Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.

Accuracy Analysis of GPS Virtual Reference Station's Data (GPS 가상기준점 자료의 정확도 분석)

  • 이용창
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.91-96
    • /
    • 2004
  • More recently, multiple reference based RTK GPS techniques(VRS : Virtual Reference System) are becoming increasingly important for many precise GPS applications in many countries to overcome the constrained distance limitations of standard RTK systems. The precision of the position solutions of the rover receiver is closely connected with that of the corresponding virtual reference points(VRPs). The objective of this paper is to investigate the accuracy and performance of the VRPs on the test network for static positioning in post processing mode. For this, some VRPs at the inside and outside of test network have made in post mode, and the overall analysis results were presented by comparing the solution for the VRPs from the existed GPS reference station with the true values of the coordinates used to produce the observation data. The results show the reasonable accuracies of VRPs in the network area by using the VRS concept in post mode.

  • PDF

Performance Evaluation of a BACnet-based Fire Detection and Monitoring System for use in Buildings

  • Song Won-Seok;Hong Seung-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • The objective of this paper is to propose a reference model of a fire detection and monitoring system using MS/TP protocol. The reference model is designed to satisfy the requirements of response time and flexibility. The reference model is operated on the basis of BACnet, a standard communication protocol for building automation systems. Validity of the reference model was examined using a simulation model. This study also evaluated the performance of the BACnet-based fire detection and monitoring system in terms of network-induced delay. Simulation results show that the reference model satisfies the requirements of the fire detection and monitoring system.

A study on a CMOS analog cell-library design-A CMOS on-chip current reference circuit (CMOS 아날로그 셀 라이브레이 설계에 관한 연구-CMOS 온-칩 전류 레퍼런스 회로)

  • 김민규;이승훈;임신일
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.136-141
    • /
    • 1996
  • In this paper, a new CMOS on-chip current reference circit for memory, operational amplifiers, comparators, and data converters is proposed. The reference current is almost independent of temeprature and power-supply variations. In the proposed circuit, the current component with a positive temeprature coefficient cancels that with a negative temperature coefficient each other. While conventional curretn and voltage reference circuits require BiCMOS or bipolar process, the presented circuit can be integrated on a single chip with other digiral and analog circits using a standard CMOS process and an extra mask is not needed. The prototype is fabricated employing th esamsung 1.0um p-well double-poly double-metal CMOS process and the chip area is 300um${\times}$135 um. The proposed reference current circuit shows the temperature coefficient of 380 ppm/.deg. C with the temperature changes form 30$^{\circ}C$ to 80$^{\circ}C$, and the output variation of $\pm$ 1.4% with the supply voltage changes from 4.5 V to 5.5 V.

  • PDF

Fast Multiple Reference Frame Selection for H.264 Encoding (H.264 부호화를 위한 고속 다중 참조 화면 결정 기법)

  • Jeong, Jin-Woo;Cheo, Yoon-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.419-420
    • /
    • 2006
  • In the new video coding standard H.264/AVC, motion estimation (ME) is allowed to search multiple reference frames for improve the rate-distortion performance. The complexity of multi-frame motion estimation increases linearly with the number of used reference frame. However, the distortion gain given by each reference frame varies with the video sequence, and it is not efficient to search through all the candidate frames. In this paper, we propose a fast mult-frame selection method using all zero coefficient block (AZCB) prediction and sum of difference (SAD) of neighbor block. Simulation results show that the speed of the proposed algorithm is up to two times faster than exhaustive search of multiple reference frames with similar quality and bit-rate.

  • PDF

The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor (보정계수 산출에 의한 신광원용 표준램프 광속의 검증)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Yi, Chin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.