• Title/Summary/Keyword: Reference Analysis

Search Result 6,558, Processing Time 0.033 seconds

UAV Photogrammetry Accuracy Analysis at Marine Using Arbitrary Reference Points (임의의 기준점을 이용한 해상에서의 UAV 사진측량 정확도 분석)

  • Oh, Jae Hyun;Kim, Byung Woo;Hwang, Dae Young;Hong, Soon Heon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.39-45
    • /
    • 2016
  • In this study, with arbitrary reference points on the water, photogrammetry accuracy analysis was conducted using unmanned aerial vehicle(UAV). A small reservoir is a research area, and twenty buoys were used as arbitrary reference points. Errors of location coordinate were identified with control of amounts of used reference points. cases are categorized by index scores per photos. Accuracy of X is 0.141m~0.166m and accuracy of Y is 0.136m~0.241m. Considering that allowable error for the maritime boundary survey is ${\pm}2m$, it is possible to get the accuracy data available for the photogrammetry of UAV using an reference point. In addition, the coefficient of correlation between the number of reference points per unit and number of buoys used as reference point and the ratio of the reference point per square measure, and percentage of buoys used as reference point and the coefficient of x and y were performed. Each element, x, and y showed a strong correlation and the coefficient of number of buoys used as reference point was irrelevant. The results of this correlation analysis can be analyzed that the number of reference points used in each picture is greater than the actual number of reference points used in location accuracy.

A Reference Value for Cook's Measure

  • Lee, Jae-Jun
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 1999
  • A single outlier can influence on the least squares estimators and can invalidate analysis based on these estimators. The Cook's statistic has been introduced to measure influence of individual data point on parameter estimation and the quantile of the F distribution is recommended as a reference value. but in practice subjective judgement is applied in the choice of appropriate quantile. A simple reference value is introduced in this paper which is developed by approximating conditional quantities of Cook's measure. The performance of the proposed criterion is evaluated through analysis of real data set.

  • PDF

Performance Analysis of WADGPS System for Improving Positioning Accuracy

  • So, Hyoungmin;Jang, Jaegyu;Lee, Kihoon;Park, Junpyo;Song, Kiwon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • The Wide Area Differential Global Positioning System (WADGPS) that uses a number of Global Navigation Satellite System (GNSS) reference stations are implemented with various types and provide services as it can service a wide range of areas relatively. This paper discusses a constellation design of reference stations and performance analysis of the WADGPS. It presented performance results of static and dynamic users when wide area correction algorithm was applied using eight reference stations.

Development of certified reference material (CRM)s for surface analysis I : alloy thin film for surface compositional analysis (표면분석용 인증표준물질의 개발 I : 표면조성분석용 합금박막 표준물질)

  • 김경중;박용섭;문대원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.276-282
    • /
    • 1999
  • For the quantitative surface analysis of multicomponent materials, algorithms for the compensation of the matrix effect and surface compositional change by ion beam sputtering must be established and reference materials having certified compositions are necessary. These certified reference material (CRM)s are needed for the improvement of instrument performance, inter-laboratory comparison and quantitative surface analysis. Surface analysis group of KRISS developed alloy thin film CRMs by and ion beam sputter deposition system and in-situ surface analysis system to control the composition of alloy thin films The real compositions of the CRMs were certified by inductively coupled plasma-atomic emission spectroscopy (ICP-AES).

  • PDF

Quantitative analysis of phosphorus by HERETIC-NMR method (HERETIC-NMR법을 이용한 인의 정량분석)

  • Lim, Heon-Sung;Park, Chan-Jo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.438-441
    • /
    • 2008
  • We have developed an alternative to the internal chemical reference based on a calibrated reference signal which is not a real NMR line but an electronically produced signal (HERETIC) and determined the phosphorus concentration using this method. The area ratio of HERETIC and sample peaks obtained from the standard samples was used to measure the concentrations of different samples directly. The analysis of phosphorus by this method showed the excellent linear regression coefficient ($R^2=0.9999$) for the concentration range from 20 ppm to 500 ppm with HERETIC peak as reference.

A Design of Content Delivery System with Analysis of the Web Object Reference Characteristics (웹 객체 참조 특성 분석을 통한 웹 기반 디지털콘텐트 전송시스템의 설계)

  • Na Yun ji;Ko Il seok;Cho Dong uk;Yu Won jong;Kwak Jong min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4C
    • /
    • pp.262-268
    • /
    • 2005
  • The unit of the digital content delivery is the web object. For the improvement of the content delivery based on the web, it id required analysis of reference characteristics of the web object. In this study, we analyze reference characteristics of the web object and evaluate the performance. Using these analysis results, we propose the digital content delivery system which is improved delivery efficiency. The goal of the proposed system are the improvement of the processing time through enhancement of the caching efficiency with reflect reference characteristics of the web object. And the experiment result, we verify the performance enhancement.

An Analysis of Differences on External Reference Price-ending and Consumer Satisfaction in Menu Products (메뉴 상품의 외적 준거 가격 끝수와 소비자 만족의 차이 분석)

  • Na, Tae-Kyun;Kim, Jang-Eix
    • Culinary science and hospitality research
    • /
    • v.13 no.2
    • /
    • pp.123-135
    • /
    • 2007
  • This study intended to determine how price-ending types used for menu products affected consumers' price evaluation and value perception and such behavioral intentions as purchase intention and search intention. The collected data went through statistical processing, including frequency analysis, factor analysis, T-test and ANOVA using an $SPSS/PC^+$ 12.0 statistical package. The results can be summarized as follows: First, as for differences in internal reference price by ending, internal reference price was lower if menu ending was an odd number than it was an even number, which indicates that consumers tend to consider the price of the menu products to be lower if the ending of menu products is an odd number. Second, menu price-ending was found to have significant differences on consumers' purchase intention, search intention, and value perception. But the results of two-way ANOVA showed that price ending by restaurant types had no effect on consumers' search intention and restaurant type. This study suggested a desirable external reference price-ending type for menu products as one of sales promotion strategies to menu products planners and drew up a concrete plan to determine which price-ending type is useful by consumers' personal properties.

  • PDF

Development of a Nutritional Supplement Certified Reference Material for Elemental Analysis

  • Lee, Jong Wha;Heo, Sung Woo;Kim, Hwijin;Lim, Youngran;Lee, Kyoung-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.105-109
    • /
    • 2018
  • A certified reference material (CRM) for the analysis of inorganic nutrients in nutritional supplements has been developed. Accurate mass fractions of chromium (Cr), iron (Fe), copper (Cu), and zinc (Zn) were determined by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). The measurement results were used to assign certified values for the CRM, which were metrologically traceable to the definitions of the measurement units in the International System of Units (SI). Production of a candidate reference material (RM) and the certification processes are summarized. Each nutrient in the CRM showed good homogeneity, which was estimated using relative standard deviations of the measurement results of twelve bottles in a batch. This CRM is expected to be an important reference to improve reliability and comparability of nutrient analyses in nutritional supplements and related samples in analytical laboratories.

Comparison Analysis of Resonant Controllers for Current Regulation of Selective Active Power Filter with Mixed Current Reference

  • Yi, Hao;Zhuo, Fang;Li, Yu;Zhang, Yanjun;Zhan, Wenda
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.861-876
    • /
    • 2013
  • Instead of extracting every selected harmonic component, the current reference of selective active power filter (APF) can be also obtained by filtering out the fundamental component from distorted load current for computation efficiency. This type of mixed current reference contains kinds of harmonic components and easily involves noises. In this condition, selective harmonic compensation must be realized by the current controller. With regard that selectivity is the most significant feature of controller, this paper presents specific comparison analysis between two types of resonant controllers: proportional-resonant (PR) controller and vector-resonant (VR) controller. The comparison analysis covers the relations, performances, and stability of both controllers. Analysis results conclude that the poorer selectivity of the PR controller could be relatively improved, but limitations from system stability make the improvement hardly realized. By contrast, the VR controller exhibits excellent selectivity and is more suitable for selective APF with mixed current reference. Experimental results from laboratory prototype validate the reasonability of analysis. And the features of each resonant controller are concluded.

A Study on the Standards Evaluation Method Using Standards Networks (표준 연결망을 활용한 표준의 평가방법에 관한 연구)

  • Choi, Jae Jin;Chung, Soon Suk;Kim, Kwang Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.2
    • /
    • pp.315-325
    • /
    • 2019
  • Purpose: The purpose of this study was to propose useful standards evaluation method using standards networks by analyzing the relationship between normative references citation information list. Methods: The collected data through the survey were analyzed using social network analysis. The measurement tools used for this study were divided into three dimensions such as certificate standard, normative reference and degree centrality. Results: The results of this study are as follows; regarding the influence of standard information, It is meaningful that the research using normative reference item among the bibliography information that the standard itself possesses. The analysis of social network analysis data of population standard, normative reference and the correlation analysis with sales, a variable representing actual utilization performance, suggested the importance of the standard and how to evaluate it. Conclusion: In prioritizing standard maintenance, more efficient management will be possible if centrality figures of standard network information are analyzed and used for standard maintenance.