• Title/Summary/Keyword: Reduction facility

Search Result 616, Processing Time 0.026 seconds

Characteristic Evaluation of Industrial Radiant Tube Burner System with Oscillating Combustion Technology - NOx Reduction and Performance Improvement - (맥동연소기술을 적용한 산업용 복사관 버너시스템의 특성 평가 - NOx 저감 및 성능 향상 -)

  • Oh, Hyuk-Jin;Cho, Han-Chang;Cho, Kil-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.539-545
    • /
    • 2011
  • Combustion characteristics of industrial radiant tube (RT) burners with forced oscillating combustion technology are investigated using a real-scale (125,000 kcal/h) industrial RT burner facility in both laboratory and field tests. Three different types of industrial RT burners using a by-product gas from the iron-and-steelmaking process are examined in a laboratory facility equipped with a W-type RT. During the field tests, an industrial RT burner is characterized in a large facility equipped with multiple RTs. Their performance and emission controls are investigated under diverse operating conditions. The feasibility of the forced oscillating combustion technology is evaluated by the extent of $NO_x$ reduction and the efficiency improvement. These improvements are able to save energy, extend the RT lifetime, and enhance productivity. The operating conditions that achieve the best performance and emission control for each RT burner are determined.

Investigating the Cause of Ash Deposition and Equipment Failure in Wood Chip-Fueled Cogeneration Plant (우드칩을 연료로 하는 열병합발전소의 회분 퇴적 및 설비 고장 원인 분석)

  • Min Ji Song;Woo Cheol Kim;Heesan Kim;Jung-Gu Kim;Soo Yeol Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.187-192
    • /
    • 2023
  • The use of biomass is increasing as a response to the convention on climate change. In Korea, a method applied to replace fossil fuels is using wood chips in a cogeneration plant. To remove air pollutants generated by burning wood chips, a selective denitrification facility (Selective catalytic reduction, SCR) is installed downstream. However, problems such as ash deposition and descaling of the equipment surface have been reported. The cause is thought to be unreacted ammonia slip caused by ammonia ions injected into the reducing agent and metal corrosion caused by an acidic environment. Element analysis confirmed that ash contained alkali metals and sulfur that could cause catalyst poisoning, leading to an increase in the size of ash particle and deposition. Measurement of the size of ash deposited inside the facility confirmed that the size of ash deposited on the catalyst was approximately three times larger than the size of generally formed ash. Therefore, it was concluded that a reduction in pore area of the catalyst by ash deposition on the surface of the catalyst could lead to a problem of increasing differential pressure in a denitrification facility.

Design of Automatic Inspection System for Maintenance of Unmanned Monitoring Facility (무인감시설비 유지보수를 위한 자동점검시스템 설계)

  • Moon, Chaeyoung;Kim, Semin;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.515-517
    • /
    • 2018
  • Access to public facilities such as substations, dams and railway facilities is strictly controlled, and unmanned surveillance equipment has been introduced and operated recently due to the development of IT technology and the government's cost reduction policy. However, if an unmanned surveillance system is broken, surveillance space, information leakage caused by intruders, and damage to facilities may occur. Also, it is necessary to check periodical visit by the manager in order to check the surveillance facilities, which causes additional management costs. In order to solve this problem, we designed a system to check the operation status of the unmanned monitoring facility in real time, attempt to recover automatically when a problem occurs, and notify the administrator of the problem. The designed system consists of an NVR that receives and judges information such as image, sound, and lighting condition, and a control device that detects and restores the state of the unmanned monitoring facility. The system proposed in this paper is expected to contribute to the improvement of the economic efficiency due to the minimization of surveillance space due to the failure of the unmanned monitoring facility and the reduction of the inspection cost.

  • PDF

Evaluation of Water Cycle Improvement in LH Institute Using SWMM-LID Model (SWMM-LID 모델을 이용한 토지주택연구원의 물순환 개선효과 평가)

  • Jung, Jong-Suk;Jung, Kwang-Wook;Kang, Suman;Hyun, Kyong-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.308-315
    • /
    • 2018
  • SWMM-LID was calibrated with flow monitoring data in LHI to evaluate runoff after LID application. The flow rate in the B basin was estimated to be 0.94 and 6.15 for O/S and $D_v$, respectively. In the A and C basins, the difference between the observed and simulated data was greater than in the B basin. As a result of runoff reduction efficiency by the application of LID facilities, the change of infiltration increased from 34.6 % to 45.8 % in the entire watershed, and the runoff decreased from 58.8 % to 46.3 %. In the runoff reduction of each LID facility, rain garden E showed the highest effect with 99.9 % and bioretention B showed the lowest effect with 27.5 %. In order to evaluate the efficiency of each LID facility, a comparison is made between the pore volume (V) of the LID and the catchment area (A). The runoff showed a runoff reduction effect of about 70 % above the 0.1 volume/area (V/A) value. As a result of examining the runoff reduction with LID facilities by the LID module of SWMM, a reasonable design is possible by reflecting the appropriate LID volume to drainage area.

A Study on the Workplace Noise Environment of Office Areas in Power Plant (발전소 관리실의 작업환경 소음에 관한 연구)

  • 김병삼
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

Development of Web-based Light Facility Control Management System (Web기반 조명시설 제어 관리 시스템의 개발)

  • Chang, Byong-Kun;Jeon, Chang-Dae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.182-189
    • /
    • 2005
  • In this paper, A web-based server system was developed based on PDA(Personal Digital Assistants) for controlling and managing light facilities on-line with wireless communication efficiently. The control box of current light facilities may be implemented based on simple operational function. The operational quality of the light facilities will be efficiently improved with some practical advantages such as reduction of required facility, manpower and time in managing the lights and control boxes by using the popular PDA.

BIM-based Property Management by Linking Maintenance with Financial Data for Commercial Building Projects

  • Shin, Hyeonju;Cha, Heesung
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.418-425
    • /
    • 2022
  • For a commercial building, property managers play an important role in maximizing the benefit by reducing cost and increasing revenue in the operation and maintenance phase of the building. However, most of property managers are spending their time in monitoring facility managers who have little impact on cost reduction and maximization of operating profit. The industry practitioners have difficutlty in increasing the efficiency of thier work due to this work environment. In addition, both property managers(PMr) and facility managers(FMr) are dependent on the paper drawings and manuals, which can worsen the inefficiency and human errors are inevitable. This study aims to contribute to improvement of the current practice by developing a novel algorithm that autmatically links the facility information with 3D model, which can provide an efficient property management for commercial buildings.

  • PDF

Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility

  • Mi Sung Jo;Hoi Pin Kim;Boo Wook Kim;Richard C. Pleus;Elaine M. Faustman;Il Je Yu
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.114-117
    • /
    • 2024
  • A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire.We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (㎛). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

Shielding design and analyses of the cold neutron guide hall for the KIPT neutron source facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.989-995
    • /
    • 2018
  • Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.

A Case Study of Spatial Composition of Elderly Skilled Nursing Facility - Focused on 5 facilities of Jeonbuk Province of Korea - (노인 전문요양시설의 공간구성에 관한 연구 - 전라북도 소재 5개 시설을 중심으로 -)

  • 이민아;유옥순
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The purpose of this study was to analyze spatial composition of elderly skilled nursing facility and to provide basic information for setting up the detail facility architectural guidelines. The results of the study were following: the residential spaces of the facilities in this study were more or less overcrowded since their capacity were more than 5 elderly residents. The dimensions of some residential spaces did not even come up to the standard of elderly welfare law in force. On the other hand, the facilities had a tendency to use a space with multiple purposes or to allocate a space but to leave it with no use. Moreover comparing with the 1st floor, which was mainly for the staffs and had enough space to spare, the upper floor which was for the elderly residents, was crowded with nursing staffs and elderly residents and had densely closed residential and public spaces. For the problem solving, law and regulation modification is needed according to the case study about the usage and using frequency of each facility space. And the crowded area for the elderly residents could be enlarged through the reduction(or combination) of the rarely used spaces and moving a few residential spaces into the 1st floor.