03-0.05). A-type granite from the Namsan area is thought to have been generated late in the magmatic/orogenic cycle after the production of I-type granite and by direct, high-temperature partial melting of melt-depleted, relatively dry tonalitic/granulitic lower crustal material with underplating by mantle-derived basaltic magmas associated with subduction.

  • PDF

Studies on Thermophilic Flat-sour Bacteria in Soymilk: Isolation, Indentification and Determination of Heat Resistance (두유내의 고온성 Flat-sour 변질균의 분리.동정 및 열저항성에 관한 연구)

  • Chung, Je-Bong;Lee, Kyun-Hee;Sohn, Heon-Soo;Kim, Suk-Min
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.218-224
    • /
    • 1988
  • For the optimization of thermal processing conditions in soymilk process, 4 strains of thermoresistant flat-sour bacteria were isolated from soymilk. The isolates were aerobic spore-forming rods, and grew at $-65^{\circ}C$. Based on the morphological and physiological properties, all of the isolated strains were identified as Bacillus stearothermophilus. The heat resistance of spores of 3 isolates and Bacillus stearothermophillus ATCC 12980 as a reference was determined in soymilk(pH 7.0) and pH 7.0 buffer solution. For each of the spores studied, linear regression equations with standard error were presented for the thermal destruction at 110, 115, 121, and $125^{\circ}C$. It was not obvious that the components of soy milk increased the heat resistance of spores. Between the strains studied, variability was noted in the D values at the different temperature, and no one strain was consistently the most heat resistant at all the given temperatures. The average D value for the 4 strains was 77.27, 20.20, 2.76 and 1.39 min at 110, 115, 121 and $125^{\circ}C$, respectively, and the average z value was $8.36^{\circ}C$.

  • PDF

Dechlorination/Solidification of LiCl Waste by Using a Synthetic Inorganic Composite with Different Compositions (합성무기복합체 조성변화에 따른 모의 LiCl 염폐기물의 탈염소화/고형화)

  • Kim, Na-Young;Cho, In Hak;Park, Hwan-Seo;Ahn, Do-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.211-221
    • /
    • 2016
  • Waste salt generated from a pyro-processing for the recovery of uranium and transuranic elements has high volatility at vitrification temperature and low compatibility in conventional waste glasses. For this reason, KAERI (Korea Atomic Energy Research Institute) suggested a new method to de-chlorinate waste salt by using an inorganic composite named SAP ($SiO_2-Al_2O_3-P_2O_5$). In this study, the de-chlorination behavior of waste salt and the microstructure of consolidated form were examined by adding $B_2O_3$ and $Fe_2O_3$ to the original SAP composition. De-chlorination behavior of metal chloride waste was slightly changed with given compositions, compared with that of original SAP. In the consolidated forms, the phase separation between Si-rich phase and P-rich phase decreases with the amount of $Al_2O_3$ or $B_2O_3$ as a connecting agent between Si and P-rich phase. The results of PCT (Product Consistency Test) indicated that the leach-resistance of consolidated forms out of reference composition was lowered, even though the leach-resistance was higher than that of EA (Environmental Assessment) glass. From these results, it could be inferred that the change in the content of Al or B in U-SAP affected the microstructure and leach-resistance of consolidated form. Further studies related with correlation between composition and characteristics of wasteform are required for a better understanding.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

Different crystalline properties of undoped-GaN depending on the facet of patterns fabricated on a sapphire substrate

  • Lee, Kwang-Jae;Kim, Hyun-June;Park, Dong-Woo;Jo, Byoung-Gu;Kim, Jae-Su;Kim, Jin-Soo;Lee, Jin-Hong;Noh, Young-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.173-173
    • /
    • 2010
  • Recently, a patterned sapphire substrate (PSS) has been intensively used as one of the effective ways to reduce the dislocation density for the III-nitride epitaxial layers aiming for the application of high-performance, especially high-brightness, light-emitting diodes (LEDs). In this paper, we analyze the growth kinetics of the atoms and crystalline quality for the undopped-GaN depending on the facets of the pattern fabricated on a sapphire substrate. The effects of the PSS on the device characteristics of InGaN/GaN LEDs were also investigated. Several GaN samples were grown on the PSS under the different growth conditions. And the undoped-GaN layer was grown on a planar sapphire substrate as a reference. For the (002) plane of the undoped-GaN layer, as an example, the line-width broadening of the x-ray diffraction (XRD) spectrum on a planar sapphire substrate is 216.0 arcsec which is significantly narrower than that of 277.2 arcsec for the PSS. However, the line-width broadening for the (102) plane on the planar sapphire substrate (363.6 arcsec) is larger than that for the PSS (309.6 arcsec). Even though the growth parameters such as growth temperature, growth time, and pressure were systematically changed, this kind of trend in the line-width broadening of XRD spectrum was similar. The emission wavelength of the undoped-GaN layer on the PSS was red-shifted by 5.7 nm from that of the conventional LEDs (364.1 nm) under the same growth conditions. In addition, the intensity for the GaN layer on the PSS was three times larger than that of the planar case. The spatial variation in the emission wavelength of the undoped-GaN layer on the PSS was statistically ${\pm}0.5\;nm$ obtained from the photoluminescence mapping results throughout the whole wafer. These results will be discussed in terms of the mixed dislocation depending on the facets and the period of the patterns.

  • PDF

Regional Frequency Analysis for Rainfall Under Climate Change (기후변화를 고려한 일강우량의 지역빈도해석)

  • Song, Chang Woo;Kim, Yon Soo;Kang, Na Rae;Lee, Dong Ryul;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.125-137
    • /
    • 2013
  • Global warming and climate change have influence on abnormal weather pattern and the rainstorm has a localized and intensive tendency in Korea. IPCC(2007) also reported the rainstorm and typhoon will be more and more stronger due to temperature increase during the 21st century. Flood Estimation Handbook(Institute of Hydrology, 1999) published in United Kingdom, in the case that the data period is shorter than return period, recommends the regional frequency analysis rather than point frequency analysis. This study uses Regional Climate Model(RCM) of Korea Meteorological Administration(KMA) for obtaining the rainfall and for performing the regional frequency analysis. We used the rainfall data from 58 stations managed by KMA and used L-moment algorithm suggested by Hosking and wallis(1993) for the regional frequency analysis considering the climate change. As the results, in most stations, the rainfall amounts in frequencies have an increasing tendency except for some stations. According to the A1B scenario, design rainfall is increased by 7~10% compared with the reference period(1970-2010).

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Development of X-ray Detector using Liquid Crystal with Front Light (전면광원(Front Light)을 적용한 액정 X선 검출기 개발)

  • Rho, Bong Gyu;Baek, Sam Hak;Kang, Seok Jun;Lee, Jong Mo;Bae, Byung Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.831-840
    • /
    • 2019
  • The X-ray detector by liquid crystal with front light was proposed and verified by a X-ray image. The proposed detector utilizes the visible light instead of the electric signal by transistor. Therefore, it shows low noise and can be fabricated at low cost. The liquid crystal detector uses the orientation change of the liquid crystal molecule by conductivity change of the photoconductive layer. We can get the X-ray image from the transmitted light through the liquid crystal. The X-ray dose was calibrated from the measured transmittance of the visible light after comparison to the reference transmittance curve of the liquid crystal. The amorphous Se was used for photo con ducting layer and parylene was used for the liquid crystal alignment instead of the conventional alignment layer which needs high-temperature process over 200℃. The proposed X-ray detector can decrease the X-ray dose by high sensitivity which was verified by simulation. After the fabrication of the X-ray detector, the X-ray image was obtained as a function of the bias voltage to the liquid crystal. 10 lines/mm resolution was obtained from the line pattern and we will apply it to the 17inch diagonal liquid crystal X-ray detector with 3π retardation.

An Analytical Study on Encased Steel Composite Columns Fire Resistance According to Axial Force Ratio (화재시 축력비에 따른 매입형 합성기둥의 내화성능에 대한 해석적 연구)

  • Kim, Ye-Som;Choi, Byong-Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.97-107
    • /
    • 2020
  • In this study, finite element analysis was carried out through the finite element analysis program (ANSYS) to investigate the fire resistance of composite columns in fire. Transient heat transfer analysis and static structural analysis were performed according to ASTM E 119 heating curve and axial force ratio 0.7, 0.6, 0.5 by applying stress-strain curves according to temperature, and loading heating experiments were carried out under the same conditions. In addition, the nominal compressive strength of the composite column according to the heating time according to the standard(Eurocode 4) was calculated and expressed as the axial force ratio and compared with the analytical and experimental values. Through the analysis, As a result of finite element analysis, the fire resistance time was 180 minutes and similar value to the experimental value was obtained, whereas the fire resistance time 150 minutes and 60 minutes were derived from the axial force ratios 0.6 and 0.7. In addition, it was confirmed that the fire resistance time according to the axial force ratio calculated according to the reference equation (Eurocode 4) was lower than the actual experimental value. However, it was confirmed that the standard(Eurocode 4) was higher than the experimental value at the axial force ratio of 0.7. Accordingly, it is possible to confirm the fire resistance characteristics(time-axial force ratio relationship) of the SRC column at high axial force, and to use the experimental and anaylsis data of the SRC column as the data for verification based on Eurocode.

Intraoperative fluid therapy for video-assisted ovariohysterectomy in dogs

  • Oliveira, Marilia Teresa de;Feranti, Joao Pedro Scussel;Coradini, Gabriela Pesamosca;Chaves, Rafael Oliveira;Correa, Luis Felipe Dutra;Linhares, Marcella Teixeira;Thiesen, Roberto;Silva, Marco Augusto Machado;Brun, Mauricio Veloso
    • Journal of Veterinary Science
    • /
    • v.22 no.3
    • /
    • pp.44.1-44.15
    • /
    • 2021
  • Background: Intraoperative fluids are still poorly studied in veterinary medicine. In humans the dosage is associated with significant differences in postoperative outcomes. Objectives: The aim of this study is to verify the influence of three different fluid therapy rates in dogs undergoing video-assisted ovariohysterectomy. Methods: Twenty-four female dogs were distributed into three groups: G5, G10, and G20. Each group was given 5, 10, and 20 mL·kg-1·h-1 of Lactate Ringer, respectively. This study evaluated the following parameters: central venous pressure, arterial blood pressure, heart rate, respiratory rate, temperature, acid-base balance, and serum lactate levels. Additionally, this study evaluated the following urinary variables: urea, creatinine, protein to creatinine ratio, urine output, and urine specific gravity. The dogs were evaluated up to 26 h after the procedure. Results: All animals presented respiratory acidosis during the intraoperative period. The G5 group evidenced intraoperative oliguria (0.80 ± 0.38 mL·kg-1·h-1), differing from the G20 group (2.17 ± 0.52 mL·kg-1·h-1) (p = 0.001). Serum lactate was different between groups during extubation (p = 0.036), with higher values being recorded in the G5 group (2.19 ± 1.65 mmol/L). Animals from the G20 group presented more severe hypothermia at the end of the procedure (35.93 ± 0.61℃) (p = 0.032). Only the members of the G20 group presented mean potassium values below the reference for the species. Anion gap values were lower in the G20 group when compared to the G5 and G10 groups (p = 0.017). Conclusions: The use of lactated Ringer's solution at the rate of 10 mL·kg-1·h-1 seems to be beneficial in the elective laparoscopic procedures over the 5 or 20 mL·kg-1·h-1 rates of infusion.