• Title/Summary/Keyword: Reference contact area

Search Result 24, Processing Time 0.031 seconds

Genetic analyses of Acanthamoeba isolates from contact lens storage cases of students in Seoul, Korea

  • Yu, Hak-Sun;Choi, Kyung-Hee;Kim, Hyo-Kyung;Kong, Hyun-Hee;Chung, Dong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.39 no.2
    • /
    • pp.161-170
    • /
    • 2001
  • We conducted both the small subunit ribosomal DNA (SSU rDNA) polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and mitochondrial (mt) DNA RFLP analyses for a genetic characterization of Acanthamoeba isolates from contact lens storage cases of students in Seoul, Korea. Twenty-three strains of Acanthamoeba from the American Type Culture Collection and twelve clinical isolates from Korean patients were used as reference strains. Thirty-nine isolates from contact lens storage cases were classified into seven types (KA/LS1 , KA/LS2, KA/LS4, KA/LS5, KA/LS7 KA/LS18, KA/LS31). Four types (KA/LS1 , KA/LS2, KA/LS5, KA/LS18) including 33 isolates were regarded as A. castellanii complex by riboprints. KA/LS1 type was the most predominant (51.3%) in the present survey area, followed by KA/LS2 (20.9%), and KA/LSS (7.7%) types. Amoebae of KA/LS1 type had the same mtDNA RFLP and riboprint patterns as KA/E2 and KA/E12 strains, clinical isolates from Korean keratitis patients. Amoebae of KA/LS2 type had the identical mtDNA RFLP patterns with A. castellanii Ma strain, a corneal isolate from an American patient as amoebae of KA/LS5 type, with KA/E3 and KA/E8 strains from other Korean keratitis patients. Amoebae of KA/LS 18 type had identical patterns with JAC/E1, an ocular isolate from a Japanese patient. Three types , which remain unidentified at species level, were not corresponded with any clinical isolate in their mtDNA RFLP and riboprint patterns. Out of 39 isolates analyzed in this study, mtDNA RFLP and riboprint patterns of 33 isolates (84.6%) were identical to already known clinical isolates, and therefore, they may be regarded as potentially keratopathogenic. These results suggest that contact lens wearers in Seoul should pay more attention to hygienic maintenance of contact lens storage cases for the prevention of Acanthamoeba keratitis.

  • PDF

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING (기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구)

  • Choi, Su-Jin;Chee, Young-Deok;Koh, Se-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

A COMPARATIVE STUDY OF THE AMOUNT OF DISPLACEMENT AND OCCLUSION FORMS IN THE CHANGE FROM CR TO CO (중심위 교합에서 중심 교합으로 전위될 때의 변위량과 교합형태에 관한 비교 연구)

  • Lee, Jae-Bong;Shin, Cheol-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • Statement of problems: The concept of CR has also changed continuously.?In order to find out the factors that affect the centric slide, studies were carried out to compare the forms of wisdom teeth eruption, lateral movement, premature contact in CR, and anterior movement. Research and statistical methods were based on the report by the 1980 Korean dental association. Material and method: In our study, 403 dentists in their twenties and dentistry students who could understand CR and CO (and who did not receive occlusal, orthodontic treatment, without extreme caries and large prosthodontic care) were compared with the 25 year old results. A segment of line parallel to the upper incisor was marked on the lower incisor. When seen laterally, a line perpendicular to the occlusal plane was drawn on the foremost area of the upper incisor. This line was extended to the lower incisor and the two points (points at the lower and upper incisors) were used as reference points for the CO. After guiding the occlusion to the CR, two lines were marked by using the same method that was used for the CO. The point in which these lines meet became the reference point of CR occlusion Results and conclusions: Results of the experiment completed in 1980 show that all 307 research members had anterior-posterior and upper-lower displacement. Displacement measurements were $0.7{\pm}0.4mm$ for the anterior-posterior displacement, $0.99{\pm}0.50mm$ for the upper-lower displacement,0.18{\pm}0.31 mm for the lateral displacement, and $1.32{\pm}0.67mm$ for the total displacement. Results of the 2006 experiment show that all 409 research members had anterior-posterior and upper-lower displacement. The anterior-posterior displacement was $1.12{\pm}0.86mm$, the upper-lower displacement was $1.02{\pm}0.71mm$, the lateral displacement was $0.61{\pm}0.56mm$, and the total displacement was $1.80{\pm}0.99mm$. No specific differences were found between each group when comparing displacement according to the forms of wisdom teeth eruption. Since 1980, the percentage of unerupted teeth has increased from 35.16% (111/307 people) to 57.5% (236/409 people). Westernization of the Korean cranial form and intraoral structure has brought about these results. In our experiment, 26.7% (109/409 people) of the subjects were cuspid guided, while 7.3% (30/409 people) were mutually guided. No specific differences were found in the amount of displacement between the two groups. Only the subjects with anteriors coming in contact made up the largest percentage group (42.3%, 173/409 people) in our study. No specific differences were found between each group.

Human Dermal Risk Assessment on Chlorpyrifos of Korean Farmers (우리나라 농민의 Chlorpyrifos에 대한 피부 위해성 평가)

  • 정경미;이효민;이은희;이선희;김진화;심영용;홍진태;이용욱
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.3
    • /
    • pp.187-198
    • /
    • 2002
  • Chlorpyrifos is an organophosphate insecticide and one of the most commonly and widely used insecticide. However, a little known about the dermal risk of chlorpyrifos on human being. Therefore, this study was conducted for the dermal risk assessment after exposure to chlorpyrifos in Korean farmers. First, skin irritation by chlorpyrifos (10 mg/$\textrm{cm}^2$, 50 mg/$\textrm{cm}^2$, 100 mg/$\textrm{cm}^2$, 250 mg/$\textrm{cm}^2$ in acetone) was determined in rabbits for 5 days considering the usage of chlorpyrifos short term highly exposure. The index of skin irritation by chlorpyrifos was increased in each dose and length of exposure dependent manners. Next, using benchmark dose (BMD$_{5}$) approach, the dose-response relationship was assessed to calculate the reference dose (RfD). The value of RfD was 2.84 $\mu\textrm{g}$/kg/day from 142.16 $\mu\textrm{g}$/kg/day BMD5 value divided uncertainty factor 50. Finally, we assessed human dermal risk of chlorpyrifos with exposure level and RfD. Skin absorbed levels were assumed with several exposure scenarios encounting the circumstances of exposure that application method, protection equipment and cloth, exposure time and exposure frequency during chlorpyrifos spraying. By the comparison of skin absorbed dose with the reference dose, it was identified that risk values (risk index) to skin chlorpyrifos exposure were 0.958 from the point of above results and it was recommended that the occurrence of hazard effect (skin irritation toxicity) of chlorpyrifos would not be expected. Risk index was smaller than 1 in the case of spraying vehicle mounted application, 1hour exposure time and wearing protective cloth exposure. Whereas, risk index was above 1 in the case of hand-held application, 2hour exposure time and wearing common cloth. Comparing two kinds of application method, total risk index of the hand held application (1.67) was higher than vehicle mounted (0.27). Therefore, chlorpyrifos skin exposure was mainly affected by application equipment and applied form. The results of risk assessment on the human dermal toxicity of chlorpyrifos should be required to control in keeping safety rules, skin surface area available for contact, spraying time ,and spraying frequency.y.

  • PDF

Analysis of patent trends of computerized tongue diagnosis systems (설진 시스템 특허동향 분석)

  • Jung, Chang Jin;Lee, Yu Jung;Kim, Jaeuk U.;Kim, Keun Ho
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.2
    • /
    • pp.77-89
    • /
    • 2013
  • Objectives Tongue diagnosis is an important diagnostic method in traditional Eastern medicine, and it has a high potential to be used in the future healthcare because of easy, quick, and non-contact measuring features. Recently, research and development efforts on computerized tongue diagnosis systems (CTDS) have been active that led to the technical advancements in the field of photographing techniques, image extraction and classification algorithms. In this study, we analyzed the trends in the CTDS patents. Using the WIPS search engine (www.wipsglobal.com), quantitative and qualitative patent analyses were performed through Korea, China, Japan, U.S.A and Europe. Methods For a systematic search and data analysis, we defined patent categories based on the application area and technical details. By applying thus-obtained categorical key words, we obtained 360 relevant patents on photographing techniques, image extraction and classification algorithms for the purpose of diagnosis or security. Results As a result, companies related to image acquisition, medical imaging and mobile devices and research groups of universities in East Asia were major patent applicants. In all the five countries, the number of patents have been increasing since 1980. In particular, technology related to color correction and image segmentation were most actively patented categories, and expected to continue a high application rate.

Development of a process to apply uniform pressure to bond CFRP patches to the inner surface of undercut-shaped sheet metal parts (언더컷 형상의 판재 성형품에 보강용 CFRP 패치의 접합을 위한 공정기술 개발)

  • Lee, Hwan-Ju;Jeon, Yong-Jun;Cho, Hoon;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.65-70
    • /
    • 2020
  • Partial reinforcement of sheet metal parts with CFRP patch is a technology that can realize ultra-lightweight body parts while overcoming the high material cost of carbon fiber. Performing these patchworks with highly productive press equipment solves another issue of CFRP: high process costs. The A-pillar is the main body part and has an undercut shape for fastening with other parts such as roof panels and doors. Therefore, it is difficult to bond CFRP patches to the A-pillar with a general press forming tool. In this paper, a flexible system that applies uniform pressure to complex shapes using ceramic particles and silicone rubber is proposed. By benchmarking various A-pillars, a reference model with an undercut shape was designed, and the system was configured to realize a uniform pressure distribution in the model. The ceramic spherical particles failed to realize the uniform distribution of high pressure due to their high hardness and point contact characteristics, which caused damage to the CFRP patch. Compression equipment made of silicone rubber was able to achieve the required pressure level for curing the epoxy. Non-adhesion defects between the metal and the CFRP patch were confirmed in the area where the bending deformation occurred. This defect could be eliminated by optimizing the process conditions suitable for the newly developed flexible system.

Hydrophobic Organic/Inorganic Composite Films with 3D Hierarchical Nanostructured Surfaces (3D 계층적 나노구조화된 표면을 갖는 소수성 유/무기 복합 필름)

  • Seo, Huijin;Ahn, Jinseong;Park, Junyong
    • Composites Research
    • /
    • v.34 no.4
    • /
    • pp.264-268
    • /
    • 2021
  • In this study, we propose a method for fabricating hydrophobic coatings/films with three-dimensional (3D) hierarchical nanostructured organic/inorganic composite surfaces. An epoxy-based, large-area 3D ordered nanoporous template is first prepared through an advanced photolithography technique called Proximity-field nanoPatterning (PnP). Then, a hierarchically structured surface is generated by densely impregnating the template with silica nanoparticles with an average diameter of 22 nm through dip coating. Due to the coexisting micro- and nano-scale roughness on the surface, the fabricated composite film exhibits a higher contact angle (>137 degrees) for water droplets compared to the reference samples. Therefore, it is expected that the materials and processes developed through this study can be used in various ways in the traditional coating/film field.

A FRONTAL CEPHALOMETRIC STUDY ON THE REFERENCE LINES TO ASSESS THE CRANIOMAXILLOFACIAL ASYMMETRY (안면 비대칭의 평가를 위한 기준에 관한 정모 두부 방사선 계측학적 연구)

  • Paek, Sun-Ho;Ahn, Byoung-Keun;Kim, Sun-Hae;Sohn, Hong Bum;Han, Ho Jin;Kang, Soo-Man
    • The korean journal of orthodontics
    • /
    • v.23 no.1 s.40
    • /
    • pp.1-15
    • /
    • 1993
  • This study was undertaken to investigate the midline having the least difference between the right and left structures among the lines that had been used in the study of the craniomaxillofacial asymmetry. The sample of this study consisted of twenty six Korean girls(average 18.9 years old) having normal facial appearance and occlusion. On the frontal cephalometric films of the sample, we divided the whole craniomaxillofacial area into four portions, i.e., cranial, upper facial, lower facial, and dental portion. So, we have found the midlines having the least difference in the whole craniomaxillofacial area itself, and in the each divided four portions, furtherly in the other portions from aimed portion. The findings were as follow: 1. In the whole craniomaxillofacial area, the connecting line between crista galli and anterior nasal spine and the perpendicular bisecting line between right and left foramen rotundums were suitable for the midline. 2. In the cranial portion, established all six lines were suitable for midlines. In the other portions, the perpendicular bisection line between both condylion, the line passing the contact point between right and left mandibular central insisiors among the perpendicular lines between right and left mandibular central incisial tips were suitable midlines fer evaluating the asymmetry of cranial portion. 3. In the upper facial portion, the perpendicular bisecting line between right and left zygions was the most suitable midline. In the other portions, the line between the crista galli and the most superior point of the odontoid process, the perpendicular bisecting line between right and left gonions, the perpendicular bisecting line between right and left condylions, and perpendicular bisecting line between right and left foramens rotundum were suitable midlines for evaluating the asymmetry of the upper facial portion 4. In the dental portion, the perpendicular bisecting lines between right and left buccal cusps of both maxillary first molars and between right and left mandibular first molars were suitable midlines. In the other portions, the perpendicular bisecting line between right and left landmarks crossing the lesser wing of the sphenoid bone and orbit, the perpendicular bisecting line between right and left mental foramens, and the connecting line between crista galli and prosthion were suitable midlines for evaluating the asymmetry of dental portion. 5. In the lower facial portion, the perpendicular bisecting lines between right and left condylions and between right and left gonions were suitable midlines. In the other portions, the line between the crista galli and anterior nasal spine, the perpendicular bisecting line between right and left foramen rotundums, and the perpendicular bisecting lines between right and left buccal cusps of both mandibular first molars and between right and left maxillary first molars were suitable midlines for evaluating the asymmetry of the lower facial portion.

  • PDF