• Title/Summary/Keyword: Reduction of Energy

Search Result 5,085, Processing Time 0.032 seconds

A CO2 Emission Reduction Method through Correlation Analysis of Design Parameters in Buildings (건축물 설계변수의 상관관계 분석을 통한 CO2 배출저감 방안)

  • Lee, Hyun-Woo;Chae, Min-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.100-106
    • /
    • 2011
  • This study proposes a $CO_2$ emission reduction method through correlation analysis of a sample building. First, energy saving factors of heating, cooling, lighting were determined for the correlation analysis and $CO_2$ emission contribution rate of the design parameters have been analyzed. Then optimal combination of each design parameter has been drawn. Heat transfer coefficient of walls and windows, air permeability, windows area ratio, and shading devices were selected as applicable energy saving factors of the sample building. Also computer simulation was conducted using experimental design by Orthogonal Arrays of the statistical method. And the contribution rate was estimated by Analysis of Variance-ANOVA. As a result, the $CO_2$ emission in heating was reduced to 51.9%; in cooling to 16.8%; and in lighting to 2% compared to the existing building. The majority of the reduction was presented by heating energy.

Study on Photocatalytic Cr(VI) Reduction with Metal Deposited Anodized $TiO_2$ Tube (금속담지된 $TiO_2$ 나노튜브를 활용한 Cr(VI)환원의 광화학적 효율 연구)

  • Heo, Ah-Young;Lee, Chang-Ha;Park, Min-Sung;Shim, Eun-Jung;Yoon, Jae-Kyung;Joo, Hyunk-Ku
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.301-306
    • /
    • 2010
  • The present work is performed to photocatalytically reduce Cr(VI) by means of metal deposited anodized $TiO_2$ tubes, which are prepared by anodization of Ti foil followed by metal deposition. Stably immobilized photo-reactive materials are favored in the field of detoxification in a conventional aqueous medium, preventing gradual loss of efficiency and process malfunction due to detachment of the materials. The prepared samples are characterized by SEM, TEM, EDAX, and photocurrent. The metal deposited-$TiO_2$ electrode shows higher efficiency for Cr(VI) reduction (ca. 20%) and higher ability for adsorption (4~5 times) than pure one.

Effects of Temperature, Pressure, Gas Velocity, and Capacity on Reduction Characteristics of Mass Produced Particle in a 0.5 MWth Chemical Looping Combustion System (0.5 MWth 급 케미컬루핑 연소시스템에서 대량생산 산소전달입자의 환원반응 특성에 미치는 온도, 압력, 유속 및 용량의 영향)

  • RYU, HO-JUNG;LEE, DOYEON;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOOSEOB;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.1
    • /
    • pp.53-62
    • /
    • 2021
  • Batch type reduction-oxidation tests were performed to check effects of temperature, pressure, gas velocity, and capacity on reduction characteristics of mass produced particle in a 0.5 MWth chemical looping combustion system. The fuel conversion and the CO2 selectivity increased as the temperature increased and as the gas velocity decreased. However the CO2 selectivity showed the maximum and decreased as the capacity increased because the CO emission increased. The results show that high temperature, low gas velocity and low inert gas concentration are preferable to ensure high reactivity of oxygen carrier in the fuel reactor.

Design and Implementation of Context-Aware-based Emergency Detection System with Energy Reduction for Elderly Housing (고령자 주거환경을 위한 상황인지 기반 에너지 저감형 위급상황 감지 시스템 설계 및 구현)

  • Mah, Sung-Hoon;Bae, Hong-Min;Kim, Byung-Seo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.159-165
    • /
    • 2017
  • As increasing the number of the elderly people, various IT-based home systems for the elderly are actively studied. However, while most systems for the elderly focus on systems detecting emergency cases, systems considering energy reduction in the elderly housing are rarely found. In fact, the systems for the elderly housing consumes rather more electric power for their functions. In this paper, a emergency monitoring system including the functions to reduce energy useage is studied and it is implemented. Though the system, we can achieve both of future-oriented functions for the aged and green society, which are emergency monitoring and energy reduction.

Study on Evaluation Method of Thermal Potential of Unused Energy (미활용에너지의 열 포텐셜 평가 수법에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.493-501
    • /
    • 2006
  • The increase in environmental loads and energy consumptions has resulted in the need of developed new forms of energy for a sustainable use for the society. Recently, the viability of using unused energy has attracted a great deal of attention. From the view point of using unused energy, the most critical problem can be referred to as the distance between the heat source/sink and heat demand area. The water resource in the city water system was used to solve this distance problem with unused energy. The calculation method of the potential use unit was used to survey the potential of the water resource in the city water system. The amount of theoretical unused energy and energy savings in the model city were estimated using this method. It is estimated that the amounts of energy savings and $CO_2$ reduction correspond to 131.3 GWh and 29280[t-C], respectively, per annual basis.

A BIM-based Design Method for Energy-Efficient Housing (BIM 기반의 저에너지 주거공간 설계 기법 연구)

  • Yoon, Seung-Hyun;Park, Nam-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.187-192
    • /
    • 2009
  • Nowadays, global warming and high oil prices were a threat to the survival of the whole human race. One of a solution to respond to these problems is to reduce energy consumption of building. By adopting energy-saving design, the dissemination of low energy building is required. Therefore, to improve energy efficiency while reducing the usage of the design method is necessary to study actively. BIM-based systems applied to buildings, scheduled to be built by reducing the amount of energy reduction technologies can be analyzed. Depending on various design and equipment to set energy savings goals, you can select an alternative. If it is possible to predict the energy efficiency from the initial stage of design and support designing low energy building, we would be able to expect improvement in the economics of housing due to the reduction of energy consumption.

  • PDF

A Study on Finding Ways to Reduce the Emission of Target Greenhouse Gases for Various Scenarios Utilizing the Building Energy Efficiency Rating (건물에너지 효율등급 제도를 이용한 시나리오별 목표 온실가스 저감방안에 관한 연구)

  • Bang, Young-Hyun;Kang, A-Ram;Park, Hyo-Soon;Suh, Seung-Jik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.89-94
    • /
    • 2012
  • The international community is paying close attention to the climatic changes caused by the meteorological anomalies. In response to such phenomena, after the adoption of the United Nations Framework Convention on Climate Change in 1992, efforts to actively respond to the meteorological changes are proliferating all over the world; even in the Republic of Korea, the issue to tackle the meteorological changes has emerged as a top-priority national agenda. In the year of 2008, after the declaration of the low-carbon, green-growth paradigm by the government, the UNFCCC COP15 has announced a 30% reduction target of the emission of the greenhouse gases by 2020 as compared to the "Business As Usual, BAU" and has also confirmed, as a commitment plan to achieve reduction in the emission of greenhouse gases, the reduction target of greenhouse gases for all sectors, industries and years. (26.9% for buildings) Since the construction of the new apartment houses in the year of 2001, the "Building Energy Efficiency Rating", has been applied to newly constructed building complexes, built in 2010; the accumulated emission reduction has been evaluated at around 450,000toe and the accumulated carbon dioxide emission reduction is at $826,000tCO_2$ And through the prediction of these values under various scenarios (New construction, new construction / expansion of existing uses, when transferred to 1stgrade), the effects on the degree of reduction of greenhouse gases by the increased certification of the Building Energy Efficiency Rating are an alyzed and it is our aim to express the importance of the certification system capable of carrying out a quantitative evaluation of the building energy in order to establish the strategy to reduce the emission of carbon dioxide.

Preparation of Shape-Controlled Palladium Nanoparticles for Electrocatalysts and Their Performance Evaluation for Oxygen Reduction Reaction (연료전지 전극촉매용 팔라듐 나노입자 형상 제어 및 산소환원반응 성능 평가)

  • KIM, KYOUNG-HEE;LEE, JUNG-DON;LEE, HYOJUNE;PARK, SEOK-HEE;YIM, SUNG-DAE;JUNG, NAMGEE;PARK, GU-GON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.450-457
    • /
    • 2018
  • To design the practical core-shell electrocatalysts, combination of core and shell materials is important to meet catalytic activity and durability target. In general, Pd is considered as a good core material due to its best activity caused by strain/ligand effect. Preparing Pd nanoparticles can be a starting point in fabricating core-shell type electrocatalysts, much simplified Pd preparing process is suggested by using carbon monoxide (CO) as a reducing agent and/or capping agent. The solvent composition and reaction temperature can control to nanosheet, tetrahedron, and sphere without using additional stabilizer. Among them, Pd nanosheet which has mainly (111) plane showed about 3 times higher electrocatalytic activity for oxygen reduction reaction (ORR) to the spherical Pd nanoparticles. The enhanced ORR activity of Pd nanosheets can be attributed to the exposure of Pd (111) surface and the high electrochemical surface area. Therefore, we demonstrated that the shape of Pd nanomaterials is easily controlled via a facile reduction method using CO, and (111) plane-oriented Pd nanosheets can be a promising ORR catalysts and core material for polymer electrolyte fuel cells (PEFCs).

Size Reduction Characteristics of Yellow Poplar in a Laboratory Knife Mill

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.166-171
    • /
    • 2016
  • Size reduction is one of the major pre-processing operations in using biomass as a source of energy or raw materials for forest products industry. The grinding characteristics of dried yellow poplar wood chips were investigated using laboratory knife mill with three different screen aperture diameters to provide the basic information for the optimizing of size reduction processes in biomass industry. Average specific energy consumptions were 0.157, 0.137, and 0.093 Wh/g for the screen aperture diameters of 5.0, 7.5, and 9.0 mm, respectively. According to the results of size distribution analysis of ground particles, the sizes of the most of ground particles were much smaller than the aperture diameters of the screens installed on knife mill used in this study.