• Title/Summary/Keyword: Reduction of Energy

Search Result 5,085, Processing Time 0.036 seconds

The Sintering Behavior of the Hyperstoichiometric Uranium Dioxide in the Oxidative Atmosphere (약 산화성 분위기 중에서의 과산화성 2산화 우라늄의 소결에 관한 연구)

  • Jang Keu Han;Won Ku Park;Han Su Kim
    • Nuclear Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.197-206
    • /
    • 1983
  • The slightly hyperstoichiometric uranium dioxide, i.e. U $O_{2.005}$ and U $O_{2.01}$ within a range of the requirement for the use of a nuclear fuel, were sintered directly in an atmosphere of $CO_2$/CO mixture without any succeeding reduction process. The kinetics of sintering in the late stage were investigated for various O/U ratios. A sintering diagram, which show the relation of Temperature-Time-Density-Grain size, was established for each O/U ratio. Only by controlling the oxygen partial pressure in the sintering atmosphere, U $O_2$ pellet could be sintered very easily at low temperature 1050$^{\circ}$~120$0^{\circ}C$ with a density above 95% T.D. and average grain size above 7${\mu}{\textrm}{m}$. It was found that the rate of grain growth follows D=(Kt)$^{1}$4/ in the late stage of sintering. And the activation energies for grain growth in the final sintering stage were found to be 75, 64 and 62kca1/mo1 for U $O_{2.005}$, U $O_{2.01}$ and U $O_{2.10}$, respectively. Although no significant differences are obtained between the activation energies for different O/U ratios, the sinterability is enhanced considerably with increasing the oxygen partial pressure in the sintering atmosphere.tmosphere.

  • PDF

Numerical Analysis for Fault Reactivation during Gas Hydrate Production (가스하이드레이트 개발과정에서의 단층 재활성화 해석)

  • Kim, Hyung-Mok;Kim, A-Ram
    • Tunnel and Underground Space
    • /
    • v.26 no.2
    • /
    • pp.59-67
    • /
    • 2016
  • In this paper, we perform a numerical analysis to evaluate the potential of fault reactivation during gas production from hydrate bearing sediments and the moment magnitude of induced seismicity. For the numerical analysis, sequential coupling of TOUGH+Hydrate and FLAC3D was used and the change in effective stress and consequent geomechanical deformation including fault reactivation was simulated by assuming that Mohr-Coulomb shear resistance criterion is valid. From the test production simulation of 30 days, we showed that pore pressure reduction as well as effective stress change hardly induces the fault reactivation in the vicinity of a production well. We also investigated the influence of stress state conditions to a fault reactivation, and showed that normal fault stress regime, where vertical stress is relatively greater than horizontal, may have the largest potential for the reactivation. We tested one simulation that earthquake can be induced during gas production and calculated the moment magnitude of the seismicity. Our calculation presented that all the magnitudes from the calculation were negative values, which indicates that induced earthquakes can be grouped into micro-seismic and as small as hardly perceived by human beings. However, it should be noted that the current simulation was carried out using the highly simplified geometric model and assumptions such that the further simulations for a scheduled test production and commercial scale production considering complex geometric conditions may produce different results.

Preparation and Electrochemical Properties of Pr1-x (Sr, Ca)xCoO3 Cathode Materials for Zinc Air Batteries (아연공기전지용 Pr1-x (Sr, Ca)xCoO3 양극촉매 제조 및 전기화학적 특성)

  • Heo, Sang-Hun;Eom, Seung-Wook;Kim, Hyun-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.342-348
    • /
    • 2009
  • Zn/Air secondary batteries are high energy density type and environment-friendly. Also, they have safer properties than batteries of other type by low manufacturing cost and using the electrolyte solution. But, they have a weak concerning large output discharge. Oxygen evolution reaction(OER) and oxgen reduction reaction(ORR) in aqueous solution make a result of a decrease of cell efficiency and life span. Therefore, to minimize the voltage drop from between OCV and charge/discharge voltage is key point. The problem should be solved through developing catalysts of high efficiency. In this study, we synthesized $Pr_{1-x}(Sr,\;Ca)_x\;CoO_3$ powders by citric method and then measured physical characteristics of each powder by XRD, SEM, TGA etc. We examined its electrochemical properties by the cathodic polarization, anodic polarization and cyclic voltammogram. We achieved results that new catalysts showed better performances than existing $La_{1-x}Sr_xCoO_3$, $La_{1-x}Ca_xCoO_3$, ect. catalysts prepared in our lab.

Outside Temperature Prediction Based on Artificial Neural Network for Estimating the Heating Load in Greenhouse (인공신경망 기반 온실 외부 온도 예측을 통한 난방부하 추정)

  • Kim, Sang Yeob;Park, Kyoung Sub;Ryu, Keun Ho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.4
    • /
    • pp.129-134
    • /
    • 2018
  • Recently, the artificial neural network (ANN) model is a promising technique in the prediction, numerical control, robot control and pattern recognition. We predicted the outside temperature of greenhouse using ANN and utilized the model in greenhouse control. The performance of ANN model was evaluated and compared with multiple regression model(MRM) and support vector machine (SVM) model. The 10-fold cross validation was used as the evaluation method. In order to improve the prediction performance, the data reduction was performed by correlation analysis and new factor were extracted from measured data to improve the reliability of training data. The backpropagation algorithm was used for constructing ANN, multiple regression model was constructed by M5 method. And SVM model was constructed by epsilon-SVM method. As the result showed that the RMSE (Root Mean Squared Error) value of ANN, MRM and SVM were 0.9256, 1.8503 and 7.5521 respectively. In addition, by applying the prediction model to greenhouse heating load calculation, it can increase the income by reducing the energy cost in the greenhouse. The heating load of the experimented greenhouse was 3326.4kcal/h and the fuel consumption was estimated to be 453.8L as the total heating time is $10000^{\circ}C/h$. Therefore, data mining technology of ANN can be applied to various agricultural fields such as precise greenhouse control, cultivation techniques, and harvest prediction, thereby contributing to the development of smart agriculture.

The Effects of ICT on CO2 Emissions Along with Economic Growth, Trade Openness and Financial Development in Korea (ICT가 CO2 배출에 미치는 영향: 경제성장, 무역개방성, 금융발전과의 연관관계하에서 분석)

  • Kim, Suyi
    • Environmental and Resource Economics Review
    • /
    • v.30 no.2
    • /
    • pp.299-323
    • /
    • 2021
  • This study investigated the impact of information and communication technology (ICT), trade openness, financial development, and economic growth on CO2 emissions in Korea from 1990 to 2016. The cointegration relationship of the variables was confirmed by an autoregressive distributed lag (ARDL) bounds test. In the long-run, economic growth was statistically significant factor in the increase in CO2 emissions, while other factors, as well as ICT, did not significant factors in the changes in CO2 emissions. In the long-run, a link between economic growth and CO2 emissions has been confirmed, but other factors, including ICT, have not been able to confirm the link between CO2 emissions in the long-run. Meanwhile, in the short-run, economic growth and ICT increased CO2 emissions, and financial development led to a decrease in CO2 emissions. Trade openness did not have a significant effect on CO2 emissions in the short-run as in the long-run. In particular, ICT did not contribute to the reduction of CO2 emissions in the short-run as well as the long-run. In order to induce CO2 mitigation through ICT, the development and deployment of technology that efficiently save energy by using ICT should be further promoted.

Mat Drying Characteristics of the Wet-thresheds Rough-rice and Effect of Drying Environment on the Cracks Formation (생탈곡(生脱糓)벼의 깔아말림 특성(特性)과 건조조건(乾燥條件)이 동할미(胴割米) 발생(發生)에 미치는 영향(影響))

  • Chun, Jae Kun;Choi, Boo Dol;Lee, Jeong Cheol
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.58-64
    • /
    • 1982
  • The fresh threshed paddy-mat dryings on the various environments were analyzed on their drying characteristics and rice quality resulted. The moisture content of paddy was mainly determined by the accumulated solar energy received, and which was expressed as a simple equation. The drying characteristics revealed to follow a constant rate drying type, and as the depth increased the more typical constant-rate drying pattern was observed. The relationship between the drying rate and bed depth was established with a simple exponential equation. The raking operation during the drying period showed a favorable effect both on the drying rate and the reduction of crack formation. Drying environments such as straw mat, concrete, ground, polyethylene film did not affect significantly the drying rate and rice quality. Considering the drying rate and quality, the optimum bed depth of mat paddy drying was around 6 cm.

  • PDF

Implementation of a Sensor Node with Convolutional Channel Coding Capability (컨벌루션 채널코딩 기능의 센서노드 구현)

  • Jin, Young Suk;Moon, Byung Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.1
    • /
    • pp.13-18
    • /
    • 2014
  • Sensor nodes are used for monitoring and collecting the environmental data via wireless sensor network. The wireless sensor network with various sensor nodes draws attention as a key technology in ubiquitous computing. Sensor nodes has very small memory capacity and limited power resource. Thus, it is essential to have energy efficient strategy for the sensor nodes. Since the sensor nodes are operating on the same frequency bands with ISM frequency bands, the interference by the devices operating on the ISM band degrades the quality of communication integrity. In this paper, the convolutional code is proposed instead of ARQ for the error control for the sensor network. The proposed convolutional code was implemented and the BER performance is measured. For the fixed transmitting powers of -19.2 dBm and -25dBm, the BER with various communication distances are measured. The packet loss rate and the retransmission rate are calculated from the measured BER. It is shown that the porposed method obtained about 9~12% and 12-19% reduction in retransmission rate for -19.2 dBm and -25 dBm respectively.

A Study on the Power Interconnection in the Northeast Asian Region (동북아 에너지협력을 위한 전력계통 연구 : 러시아와의 전력계통 연계를 중심으로)

  • Kim, Hyun Jae;Roh, Dong Seok;Jo, Sung Han
    • Environmental and Resource Economics Review
    • /
    • v.17 no.3
    • /
    • pp.167-199
    • /
    • 2008
  • There are many successful cases in power interconnection among European and South American countries. However, that is not the case in Northeast Asian countries. Even though there will be a considerable benefit in power interconnection in Northeast Asian countries, there will be some difficulties due to various interest relationship and constraints among countries in Northeast Asia. GTMax(Generation and Transmission Maximization) Program is a very useful tool to analyze competitive electricity market and power interconnection developed by Argonne National Laboratory under the Department of Energy in the USA. This study tried to verify applicability and usefulness by GTMax model to domestic electric power system and power transfer from Russia Far East by power interconnection. When the power by importing from Russia is 2,000MW(around 2% of domestic installed capacity in 2017), there is no impact on domestic electricity market because of small power transfer. The power by importing should be large enough for achieving greater cost reduction by power interconnection. Besides, it would be better to supply power to Kyung-In region directly in reducing overall cost when the power by importing from Russia are sold at low price. In the case of interconnecting Young-Dong region, if it is not possible to upgrade transmission line with power transfer capabilities between Young-Dong and Kyung-In region, then the power by importing from Russia can replace the power produced in Jung-Bu region and the relative benefit of importing power can be reduced.

  • PDF

Color Media Instructions for Embedded Parallel Processors (임베디드 병렬 프로세서를 위한 칼라미디어 명령어 구현)

  • Kim, Cheol-Hong;Kim, Jong-Myon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.7
    • /
    • pp.305-317
    • /
    • 2008
  • As a mobile computing environment is rapidly changing, increasing user demand for multimedia-over-wireless capabilities on embedded processors places constraints on performance, power, and sire. In this regard, this paper proposes color media instructions (CMI) for single instruction, multiple data (SIMD) parallel processors to meet the computational requirements and cost goals. While existing multimedia extensions store and process 48-bit pixels in a 32-bit register, CMI, which considers that color components are perceptually less significant, supports parallel operations on two-packed compressed 16-bit YCbCr (6 bit Y and 5 bits Cb, Cr) data in a 32-bit datapath processor. This provides greater concurrency and efficiency for YCbCr data processing. Moreover, the ability to reduce data format size reduces system cost. The reduction in data bandwidth also simplifies system design. Experimental results on a representative SIMD parallel processor architecture show that CMI achieves an average speedup of 6.3x over the baseline SIMD parallel processor performance. This is in contrast to MMX (a representative Intel's multimedia extensions), which achieves an average speedup of only 3.7x over the same baseline SIMD architecture. CMI also outperforms MMX in both area efficiency (a 52% increase versus a 13% increase) and energy efficiency (a 50% increase versus an 11% increase). CMI improves the performance and efficiency with a mere 3% increase in the system area and a 5% increase in the system power, while MMX requires a 14% increase in the system area and a 16% increase in the system power.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF