• Title/Summary/Keyword: Reference Temperature

Search Result 1,261, Processing Time 0.025 seconds

Color Temperature Conversion Method Using Reference White Region Estimation

  • Do, Hyun-Chul;Chien, Sung-Il;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.872-875
    • /
    • 2002
  • This paper presents an efficient method of estimating the correlated color temperature of an input color image and of generating a converted color image that can approximate the new target color temperature. After extracting the potential reference white region for an uncalibrated color image and estimating its correlated color temperature, the color conversion method produces a new color image with a target color temperature. Speed improvement and memory reduction have been achieved by using a simple transfer method without involving the CIE XYZ conversion step.

  • PDF

A temperature and supply insensitive CMOS current reference using a square root circuit (제곱근 회로를 이용한 온도와 공급 전압에 둔감한 CMOS 정전류원)

  • 이철희;손영수;박홍준
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.12
    • /
    • pp.37-42
    • /
    • 1997
  • A new temperature and supply-insensitive CMOS current reference circuit was designed and tested. Te temperature insensuitivity was achieved by eliminating the mobility dependence term through the multiplication of two current components, one which is proportional to mobility and the other which is inversely proportional to mobility, by using a newly designed CMOS square root circuit. The CMOS sqare root circuit was derived from its bipolar counterpart by operating the MOS transistors in the subthreshold region. The supply insensitivity was achieved by using an internal voltage generator. Te test chip was designed ans sent out for fabrication by using a 2.mu.m double-poly double-metal n-well CMOS technology. When an external voltage source was used for the square root circuit, the maximum variation and the average temperature sensitivity were measured to be 3% and 21.4ppm/.deg.C, respectively, for the temperature range of -15~130.deg.C. The maximum current variation with supply voltage was measured to be 3% within the commerical supply voltage range of 4.5~5.5V at 30.deg. C.

  • PDF

Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method (능동열시험법을 이용한 몰드변압기 진단)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

Reference intervals of hematological and histopathological index at three different temperatures in Korean rockfish Sebastes schlegelii (조피볼락의 수온별 혈액학적 및 병리조직학적 정상치 탐색)

  • Beom Hee Lee;Sang Bin Lee;Eul Bit Noh;Ji Min Ryu;Bo Seong Kim
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.369-378
    • /
    • 2023
  • In this study, clinically healthy Korean rockfish were provided by a farm and then raised in a lab for 14 days at three different temperatures (10℃, 15℃, and 20℃) to establish hematological, blood biochemical, and histopathological reference intervals against normal fish. Hematocrit, MCV, MCHC, total protein, BUN, and GPT values in the blood showed significant differences among temperature groups. As the water temperature increased, neutrophil, thrombocyte, and lymphocyte counts also rose, while the monocyte value peaked at 15℃. The histopathological score revealed significant variations in the gills, stomach, and inflammation indices by temperature group; the gills and inflammation indices peaked at 20℃, whereas the stomach index peaked at 15℃. It is expected that information on these normal values will serve as a fundamental collection of data for further studies related to laboratory-based experiments.

Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors (대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선)

  • Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.

A Quartz Tube Based Ag/Ag+ Reference Electrode with a Tungsten Tip Junction for an Electrochemical Study in Molten Salts

  • Park, Y.J.;Jung, Y.J.;Min, S.K.;Cho, Y.H.;Im, H.J.;Yeon, J.W.;Song, K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.133-136
    • /
    • 2009
  • A newly designed Ag/$Ag^+$ reference electrode in a quartz tube with a tungsten tip junction (W-tip-Quartz- REF) was fabricated and its electrochemical performance was compared with a conventional Pyrex tube-based Ag/$Ag^+$ reference electrode (Py-REF). The results of the electrochemical potential measurements with the W-tip-Quartz- REF and the Py-REF in the LiCl-KCl eutectic melts for a wide temperature range proved that the oxide layer on the surface of the tungsten metal tip provided a high ionic conduction. Stability of our newly designed W-tip- Quartz-REF was tested by measuring a junction potential for 12 hours at 700${^{\circ}C}$. The results of the cyclic voltammetric measurement indicated that the Ag/$Ag^+$ reference electrode in the quartz tube with a tungsten tip junction can provide a good performance for a wide temperature range.

Bandgap Voltage Reference Circuit Design Technology Suitable for Driving Large OLED Display Panel (대형 OLED 디스플레이 패널 구동에 적합한 밴드갭 레퍼런스 회로 설계 및 결과)

  • Moon, Jong Il;Cho, Sang Jun;Cho, Eou Sik;Nam, Chul;Kwon, Sang Jik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.2
    • /
    • pp.53-56
    • /
    • 2018
  • In this paper, a CMOS bandgap voltage reference that is not sensitive to changes in the external environment is presented. Large OLED display panels need high supply voltage. MOSFET devices with high voltage are sensitive to the output voltage due to the channel length modulation effect. The self-cascode circuit was applied to the bandgap reference circuit. Simulation results show that the maximum output voltage change of the basic circuit is 77mV when the supply voltage is changed from 10.5V to 13.5V, but the proposed circuit change is improved to 0.0422mV. The improved circuit has a low temperature coefficient of $9.1ppm/^{\circ}C$ when changing the temperature from $-40^{\circ}C$ to $140^{\circ}C$. Therefore, the proposed circuit can be used as a reference voltage source for circuits that require a high supply voltage.

Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by using Infrared Sensor for Compensation (보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성)

  • Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.124-130
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was built with ASIC implemented thermopile sensor which included temperature sensor and unique elliptical waveguide structures in this paper. The temperature dependency of dual infrared sensor module ($CO_2$ and reference IR sensors) has been characterized and its output voltage characteristics according to the temperature and gas concentration were proposed for the first time. NDIR $CO_2$ gas and reference IR sensors showed linear output voltages according to the variation of ambient temperatures from 243 K to 333 K and their slopes were 14.2 mV/K and 8.8 mV/K, respectively. The output voltages of temperature sensor also presented a linear dependency according to the ambient temperature and could be described with V(T)=-3.191+0.0148T(V). The output voltage ratio between $CO_2$ and reference IR sensors revealed irrelevant to the changes of ambient temperatures and gave a constant value around 1.6255 with standard deviation 0.008 at 0 ppm. The output voltage of $CO_2$ gas sensor at zero ppm $CO_2$ gas consisted of two components; one is caused by the HPB (half pass-band) of IR filter and the other is attributed to the part of $CO_2$ absorption wavelength. The characteristics of output voltages of $CO_2$ gas sensor could be accurately modeled with three parameters which are dependent upon the ambient temperatures and represented small average error less than 1.5% with 5% standard deviation.

Silicon Oil-Based 2-Channel Fiber-Optic Temperature Sensor Using a Subtraction Method (감법을 이용한 실리콘 오일 기반의 2채널 광섬유 온도 센서)

  • Lee, Dong Eun;Yoo, Wook Jae;Shin, Sang Hun;Kim, Mingeon;Song, Young Beom;Kim, Hye Jin;Jang, Kyoung Won;Tack, Gye Rae;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.344-348
    • /
    • 2016
  • We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a singlemode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to $70^{\circ}C$. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.