• Title/Summary/Keyword: Reference Beam

Search Result 517, Processing Time 0.039 seconds

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

Optical Decryption System of Binary Image Using Two-Wave Mixing in Photorefractive Crystal (광굴절 매질에서 2광파 혼합을 이용한 이진 영상 복호화 시스템)

  • 최상규;신창목;서동환;김철수;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.207-210
    • /
    • 2002
  • We suggest binary image decryption system using two-wave mixing in photorefractive crystal. Compared with a conventional method, this method can make optical alignment easily, and brighten the encrypted image even if a small input signal, by index grating of photorefractive crystal. Also it can reconstruct the encrypted image by only reference beam in real time.

  • PDF

MOLECULAR LINE OBSERVATIONS TOWARD THE COMPACT HII REGIONS IN W58

  • MINH Y. C.;ROH D. G.;KIM H. R.
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.1
    • /
    • pp.55-60
    • /
    • 1994
  • The 3mm transitions to CO, $^{13}CO,\;CS,\;HCO^+$, and HCN have been observed toward the compact HII regions in W58 using the 14m Daeduk Radio Telescope (DRT). Some of the observed lines show high-velocity wings resulted from outflowing materials of the compact HII regions. We derive the beam averaged column densities of the observed species and compare their relative abundances. The $HCO^+$ abundance appears to be smaller by about an order of magnitude than those of 'typical' quiet molecular clouds. CS may be a good reference molecule in comparing relative abundances in different physical conditions.

  • PDF

A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy (방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정)

  • Gha-Jung, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.719-725
    • /
    • 2022
  • This study aimed to measure, quantitatively evaluate, and set the criteria for the minimum lead(Pb) shield thickness per level of clinically applied electron beam energy. The lead shield thickness per electron beam energy was measured using the primary field 95% reduction based on the open field at the depth of maximum dose (dmax) and depth from the surface as the reference depth of tissue dose(10 mm). The measured values were 1.906 mmPb and 1.992 mmPb at the dmax and 10 mm, respectively, regarding the lead shield thickness for 6 MeV electron beam; 2.746 mmPb and 3.743 mmPb for 9 MeV electron beam, 3.718 mmPb and 6.093 mmPb for 12 MeV electron beam, 7.300 mmPb and 15.270 mmPb for 16 MeV electron beam, and 16.825 mmPb and 25.090 mmPb for 20 MeV electron beam. Consequently, a thicker lead shield was required if the measurement was at 10 mm. The required lead shield thickness was also higher than that of the theoretical formula for electron beams of ≥ 16 MeV.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Calculation on Pure Sediment Volume at Namgang Dam Basin by Echo-sounder based on NTRIP Service (NTRIP 기반 음향측심기를 이용한 남강댐 유역의 순퇴적량 산정)

  • Lee, Suk-Bae;Kim, Ki-Heung;Park, Jae-Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.251-257
    • /
    • 2013
  • Bathymetry sounding or water depth measurement is becoming more and more sophisticated with the increasing demand in accuracy, resolution and coverage in the recent years. Single beam echo sounding is still utilized to gather single line bathymetric profile in many surveys as ever, although there is an increasing demand for multi-beam echo sounding. Single beam echo sounder system acquires single line profiles of water depth as the vessel travel along the survey line. In this study, we performed single beam echo sounding with GNSS receiver for hydrographic survey at Namgang dam basin to calculate pure sediment. Unlike traditional research, we used not field reference station but NTRIP service of the reference station of DGNSS(Differential Global Navigation Satellite System) Central Office in this GNSS survey. The calculation results show that scouring volume is $603,650m^3$, sediment volume is $3,913,750m^3$ and so pure sediment volume is $3,310,100m^3$ at Namgang dam basin. And the availability of the NTRIP service of the DGNSS Central Office for echo sounding in land area has been confirmed in this study.

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

Crown and root lengths of incisors, canines, and premolars measured by cone-beam computed tomography in patients with malocclusions

  • Kim, Seon-Young;Lim, Sung-Hoon;Gang, Sung-Nam;Kim, Hee-Jin
    • The korean journal of orthodontics
    • /
    • v.43 no.6
    • /
    • pp.271-278
    • /
    • 2013
  • Objective: The purposes of this study were to determine the accuracy of crown and root length measurements of premolars using cone-beam computed tomography (CBCT) and to generate reference CBCT-based data on incisor, canine, and premolar lengths in patients with malocclusions. Methods: Imaging was performed using a CBCT scanner with a 0.292-mm voxel size and 12-bit grayscale. The CBCT-based length measurements were compared with direct measurements of 94 subsequently extracted premolars without metal restorations using the paired t-test. Furthermore, the crown and root lengths of incisors, canines, and premolars in 62 Korean patients with malocclusions were measured using CBCT, and Pearson's correlation coefficients were calculated to examine the relationship between the crown and root length measurements of each tooth type. Results: The differences between the CBCT-based and direct measurements of the extracted premolars were not significant, with 95% limits of agreement of -0.90 to 0.90 mm for crown length and -1.23 to 1.18 mm for root length. Weak positive correlations between the crown and root length measurements were observed for the mandibular canine and premolars. Conclusions: The CBCT-based measurements showed a wider range of limits of agreements for root length than for crown length. The CBCT-based data can be used as a reference for evaluating root length and resorption of teeth without metal restorations in patients with malocclusions.

Three-dimensional evaluation of midfacial asymmetry in patients with nonsyndromic unilateral cleft lip and palate by cone-beam computed tomography

  • Choi, Youn-Kyung;Park, Soo-Byung;Kim, Yong-Il;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.113-119
    • /
    • 2013
  • Objective: To compare three-dimensionally the midfacial hard- and soft-tissue asymmetries between the affected and the unaffected sides and determine the relationship between the hard tissue and the overlying soft tissue in patients with nonsyndromic complete unilateral cleft lip and palate (UCLP) by cone-beam computed tomography (CBCT) analysis. Methods: The maxillofacial regions of 26 adults (18 men, 8 women) with nonsyndromic UCLP were scanned by CBCT and reconstructed by three-dimensional dental imaging. The frontal-view midfacial analysis was based on a $3{\times}3$ grid of vertical and horizontal lines and their intersecting points. Two additional points were used for assessing the dentoalveolar area. Linear and surface measurements from three reference planes (Basion-perpendicular, midsagittal reference, and Frankfurt horizontal planes) to the intersecting points were used to evaluate the anteroposterior, transverse, and vertical asymmetries as well as convexity or concavity. Results: Anteroposteriorly, the soft tissue in the nasolabial and dentoalveolar regions was significantly thicker and positioned more anteriorly on the affected side than on the unaffected side (p < 0.05). The hard tissue in the dentoalveolar region was significantly retruded on the affected side compared with the unaffected side (p < 0.05). The other midfacial regions showed no significant differences. Conclusions: With the exception of the nasolabial and dentoalveolar regions, no distinctive midfacial hard- and soft-tissue asymmetries exist between the affected and the unaffected sides in patients with nonsyndromic UCLP.

Seismic design of chevron braces cupled with MRF fail safe systems

  • Longo, Alessandra;Montuori, Rosario;Piluso, Vincenzo
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1215-1240
    • /
    • 2015
  • In this paper, the Theory of Plastic Mechanism Control (TPMC) is applied to the seismic design of dual systems composed by moment-resisting frames and Chevron braced frames. The application of TPMC is aimed at the design of dual systems able to guarantee, under seismic horizontal forces, the development of a collapse mechanism of global type. This design goal is of primary importance in seismic design of structures, because partial failure modes and soft-storey mechanisms have to be absolutely prevented due to the worsening of the energy dissipation capacity of structures and the resulting increase of the probability of failure during severe ground motions. With reference to the examined structural typology, diagonal and beam sections are assumed to be known quantities, because they are, respectively, designed to withstand the whole seismic actions and to withstand vertical loads and the net downward force resulting from the unbalanced axial forces acting in the diagonals. Conversely column sections are designed to assure the yielding of all the beam ends of moment-frames and the yielding and the buckling of tensile and compressed diagonals of the V-Braced part, respectively. In this work, a detailed designed example dealing with the application of TPMC to moment frame-chevron brace dual systems is provided with reference to an eight storey scheme and the design procedure is validated by means of non-linear static analyses aimed to check the actual pattern of yielding. The results of push-over analyses are compared with those obtained for the dual system designed according to Eurocode 8 provisions.