• Title/Summary/Keyword: Reduction of Energy

Search Result 5,085, Processing Time 0.036 seconds

Characterizations of Pt-SPE Electrocatalysts Prepared by an Impregnation-Reduction Method for Water Electrolysis (함침-환원법으로 제조된 수전해용 Pt-SPE 전극촉매의 특성)

  • Jang, Doo-Young;Jang, In-Young;Kweon, Oh-Hwan;Kim, Kyoung-Eon;Hwang, Gab-Jin;Kang, An-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.440-447
    • /
    • 2006
  • Solid polymer electrolyte(SPE) membrane with electrodes embedded on both faces offer unique possibilities for the electrochemical cells like water electrolyzer with fuel cell. The Nafion 117 membrane was used as the SPE, and $Pt(NH_3)_4Cl_2$ and $NaBH_4$ as the electrocatalysts and reducing agent, respectively. The 'impregnation-reduction(I-R) method' has been investigated as a tool for the preparation of electrocatalysts for water electrolyzer by varying the concentration of reducing agent and reduction time at fixed concentration of platinum salt, 5 mmol/L. Pt-SPE electrocatalysts prepared by non-equilibrium I-R method showed the lowest cell voltage of 2.17 V at reduction time, 90 min and with concentration of reducing agent 0.8 mol/L and the cell voltage with those by equilibrium I-R method was 2.42 V at reduction time, 60 min and with concentration of reducing agent 0.8 mol/L. The cell voltage were obtained at a current density $1\;A/cm^2$ and $80^{\circ}C$. In water electrolysis, hydrogen production efficiency by Pt-SPE electrocatalyst is 68.2% in case of non-equilibrium I-R method and 61.2% at equilibrium I-R method.

An Analysis of Energy Reduction Effects in Housing According to Green Roof (옥상녹화에 따른 공동주택 에너지 저감효과 분석 연구)

  • Kim, Ji-Hyeon;Son, Hyeong-Min;Kwon, Hyuck-Sam;Kim, Jong-Gon;Lee, Bum-Sik
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.299-305
    • /
    • 2016
  • This study aims to provide basic materials for expanding application of green roof afforestation by analyzing structures' energy consumption reduction effects according to green roof afforestation as a planning means to cope with climate change. As the subjects, recently completed apartment buildings and service facilities of apartment houses where green roof afforestation was applied were selected. green roof afforestation of Extensive Green Roof(soil depth: 20cm) and Semi-Intensive Green Roof(soil depth: 40cm) in construction types was applied and design builders were utilized in order to compare energy reduction amount according to the application of green roof afforestation. According to the analysis result, all the buildings had energy reduction effect when green roof afforestation was applied.

Economic Effects of the Post-2020 Climate Change Mitigation Commitments: From the Generation Industry's Perspective (Post-2020 신기후체제의 발전부문 대응에 따른 경제적 파급효과 분석)

  • Yun, Taesik;Lee, Bongyong;Noh, Jaeyup
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.136-148
    • /
    • 2016
  • We analyze economic effects of GHG reduction measures of the generation industry to meet 2030 GHG reduction target using the scenario based approach. We estimate the GHG emission of the Korean power industry in 2030 based on both the $7^{th}$ Electricity Supply & Demand Plan and the GHG emission coefficients issued by IAEA. We set up three scenarios for reduction measures by replacing the coal fired plants with nuclear power, renewable energy and carbon capture and storage. Once and for all, the nuclear power scenario dominates the other energy technologies in terms of GHG reduction quantities and economic effects.

Energy Efficiency Improvements in the Korean Industry (한국 제조업의 에너지효율 향상평가)

  • Park, Hi Chun
    • Environmental and Resource Economics Review
    • /
    • v.10 no.2
    • /
    • pp.135-159
    • /
    • 2001
  • This study analyses the energy consumption increase by using a physical production index (PPI) based decomposition method. The energy efficiency of the Korean industry deteriorated to a large extent in the 1992 to 1997 period. This outcome, however, does not contradict the result of a previous study that the physical energy intensities (measured by energy use per production unit) decreased in four Korean energy intensive industries such as steel, cement, petrochemical and pulp and paper in the same period. Although the physical energy intensities in four industries considered decreased significantly, the energy efficiency of the Korean industry deteriorated because the increase in the value-added production was smaller than that in the physical production except for the steel industry. This outcome suggests that the reduction in the physical energy intensity alone will not result in reducing the economic energy intensity, thereby reducing the increase in the energy consumption of the Korean industry. Therefore, it necessitates to restructure the Korean industry towards a higher value-added production and to strengthen energy efficiency improvement efforts in the Korean industry. As the overinvestment in the energy intensive industries caused a deep price fall of Korean products and a reduction of the value added of the Korean industry and with it an increase in the economic energy intensity, a decrease in this intensity will highly depend on reducing the overcapacity in the energy intensive industries which was partly responsible for the currency and economic crisis of 1997.

  • PDF

Oxygen Reduction Reaction Evaluation of Synthesized 20% Pt/C with Beat Treatment by Chemical Reduction Method (화학환원법(化學還元法)을 이용(利用)해 제조(製造)한 20% Pt/C 캐소드 촉매(觸媒)의 열처리(熱處理)에 따른 산소환원반응(酸素還元反應) 평가(評價))

  • Kim, Jin-Hwan;Kang, Suk-Min;Thube, Dilip.R.;Ryu, Ho-Jin
    • Resources Recycling
    • /
    • v.18 no.5
    • /
    • pp.12-18
    • /
    • 2009
  • The 20% Pt/C catalysts were synthesized using the chemical reduction method for polymer electrolyte fuel cell cathode and were heat-treated in the temperature range from 300 to $600^{\circ}C$. The oxygen reduction reaction of the catalysts was evaluated using the electrochemical measurement. The oxygen reduction reaction of the heat-treated Pt/C at $300^{\circ}C$ had high catalytic activity and the oxygen reduction reaction current of that was 2 times than that of non-heat treatment catalyst. It is considered that the change of the crystallinity and particle size by heat treatment could increase the catalytic activity.

A Study on Heating Energy Monitoring of a Rural Detached House Applying Passive House Design Components (패시브 하우스 디자인 요소를 적용한 농촌지역 단독주거건물의 난방에너지 모니터링 연구)

  • Cho, Kyung-Min;Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Recently, the field of construction is putting a variety of effort into reducing CO2, since global warming is being accelerated due to climate changes and the increase of greenhouse gas. For reduction of CO2 in the field of construction, it is required to make plans to cut down heating energy of buildings and especially, it is urgently needed to cut down energy of residential buildings in rural area where occupies the majority of consumption of petroleum-based energy sources. Therefore, this research compared and analyzed the actual energy consumption, by evaluating energy performance of a detached house applying passive house design components for reduction of energy. As the result, energy consumption showed remarkable differences, according to the operation of a heat recovery ventilation unit which is one of passive house design components, and building energy consumption displayed remarkable differences, too, depending on the difference of airtightness performance during building energy simulation conducted in process of design. Based on these results, the importance of airtightness performance of passive house was verified. The result of the actual measurement of energy consumption demonstrated that LNG was most economical amongst several heat resources yielded, on the basis of LPG source energy consumption measured within a certain period of time, and it was followed by kerosene. LPG was analyzed to have a low economic efficiency, when used for heating.

An Evaluation of Net-zero Contribution Regarding Hydrogen Energy Conversion in Urban Building and Transport Sector (도시의 건물 및 수송 부문에서의 수소에너지 전환에 따른 탄소중립 기여도 평가)

  • SO JEONG JANG;RAE SANG PARK;YOUNG HOON CHOI;YONG WOO HWANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.100-112
    • /
    • 2023
  • This study evaluated the contribution of carbon neutrality by calculating the carbon reduction amount and reduction intensity targeting the hydrogen pilot city and applying it to the carbon neutral reduction target. In the building sector, the reduction amount for 2030 was 10.8% on average. In addition, by 2050, the contribution to carbon neutrality of plan A was 14.1% on average, and the contribution to carbon neutrality of plan B was 15.1% on average. In the 2030 reduction amount of the transportation sector, the contribution to carbon neutrality was 138.4% on average. In addition, by 2050, the contribution to carbon neutrality in plan A was 82.5% on average, and the contribution to carbon neutrality in plan B was 74.9%. From the above research results, additional carbon reduction is possible when creating a hydrogen city, so it will be used as a basis of city-level carbon neutral model. It will also be used as a basis for technology development and investment promotion for various hydrogen supply methods in the future.

Perspectives on Solar Energy Development in the Age of Climate Change Convention (기후변화협약 시대의 태양에너지 개발 전망)

  • Hong, Wuk-Hee
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.3-18
    • /
    • 1998
  • Since entered into force in 1994, United Nations Framework Convention on Climate Change(UNFCCC) would require all the member nations to adopt national programme for mitigating climate change and industrialized countries to undertake specific commitments of carbon dioxide emission reduction. Considering all the situation, it may be safe to assume that Korea would undertake such commitment early in the next century. Unfortunately, however, we are in the position that is very disadvantageous in preparing national strategies for carbon dioxide reduction mainly due to our rigid energy-intensive economic structure and poor geographic conditions. Solar energy is regarded as most available renewable energy resource in Korea and hence development of solar energy technology would serve as one of most effective alternatives for energy conservation and renewable energy utilization. In this regard, the presenting paper discuss the perspectives on solar energy development in relation to carbon dioxide reduction strategies. Such technologies of solar cell mass production and solar heating were considered to be most advantageous among many solar energy solutions discussed in this paper.

  • PDF

An Evaluation on the Effect of the MSW-RDF Power Generation on the Thermal Efficiency and $CO_2$ Reduction (RDF발전에 의한 열효율향상 및 $CO_2$삭감효과에 대한 평가)

  • Choe, Gap-Seok;Choe, Yeon-Seok;Kim, Seok-Jun;Gwon, Yeong-Bae
    • 연구논문집
    • /
    • s.31
    • /
    • pp.45-51
    • /
    • 2001
  • One of emerging technologies under development in the advanced countries is considered as RDF(Refuse Derived Fuel) power generation, which could meet both the requirement of an alternative energy resource utilization and $CO_2$ reduction. This paper deals with the effect to the thermal effiency and CO2 reduction of RDF firing power generation. The statistical data of domestic MSW generation in last year in small and medium cities for evaluating the merits of the RDF power generation were used. The analysis for RDF power generation compared to the existing incinerator w/o(or w/) power generation shows around 20.6%(10.0%) up in the total thermal efficiency and 57.0%(31.4%) up in the $CO_2$ reduction respectively.

  • PDF

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.