• Title/Summary/Keyword: Reference Analysis

Search Result 6,558, Processing Time 0.033 seconds

Engineering J-Integral Estimation for Internal Axial Surface Cracks in Cylinders (II) -Optimised Reference Stress Based Estimation- (실린더에 존재하는 축방향 표면균열에 대한 공학적 J-적분식 (II) - 최적참조응력에 기초한 방법-)

  • Kim, Jin-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2442-2449
    • /
    • 2002
  • This paper provides an reference stress based J estimation equation fur cylinders with finite internal axial surface cracks under internal pressure. In part 1, the J estimation equation based on deformation plasticity using Ramberg-Osgood (R-0) materials is proposed. In this paper, the developed CE/EPRI -type solutions ale then re-formulated based on the reference stress concept. Such a re-formulation provides a simpler equation for J. estimation are then further extended to combined internal pressure and bending. The proposed reference stress based J estimation equation is compared with elastic-plastic 3-D FE results using actual stress-strain data for a Type 304 stainless steel. Good agreement between the FE results and the proposed reference stress based J estimations provides confidence in the use of the proposed method to elastic -plastic fracture mechanics of pressurised piping.

Prediction of an Essential Gene with Potential Drug Target Property in Streptococcus suis Using Comparative Genomics

  • Zaman, Aubhishek
    • Interdisciplinary Bio Central
    • /
    • v.4 no.4
    • /
    • pp.11.1-11.8
    • /
    • 2012
  • Genes that are indispensable for survival are referred to as essential gene. Due to the momentous significance of these genes for cellular activity they can be selected potentially as drug targets. Here in this study, an essential gene for Streptococcus suis was predicted using coherent statistical analysis and powerful genome comparison computational method. At first the whole genome protein scatter plot was generated and subsequently, on the basis of statistical significance, a reference genome was chosen. The parameters set forth for selecting the reference genome was that the genome of the query (Streptococcus suis) and subject must fall in the same genus and yet they must vary to a good degree. Streptococcus pneumoniae was found to be suitable as the reference genome. A whole genome comparison was performed for the reference (Streptococcus pneumoniae) and the query genome (Streptococcus suis) and 14 conserved proteins from them were subjected to a screen for potential essential gene property. Among those 14 only one essential gene was found to be with impressive similarity score between reference and query. The essential gene encodes for a type of 'Clp protease'. Clp proteases play major roles in degrading misfolded proteins. Results found here should help formulating a drug against Strptococcus suis which is responsible for mild to severe clinical conditions in human. However, like many other computational studies, the study has to be validated furthermore through in vitro assays for concrete proof.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

Continuing education for reference librarians in academic libraries (대학도서관의 참고사서을 위한 계속교육)

  • 박준식;박은정
    • Journal of Korean Library and Information Science Society
    • /
    • v.25
    • /
    • pp.569-593
    • /
    • 1996
  • The purpose of this study is to synthesize the theoretical systems concerning the necessity, methods, contents, and institutions of the continuing education for academic reference librarians in Korea, and to present a direction after performing a survey research to the librarians and grasping the phenomena on the basis of the system. The necessity, participation, contents, and performing institutions of continuing education were examined in detail, and the correlations among the sub-groups divided by gender, age, academic level of study, career as a librarian were analyzed. Also the direction of continuing education for reference librarians was presented on the basis of the analysis. On the basis of the analyzed contents, the following three methods for an ideal form to the continuing education of the reference librarians were presented in this thesis. 1) It is desirable that the continuing educations are performed at a professionalized institutions such as a library and information science department in a college and an education center for librarians which offers the Certificates of Advanced Study(CAS) as a librarian. 2) It is necessary to develop the various types of educational program in which a working reference librarian may take more chances to study during vacation, weekends, or in the evening time. 3) It is necessary to develop the proper educational contents that reference librarians want, and to educate the librarians in order for them to keep pace with the change of times.

  • PDF

Reference Electrode at Molten Salt: A Comparative Analysis of Electroceramic Membranes

  • Yoon, Seokjoo;Kang, Dokyu;Sohn, Sungjune;Park, Jaeyeong;Lee, Minho;Choi, Sungyeol
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.143-155
    • /
    • 2020
  • A reference electrode is important for controlling electrochemical reactions. Evaluating properties such as the reduction potential of the elements is necessary to optimize the electrochemical processes in pyroprocessing, especially in a multicomponent environment. In molten chloride systems, which are widely used in pyroprocessing, a reference electrode is made by enclosing the silver wire and molten salt solution containing silver chloride into the membranes. However, owing to the high temperature of the molten salt, the choice of the membrane for the reference electrode is limited. In this study, three types of electroceramic, mullite, Pyrex, and quartz, were compared as reference electrode membranes. They are widely used in molten salt electrochemical processes. The potential measurements between the two reference electrode systems showed that the mullite membrane has potential deviations of approximately 50 mV or less at temperatures higher than 650℃, Pyrex at temperatures lower than 500℃, and quartz at temperatures higher than 800℃. Cyclic voltammograms with different membranes showed a significant potential shift when different membranes were utilized. This research demonstrated the uncertainties of potential measurement by a single membrane and the potential shift that occurs because of the use of different membranes.

Engineering J-Integral Estimation for Semi-Elliptical Surface Cracked Plates in Tension (인장하중이 작용하는 평판에 존재하는 반타원 표면균열의 J-적분 계산식)

  • Sim, Do-Jun;Kim, Yun-Jae;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1777-1784
    • /
    • 2001
  • This paper provides d simplified engineering J estimation method fur semi-e1liptical surface cracked plates in tension, based on the reference stress approach. Note that the essential element of the reference stress approach is the plastic limit lead in the definition of the reference stress. However, for surface cracks, the definition of the limit load is ambiguous ("local" or "global"limit lead), and thus the most relevant limit load (and thus reference stress) for the J estimation should be determined. In the present work, such limit load solution is found by comparing reference stress bated J results with those from extensive 3-D finite element analyses. Validation of the proposed equation against FF J results based on tactual experimental tensile data of a 304 stainless steel shows excellent agreements not only far the J values at the deepest point but also for those at an arbitrary paint along the crack front, including at the surface point. Thus the present results provide a good engineering tool for elastic-plastic fracture analyses of surface cracked plates in tension.

Service Coverage Analysis on Land-based DGPS Station due to Output Power Enhancement (송신출력 증강에 따른 내륙 DGPS 기준국의 서비스 영역 분석)

  • Baek, Hwa-Jong;Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1350-1357
    • /
    • 2012
  • Korean NDGPS, which consists of the ocean-based reference station of 11 site and the land-based reference station of 6 sites, are operating. The land-based reference stations provide the output power of 500W, the service shadow regions are occurred due to mountains and nation topography. In this paper, the service coverages of land-based reference stations are analyzed in the viewpoint of output power enhancements of land-based reference stations within 1KW. Also, we suggest virtual land DGPS reference stations 2 sites to resolve the service shadow regions.

Reference Points Selection for Interpolation in Digital Elevation Model (수치표고모델의 보간기준점 선정에 관한 연구)

  • 최병길;김욱남;진세일
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 2003
  • The method that selects reference points for interpolation is very important in Digital Elevation Model. However, there is no definition of an accurate standard until now, so users select the reference points for interpolation at their option. This paper aims to study on the accurate selection of the reference points for interpolation of DEM. This paper analyzed the method using the number of points and the reference points selection method by using the average distance calculated, from irregular points. Based on the analysis of the results, it shows that the Kriging method applying of the average distance is more efficient in construction of DEM.

Site Calibration for the Wind Turbine Performance Evaluation (풍력발전기 성능실증을 위한 단지교정 방법)

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.49-57
    • /
    • 2002
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the Taekwanryung test site are presented using a one-month wind data from a reference meteorological mast and a temporal mast installed at the site of wind turbine. From this analysis, it turns out that the current location of the reference meteorological mast is wrongly determined, and the self-developed codes for the site calibration are working properly. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

  • PDF

Automatic P300 Detection using ICA with Reference (Reference를 갖는 ICA를 이용한 자동적 P300 검출)

  • Park, Heeyoul;Park, Seungjin
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.193-195
    • /
    • 2003
  • The analysis of EEG data is an important task in the domain of Brain Computer Interface (BCI). In general, this task is extremely difficult because EEG data is very noisy and contains many artifacts and consists of mixtures of several brain waves. The P300 component of the evoked potential is a relatively evident signal which has a large positive wave that occurs around 300 msec after a task-relevant stimulus. Thus automatic detection of P300 is useful in BCI. To this end, in this paper we employ a method of reference-based independent component analysis (ICA) which overcomes the ordering ambiguity in the conventional ICA. We show here. that ICA incorporating with prior knowledge is useful in the task of automatic P300 detection.

  • PDF