• 제목/요약/키워드: Reduction of noise & vibration

검색결과 1,562건 처리시간 0.029초

대형급수펌프 토출배관계에 발생하는 규칙적인 이상진동 및 소음 특성 규명 (Vibration and Noise Reduction of Pump And Pipe System)

  • 배춘희;조철환;양경현;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1065-1069
    • /
    • 2003
  • In this paper, Firstly, it is shown that the high vibration and noise source of piping and pump system is the acostic resonance. Secondly, in order to decrese the high vibration and noise of piping and pump system, the acostic mode of piping have been changed and its effectiveness is investigated as applied it at piping system practically.

  • PDF

설계파라미터 변경에 의한 고속버스용 엔진 냉각 팬의 저소음화 연구 (A Study on the Noise Reduction of the Engine Cooing Fan of an Express Bus by Change of Design Parameters)

  • Jae-Eung OH;You-Yub LEE;Hyun-Jin Sim;Mon-Kab Joe
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.333.1-333
    • /
    • 2002
  • This paper suggests the noise reduction method of the engine cooling fan. It was estimated the fannoise contribution at the engine room and identified the noise source at the rotating fan by sound intensity method, first. And it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF and its harmonics and the line spectrum at the broad band by the noise generation mechanisms. In this paper it is shown that the comparison of the measuted and calculaed noise spectra of fn for the validation of the noise predictiong program. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it was obtained the design parameter values for noise reduction of fan.

  • PDF

발전소 변압기 소음저감 대책의 유효성 (The effectiveness of noise reduction devices for transformer noise control of Power Plants)

  • 김연환;김희수;배용채;이현;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

굴삭기 저소음화 기술개발 (Development of Lower Noise Excavator)

  • 고경은;김영현;주원호;김동해;배종국;심재구;강정원;손득균;김춘오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.156-160
    • /
    • 2005
  • The radiated noise of the excavator is composed of the various noise sources such as the diesel engine, cooling fan and hydraulic system, so the noise reduction for each noise source is required. In this study, the source contribution analysis for these principal noise sources is performed by using the noise source removal method. And to reduce the noise due to each one, the various experiments and analyses are studied. On the basis of these results, the proper reduction countermeasures are derived to develop the excavator satisfied the $2^{nd}$ noise regulation of EU.

  • PDF

BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 진동.소음 저감 (Reduction of Vibration and Noise of BLDC Motors by Realizing Sinusoidal Air-Gap Flux Density Distribution)

  • 김사무엘;정승호;권병일;김홍석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.95-97
    • /
    • 2006
  • Cogging torque is often a principal source of vibration, noise and difficulty of control in BLDC motors. Therefore, this paper will present a design method of magnetization system with sinusoidal air-gap flux density distribution of Nd-Fe-B magnets in ring type for reduction of Vibration and Noise and low manufacturing cost.

  • PDF

건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구 (A Case Study on Noise Impact Assessments and Countermeasures for Emergency Generators of the Data Center Building)

  • 윤대진;최재성;김창열;김한준
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.932-939
    • /
    • 2012
  • Recently, data centers are being established because IT and telecommunication industries are growing. The data centers have to install emergency generators to prevent unexpected shutdown of the electrical power supply. When the data centers are located in the densely populated urban area, the operating noise of the emergency generators can be a cause of people's complaints. In this case, it is necessary to establish effective countermeasure by noise & vibration specialists. To achieve this, noise reduction measure using noise measurement data and 3D noise analysis method have been employed in this study.

현장실험을 통한 바닥충격음 저감공법의 성능평가 및 중량충격음 저감 방안 (A Evaluation Study on Reduction Method of Floor Impact Noise through Field Test and the Effective Method for Heavy Impact Noise)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.451-456
    • /
    • 2004
  • In this study, evaluation was carried out for reduction method of floor impact noise through field test and the effective methods for heavy impact noise were proposed. As a field test, impact noise reduction materials such as EPP, EEPS, EVA, PE and so on, did not satisfied the recommandation value at the condition of 150mm thickness concrete slab. The evaluation results for those materials by 'inverse A curve' showed $53\sim55dB$ at heavy impact noise and $53\sim58dB$ at light impact noise. But, two methods proposed by authors were evaluated $47\sim50dB$ at heavy Impact noise and $54\sim58dB$ at light Impact noise on the similar concrete slab thickness.

  • PDF

건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구 (A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture)

  • 윤대진;최재성;김창열;홍창완;김한준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

고속전철 진동소음해석 및 저감기술개발: G-7과제개요 및 연구방향 (Development of the Vibration & Noise Analysis and Reduction Technology for High Speed Train: G-7 Project Outline and Research Direction)

  • 이우식;박철희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.221-232
    • /
    • 1998
  • This paper introduces the outline of the ongoing G-7 project for the development of vibration and noise analysis and reduction technology for the Korea High Speed Train which will run at 350km/h. Extensively collected materials and data on the vibration and noise characteristics of high speed trains are summarized herein to reduce the research direction.

  • PDF

칩 마운트 시스템의 진동 경감 (Vibration Reduction of Chip-Mount System)

  • 임경화;장헌탁
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.331-337
    • /
    • 2001
  • The purpose of this study is to analyze the principal causes of vibration problem and find out the method of vibration reduction in a chip-mount system. The principal causes are investigated through measurements of vibration spectrum and model parameters. Modal parameters are obtained by using an experimental model test. Based on the model parameters from experiments. a model of finite element method is formulated. The model presents effective redesign of increasing the natural frequencies in order to reduce the vibration of a chip-mount system. Further, through computer simulation for the behavior of head to be main vibration source, the best acceleration pattern of head movement can be verified to achieve effective head-positioning and reduce the vibration due to head movement.

  • PDF