• 제목/요약/키워드: Reduction of vibration level

검색결과 412건 처리시간 0.028초

배전용변압기의 소응저감을 위한 진동주파수의 스펙트럼분석 (Analysis of Vibration-Frequency Spectrum of Distribution Transformer for Noise Reduction)

  • 이도훈;김재철;송승엽;이현구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.346-348
    • /
    • 2002
  • This paper analyze spectrum of vibration-frequencies to reduce noise level of distribution transformer. Using loading back method on same condition of a real load to grasp the effect of core and winding which are caused by the transformer vibration. we were measured the vibration-frequency by varing applied voltage and load current of a transformer. The major cause of a transformer vibration is occured by the harmonic effects, and was identified that the vibration is less influenced by the coil. As the result of this paper, comparing the transformer with some isolated material with the general transformer the transformer with some isolated material could reduce spectral amplitude of vibration-frequencies.

  • PDF

진동 인텐시티 해석을 통한 원유운반선의 거주구 횡방향 진동 저감 연구 (Transverse vibration reduction at navigation bridge deck of the shuttle tanker using structural intensity analysis)

  • 김기선;김희원;주원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2012
  • Structural intensity has been mainly utilized to identify vibration energy flow in a vessel. In this paper, the structural intensity of a shuttle tanker subjected to H-moment of the main engine was calculated using a finite element model. From the analysis, it was found that the top-bracing elements, which support the main engine onto the hull structure to prevent the excessive transverse vibration of the main engine, play the role of the dominant path and sink for vibration energy flow from the main engine. Therefore, the structural intensity was controlled by the modification of stiffness and damping characteristics of the top-bracing elements. As a result, it is observed that the transverse vibration level at the center of navigation bridge deck decreased after the control of structural intensity.

  • PDF

소형 굴삭기 방사소음 개선 사례 (A Case Study for the reduction of Mini Excavator Radiated Noise)

  • 박재성;박수동;조희;김주호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.488-489
    • /
    • 2014
  • This paper is a case study for the reduction of excavator Radiated noise. The main purpose of the study is to reduction noise for the cooling fan and hydraulic line which is main noise source of the excavator. Recent, noise regulations for the construction equipment is becoming stricter. Compare to past excavator drivers requirements for noise level demanding are becoming more and more. Therefore, this progress is an important role in determining the quality of the excavator.

  • PDF

진동 특성을 고려한 승용차용 사이드 미러의 설계 (Design of a Side Mirror for Passenger Vehicle Based on Vibration Characteristics)

  • 손상욱;손권
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.703-713
    • /
    • 1999
  • A side mirror is an important safety tool with which the driver can observe objects out of sight. This paper presents an organized design technology for the side mirror of improved vibration characteristics. Resonance response to forced vibration is critical to observability through the mirror to be designed. This study aims at the reduction of vibration level by the modification of mirror structures and consequent effects are predicted by computer simulations. We used a three-dimensional solid modeling and the modal and frequency analysis ; Pro/Engineer is used as a solid modeler; Pro/Mechanica for vibration analysis. The simulation results are compared with those obtained in experiemnts to check the validity by the three-dimensional modeling. The design technique of side mirror has been established and found to be effective in vibration analysis of redesigned parts.

  • PDF

소음지도에 나타난 환경기준 초과소음지역에 대한 소음저감대책 수립에 관한 연구 (A Study on the Counterplan of Noise Reduction for the Noise Excess Area of Environment Standard Appeared in Noise Map)

  • 임재석;이병찬;고준희;박수진;장서일;송귀석;김재선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1048-1052
    • /
    • 2007
  • Using road traffic noise, noise map for CheongJu city was drawn. Noise level is estimated and many regions of the city are classified noise excess area compared with environment standard value. Counterplan for the noise excess areas is presented in this study. Noise reduction methods are given in many ways, for example soundproofing walls, low noise pavement, low noise arrangement of buildings and low noise windows.

  • PDF

다구찌 법을 이용한 에어컨용 회전압축기 공명기에 관한 실험적 연구 (Experimental Analysis Using Taguchi Method on the Resonator in the Rotary Compressor for Air Conditioner)

  • 이병찬;김진동
    • 한국소음진동공학회논문집
    • /
    • 제14권1호
    • /
    • pp.3-9
    • /
    • 2004
  • This paper introduces the experimental analysis of the resonator in the rolling piston type compressor for air conditioner. The resonator located between cylinder and hearing is a major factor in the noise reduction of the rotary compressor. Several shapes for the resonator which can be built in the space limitations are derived. Then optimal resonator type for the noise reduction is determined by noise tests. 6 design parameters of the type are found and optimal level for each design factor is deduced from Taguchi method.

청소기의 공력소음 특성 파악 및 저소음화에 관한 연구 (A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner)

  • 전완호;백승조;김창준
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.460-466
    • /
    • 2003
  • The aeroacoustic characteristics and noise reduction method of a centrifugal fan for a bagless vacuum cleaner were studied. The major noise source of vacuum cleaner is the centrifugal fan. The impeller of the fan rotates over 30000 rpm and generates very high-level piercing noise. It was found that the dominant noise source of the fan is generated from the aerodynamic interaction between the highly rotating impeller and stationary diffuser. In order to reduce the high tonal sound generated from the aerodynamic interaction between the impeller and diffuser, tapered impeller was carefully designed and tested. The trailing edge of the tapered impeller was inclined and this reduces the flow interactions between the rotating impeller and the stationary diffuser because of some phase shift. The static efficiency of the new impeller is slightly lower than the conventional one. The overall SPL is reduced about 3.6 dBA. The SPL of blade passing frequency(BPF) is reduced about 6 dBA and the $2^{nd}$ BPF is reduced about 20 dBA. The vacuum cleaner with the tapered impeller has lower noise level than that of the previous impeller and the strong tonal sound was dramatically reduced.

초고밀도 디스크 드라이브를 위한 반 진공 작동 환경에서 서보 트랙 기록 방법에 의한 RRO 저감에 대한 연구 (Repeatable Run-out Reduction by Servo Track Writing in Semi-vacuum Condition for Ultra-high TPI Disk Drive)

  • 한윤식;강심우
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1176-1181
    • /
    • 2004
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal(PES) is becoming smaller and smaller. In order to achieve the high TPI(track per inch) disk drive, it is necessary to improve the writing accuracy during the servo track writing(STW) Process through the reduction of track mis-registration sources. Among the main contributors of the non-repeatable runout(NRRO) PES, the disk vibration and the head-stack assembly vibration is considered to be one of the most significant factors. Also the most contributors of repeatable runout(RRO) come from the contributors of NRRO which is written-in at the time of STW process. In this paper, the effect of NRRO on servo written-in RRO is Investigated by experimentally, and the experimental result shows that the written-in RRO can be effectively reduced through a STW process under low dense medium condition such as semi-vacuum.

하나로 침니내부지지대의 내진해석 및 진동시험 (Seismic Analysis and Vibration Test of HANARO In-Chimney Bracket)

  • 류정수;윤두병
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.481-488
    • /
    • 2001
  • The HANARO in-chimney bracket was proposed as a structure which supports the guide tubes of irradiation facilities at the irradiation sites of CT, IR and OR4/5 in HANARO core for the reduction of flow-induced vibration and seismic response of the irradiation facilities. For the evaluation of the structural integrity of the in-chimney bracket, its finite element model is developed. The seismic response analysis was performed for the in-chimney bracket and related reactor structures, under the response spectrum of OBE and SSE. The analysis results show that stress values of the in-chimney bracket and reactor structures for the seismic loads are within the ASME code limits. It is also confirmed that its fatigue usage factor is much less than 1.0. For the verification of the implementation effects of the in-chimney bracket, the vibration level of the guide tube of the instrumented fuel assembly, which is subjected to fluid-induced vibration, was measured and analyzed. The vibration analysis results demonstrate that the vibration level of the instrumented fuel assembly has been remarkably reduced after installing the in-chimney bracket. Therefore, when the in-chimney bracket is installed at the reactor chimney, any damage on the structural integrity is not expected.

  • PDF

수치해석을 이용한 함정용 장비 받침대의 기계적 임피던스 및 전달 진동 분석 (Numerical Analysis of the Mechanical Impedance and Transmitted Vibration of the Foundation for the Equipment in a Naval Vessel)

  • 한형석;손윤준
    • 한국소음진동공학회논문집
    • /
    • 제19권5호
    • /
    • pp.462-467
    • /
    • 2009
  • Reduction of the structure-borne noise of the naval vessel is very important in order to reduce the underwater radiated noise of it. One of the important factors to reduce the structure-borne noise of the installed machine in a ship is the design of the foundation having sufficiently high mechanical impedance. In this paper, the mechanical impedance of the foundation for the fan-coil unit in a naval vessel is evaluated numerically according to variation of the thickness of the foundation. And also, the forced vibration analysis is conducted considering the dynamic property of the anti-vibration mount. Through the analysis results, it can be known that the dynamic property of the anti-vibration mount should be considered when the minimum level of the mechanical impedance of the foundation is set.