• 제목/요약/키워드: Reference Analysis

검색결과 6,558건 처리시간 0.043초

참조응력 개념을 이용한 원주방향 관통균열 배관의 파괴 역학 해석 - 실배관 실험 데이터와의 비교 - (Reference Stress Based Fracture Mechanics Analysis for Circumferential Through-Wall Cracked Pipes - Comparison with Pipe Test Data -)

  • 허남수;심도준;김윤재;김영진
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.638-646
    • /
    • 2003
  • This paper presents experimental validation of the enhanced reference stress based J estimates for circumferential through-wall cracked pipes. recently proposed by authors. Using the pipe test data for circumferential through-wall cracked pipes, the predicted fracture initiation and maximum moments according to the proposed enhanced reference stress method are compared with experimental ones as well as predictions from the R6 method. The results show that both the R6 method and the proposed method give conservative estimates of initiation and maximum moments for circumferential through-wall cracked pipes, compared to experimental data. For longer cracks, the proposed method reduces conservatism embedded in estimated J according to the R6 method, and the resulting predictions are less conservative, compared to those from the R6 method. For shorter cracks, on the other hand, the proposed method reduces possible non-conservatism embedded in estimated J according to the R6 method, and the resulting predictions are slightly more conservative.

수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석 (Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

자연하천에서 하도의 물리적 특성과 하상재료의 상관관계분석 (Analysis of Correlation on Physical Characteristics and Bed Materials in Natural Rivers)

  • 김기흥
    • 한국환경복원기술학회지
    • /
    • 제13권2호
    • /
    • pp.95-104
    • /
    • 2010
  • The purpose of this study is to analyze the correlation between physical stream characteristics and bed materials in natural rivers. Accordingly, four natural rivers were selected reference streams, they were Nam river, Sumjin River, Naesung River and Han River. Grain size distributions of bed materials were gravels, cobbles and boulders in Han river and Nam river, were sand, gravels, cobbles and boulders in Sumjin river and were sand in Naesung river. Four reference streams were divided into each two reference reaches (straight and bend) by plan and profile characteristics of naturally meandering stream. Therefore various reference reaches were chosen in the aspect of physical stream characteristics and grain size distributions. The results investigated and analyzed are as follows. The streams that grain sizes distributions of river bed materials were coarse were stable because they had variety of bed slope without sediment deposition, and then the riffles frequency and the physical characteristics were various. Also, velocitydepth regime were various in four kinds, and the response parts for water level change were small, so that channel flow status were stable and excellent condition. On the other hand, sand river that grain sizes distributions of river bed materials were fine had not the variety of parameters as velocity-depth regimes, sediment deposition, channel flow status and riffles frequency, so that the physical stream characteristics were not various.

국가 사이버보안 전략 수립과 개선을 위한 참조 모델 개발 (Developing Reference Model for National Cybersecurity Strategy Establishment and Improvement)

  • 윤재석
    • 융합보안논문지
    • /
    • 제16권4호
    • /
    • pp.53-61
    • /
    • 2016
  • 많은 국가들은 사이버위협으로 인한 피해를 사전에 예방하고, 사고 발생 시 그 피해를 최소화하기 위해 국가차원의 사이버보안 전략을 수립하여 이행하고 있다. 그러나 국가 사이버보안 전략은 해당 국가가 처한 환경과 필요에 따라 그 수준과 범위에 있어 상당한 편차를 보이고 있다. 어느 한 곳의 취약점은 전 세계적인 문제로 이어질 수 있다는 점에서 국가 사이버보안 전략 수립을 지원하고 개선하기 위해 국제기구를 비롯한 관련 기구, 기관에서 다양한 지침서가 개발되었다. 본 논문에서는 국가 사이버보안 전략 수립을 위해 발표된 각종 지침서를 분석하고, 주요 공통요소를 도출한 참조 모델을 제시하였다. 아울러 이를 우리나라 정책과 비교하여 미흡한 부분에 대한 보완대책을 제안하였다.

Performance Analysis of Real-Time Kinematic GPS Positioning using Continuous Operating Reference Station

  • Lee In-Su;Lee Jae-One;An Sang-Jun
    • Spatial Information Research
    • /
    • 제12권4호
    • /
    • pp.371-382
    • /
    • 2004
  • 상시관측소는 GPS 측량에서 높은 정확도를 제공하며, GPS 사용자가 두 대의 수신기를 사용해야하는 필요를 제거함으로써 GPS 측위를 향상시킨다. 이전에는, 사용자에게 상시관측소로부터 제공된 자료를 후처리함으로써 수행되어졌다. 그러나 RTK-GPS 측량을 이용한 실시간 처리로 향상될 때 상시관측소의 능률은 최대가 될 것이며, 그 이유는 사용자가 기준점을 이용하지 않고서도 실시간으로 cm급의 정확도를 획득할 수 있기 때문이다. 본 연구에서는 인터넷을 통해 RINEX 형태로 제공되는 GPS 상시관측소 자료와 기존의 삼각점을 이용해 관측망을 형성하고 임의점의 좌표를 추출하였다. 또한, 기준점으로써 추출된 임의점을 이용해 RTK GPS를 수행하였다.

  • PDF

Bioavailability Evaluation of Two Ceftriaxone Formulations Using Two Way Crossover Design in Voluteers

  • Kwon, Kwang-Il;Bok, Soo-Jin;Kim, Moo-Heon;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • 제18권4호
    • /
    • pp.237-242
    • /
    • 1995
  • For the vioequivalence study of two ceftriaxone injection formulations ($Rocephin{\circledR}$ ; Roche, and Triaxone ; Hanmi0, the HPLC analytical method for the analysis of ceftriaxone in plasma was used. Fourteen healthy volunteers completed the study and each subject were IM in jected signle doses (1 g) of the test and the reference formulations in a two-way crossover design with an one week drug free interval between doses. Following each administration, plasma concentrations of ceftrixone were monitored over a period of 24 h. Bioequivalence parameters $AUC_{24th}, {\;}T_{max}, {\;}C_{max}$ and MRT determined from the data obtained for the two formulations were examined by analyses of variance (ANOVA) and other criteria and tests for bioequivalence. Results of ANOVA and confidence limits of test/reference ratios of $AUC_{24th}, {\;}T_{max}, {\;}C_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\pm}20%$) except for $T_{max}$ The mean of $T_{max}$ showed only 6. 9% difference from the reference but the detection limit was 22.5% which is slightly over the 20% criteria. No pharmacokinetic parameters including Ka, Kel, Vd and Cl indicated significant difference in between the two fomulations. It was concluded that the data yielded fro the two cefriaxone formulations demonstrated that they were bioequivalent.

  • PDF

기준표적상의 미세구조가 초음파 후방산란에 미치는 영향 (Influence of Microstructure on Reference Target on Ultrasonic Backscattering)

  • 김호철;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.38-44
    • /
    • 2010
  • This paper is based on our comments and proposed amendments to the documents, Annex A, Phantom for determining Maximum Depth of Penetration, and Annex B, Local Dynamic Range Using Acoustical Test Objects 87/400/CDV. IEC 61391-2 Ed. 1.0 200X, prepared by IEC technical Committee 87; Ultrasonics. The documents are concerned with the influence of microstructure of reference target material on the ultrasonic backscattering. Previous works on the attenuation due to backreflection and backscattering of reference target materials are reviewed. The drawback to the use of ungraded stainless steel and metallic materials without microstructural data such as, crystal structure, basic acoustic data of sound velocity and attenuation, grain size, roughness and elastic constants has been discussed. The analysis suggested that the insightful conclusion can be made by differentiating the influence arising from target size and microstructure on the backscattering measurements. The microstructural parameters are associated with physical, geometrical, acoustical and mechanical origins of variation with frequency. Further clarification of such a diverse source mechanisms for ultrasonic backscattering would make the target material and its application for medical diagnosis and therapy simpler and more reliable.

Evaluation of clinical usefulness of reference interval of some selected hematological parameters in canine blood

  • Pak, Son-Il;Han, Ho-Jae
    • 대한수의학회지
    • /
    • 제44권4호
    • /
    • pp.649-653
    • /
    • 2004
  • To estimate the source of variance components for some hematological parameters and assess the utility of the conventional population-based reference interval, this study computed index of individuality for blood samples, which were from 13 dogs drawn once weekly for 4 consecutive weeks. Results were subjected to nested analysis of variance. For all parameters measured between-dog variations were greater than within-dog variation. Except for the parameters RBC and MCHC the index of individuality was <1.4. The low reliability coefficient and high index of individuality of ${\leq}0.8$ were found for the majority of hematological parameters. In practical term, the present study indicated that use of hemogram profiles alone in the evaluating clinical state of a single patient should be avoided because of their physiological or natural random variations, and that comparing a single measurement on the blood analytes from an individual dog to the conventional population-based reference range may be too insensitive to detect any significant changes in the blood components of that particular dog. A single measurement may not characterize an individual's average concentration of the parameters even shortterm period.

참고봉사의 이념과 기준설정을 위한 고찰 -미국에서의 이론과 전개과정을 중심으로- (On the Ideology and the Standard of Reference Service)

  • 박준식
    • 한국문헌정보학회지
    • /
    • 제8권
    • /
    • pp.103-128
    • /
    • 1981
  • This study has two aims. one is to devide the ideology of reference service into three groups such as conservative, moderative, and progressive theories, and then investigate the validity of each theory as well as any problems to be suggested. The other is to establish appropriate standards of reference service according to the types of libraries and users, based on the analysis of such theories. Each theory has its own merits and demerits. Accordingly, it seems to be difficult to apply uniformly and theory into users who have different types of question and educational levels. And also it is difficult to apply into various libraries which have different aims of establishment, characteristics, and the users of each library. Consequently, it is suggested to set up a norm of reference service according to the types of libraries and users respectively. The conservative theory is applicable to small and medium sized public libraries, school libraries, and college and university libraries of which the users are mainly students and citizens. The progressive theory is desirable for special and academic libraries as well as large public libraries where the users are mainly specialists. and scholars.

  • PDF

분자량측정을 위한 Reference Plasmid 보유균주의 이용 (The Use of the Strain Containing Multiple Plasmids as Size Reference Plasmids)

  • 방성혁;이유철;설성용;조동택
    • 대한미생물학회지
    • /
    • 제22권3호
    • /
    • pp.267-273
    • /
    • 1987
  • In the analysis of plasmid profile obtained by agarose gel electrophoresis, the strain harvoring multiple reference plasmids of known molecular weight were needed to estimate the size of unknown molecular weight plasmids. Six strains of E. coli isolated from clinical specimens carried multiple plasmids and these strains could be available as a reference plasmids harvoring strain. These E. coli strains showed 4 to 9 plasmids of various size ranging 2.5 to 94.3 megadalton (Mdal). The correlation coefficients of linear regression between the relative mobility and molecular weight were 0.99966 to 1.00000. Among them, E. coli KE327 from throat which contained 7 plasm ids as follows: 79 Mdal, 46 Mdal, 33 Mdal(pKY3027 C), 4.9Mdal, 3.8Mdal(pKY3027 E), 3.5Mdal, and 2.7 Mdal. Relative amount of the pKY3027 C was the smallest(7.09%) and that of the pKY3027 E was the largest (24.24%) among the plasmid fractions of E. coli KE327.

  • PDF