• Title/Summary/Keyword: Reduction Rate Test

Search Result 812, Processing Time 0.029 seconds

The Evaluation of Fracture Toughness for Woven Carbon Fibered Reinforced Composite Materials (평직 탄소섬유강화 복합재료의 파괴인성평가)

  • Park, Hong-Sun;Lee, Woo-Hyung;Keum, Jin-Hwa;Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.69-76
    • /
    • 2010
  • This study examined how the fracture toughness is affected according to the variation of the initial crack length and the fiber arranged angle using FEA method and experimental method. Therefore, the energy release rates were calculated and compared by J-integral method and VCCT(Virtual Crack Closure Technique). The results of fracture toughness test verified these results. At this time, the locus method was used in order to determine the energy release rate. When the results of FEA were compared with those of experiment, all of those decreased with the increase of angle between load and the fiber arranged direction. The decrease was due to reducing maximum load and stiffness, and the reason of reduction has been judged that the inplane shear stress.

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

The Effect on the Combustion and Emission Characteristics of HCNG Engine According to the High Purity Hydrogen Contents (고순도 수소함량에 따른 HCNG 연소특성 및 배출가스 영향 평가)

  • Lee, Jong-Tae;Lim, Yun-Sung;Kim, Hyung-Jun;Lee, Seong-Wook;Lee, Jang-Hoon;Kim, Jong-Geu
    • Journal of ILASS-Korea
    • /
    • v.17 no.3
    • /
    • pp.152-157
    • /
    • 2012
  • This investigation decribes the effect of the combustion and emission characteristics of HCNG engine according to the high purity hydrogen contents. The HCNG fuel was made by the mixture with a high purity hydrogen ($H_2$) and a natural gas. The test vehicle was applied to the bi-fuel (Gasoline and CNG) system and this system was modified from the fuel supply and fuel tank. In addition, the three premixed HCNG fuels with mixed rate of 10, 20 and 30% of hydrogen were used to maintain the safety. In order to analyze the combustion characteristics of HCNG and CNG, the fuel was injected in the combustor with constant volume. The exhaust emission from light duty vehicle with bi-fuel system was analyzed by a chassis dynamometer and emission analyzer. From these results, the reduction rate of NOx emission increased in the HCNG fuel and emission amount of THC and CO shows a similar level with CNG fuel. This study can be utilized the basic data for the development of a new business plans related with HCNG engines.

The Cooking Efficiency and Qualities of Deodeok-gui from Optimized Pre-processing of Codonpsis lanceolata (더덕 전처리 방법에 따른 조리 작업 효율 및 더덕구이의 품질 특성)

  • Shin, Myung-Eun;Cho, Mi-Na;Kim, Yong-Sik;Lee, Kyung-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.22 no.6
    • /
    • pp.860-867
    • /
    • 2012
  • Codonopsis lanceolata serves as, an appetizing health food for its, characteristic flavor, taste, and texture:however, it requires a long and complicated cooking process. Therefore, this study conducted pre-processing procedures to improve the cooking process and Codonopsis lanceolata more easily. For processing efficiency, freezing and blanching were efficient for peeling and the rate of peel disuse. In addition the freezing process, effectively reduced the time spent in beating raw material. In the salinity test, freezing and blanching quickly increased salinity over 28 days. As the result of SEM cross-section tests showed that frozen Codonopsis lanceolata become porous, it's assumed that seasoning permeates into this cross-section efficiently. As the appearance of Deodeok-gui as significant differences according to the pre-processing methods, this study examined pre-processing methods(time spent in peeling, rate of peel disuse, time spent in beating out material, salinity, moisture content, texture, and the color) of Codonopsis lanceolata. After testing Deodeok-gui, it was found that freezing is effective, not only for process efficiency and cooking time reduction, but also for improving its qualities.

Engineering Properties of Concrete Using Recycled Aggregate Manufactured by Bar-Crusher (봉파쇄기에 의해 제조된 재생굵은골재를 사용한 콘크리트의 공학적 특성)

  • Baek, Dae-Hyun;Han, Dong-Yeob;Yu, Myoung-Youl;Lee, Gun-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.83-86
    • /
    • 2006
  • This study investigates engineering properties of concrete using recycled coarse aggregated manufactured by bar-crusher. Test showed that Bar-crusher(S) had more effective results at fresh state than cone-crusher(C) and impact-crusher(I). In case of specimens manufactured by S, increase of spindle velocity, incorporating ratio of recycled aggregate and maximum size of aggregate inclined fluidity. As for the hardened concrete, compressive strength of specimens by C or I exhibited lower value than that of S. In addition, specimens using recycled aggregate manufactured by 400rpm and 500rpm of spindle velocity showed less than 10% reduction rate of strength, which is not significant reducing value. It is found that 500rpm of the spindle velocity had the best strength performance, while 600rpm was the worst. Strength value of specimens decreased as incorporating ratio of recycled aggregate inclined, but the strength value of most specimens exhibited less than 10% of reducing rate, assuming favorable result, only at less than 25% incorporating ratio of recycled aggregate.

  • PDF

Lower cellular metabolic power can be an explanation for obesity trend in Tae-Eum type: hypothesis and clinical observation

  • Shim, Eun Bo;Leem, Chae Hun;Kim, Joong Jae;Kim, Jong Yeol
    • Integrative Medicine Research
    • /
    • v.6 no.3
    • /
    • pp.254-259
    • /
    • 2017
  • Background: Those classified as Tae-Eum (TE)-type people in Sasang constitutional medicine (SCM) are prone to obesity. Although extensive clinical observations have confirmed this tendency, the underlying physiological mechanisms are unknown. Here, we propose a novel hypothesis using integrative physiology to explain this phenomenon. Methods: Hypoactive lung function in the TE type indicates that respiration is attenuated at the cellular level - specifically, mitochondrial oxygen consumption. Because a functional reduction in cellular energy metabolism is suggestive of intrinsic hypoactivity in the consumption (or production) of metabolic energy, we reasoned that this tendency can readily cause weight gain via an increase in anabolism. Thus, this relationship can be derived from the graph of cellular metabolic power plotted against body weight. We analyzed the clinical data of 548 individuals to test this hypothesis. Results: The statistical analysis revealed that the cellular metabolic rate was lower in TEtype individuals and that their percentage of obesity (body mass index >25) was significantly higher compared to other constitutional groups. Conclusion: Lower cellular metabolic power can be an explanation for the obesity trend in TE type people.

Assessment of flow-accelerated corrosion-induced wall thinning in SA106 pipes with elbow sections

  • Seongin Moon;Jong Yeon Lee;Kyung-Mo Kim;Soon-Woo Han;Gyeong-Geun Lee;Wan-Young Maeng;Sebeom Oh;Dong-Jin Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1244-1249
    • /
    • 2024
  • A combination of flow-accelerated corrosion (FAC) tests and corresponding computational fluid dynamics (CFD) tests were performed to determine the hydrodynamic parameters that could help predict the highly susceptible location to FAC in the elbow section. The accelerated FAC tests were performed on a specimen containing elbow sections fabricated using commercial 2-inch carbon steel pipe. The tests were conducted at flow rates of 9 m/s under the following conditions: water temperature of 150 ℃, dissolved oxygen <5 ppb, and pH 7. Thickness reduction of the specimen pipe due to FAC was measured using ultrasonic testing. CFD was conducted on the FAC test specimen, and the turbulence intensity, and shear stress were analyzed. Notably, the location of the maximum hydrodynamic parameters, that is, the wall shear stress and turbulent intensity, is also the same location with maximum FAC rate. Therefore, the shear stress and turbulence intensity can be used as hydrodynamic parameters that help predict the FAC-induced wall-thinning rate. The results provide a method to identify locations susceptible to FAC and can be useful for determining inspection priority in piping systems.

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Inactivation of Escherichia coli, Saccharomyces cerevisiae, and Lactobacillus brevis in Low-fat Milk by Pulsed Electric Field Treatment: A Pilot-scale Study

  • Lee, Gun Joon;Han, Bok Kung;Choi, Hyuk Joon;Kang, Shin Ho;Baick, Seung Chun;Lee, Dong-Un
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.800-806
    • /
    • 2015
  • We investigated the effects of a pulsed electric field (PEF) treatment on microbial inactivation and the physical properties of low-fat milk. Milk inoculated with Escherichia coli, Saccharomyces cerevisiae, or Lactobacillus brevis was supplied to a pilot-scale PEF treatment system at a flow rate of 30 L/h. Pulses with an electric field strength of 10 kV/cm and a pulse width of 30 µs were applied to the milk with total pulse energies of 50-250 kJ/L achieved by varying the pulse frequency. The inactivation curves of the test microorganisms were biphasic with an initial lag phase (or shoulder) followed by a phase of rapid inactivation. PEF treatments with a total pulse energy of 200 kJ/L resulted in a 4.5-log reduction in E. coli, a 4.4-log reduction in L. brevis, and a 6.0-log reduction in S. cerevisiae. Total pulse energies of 200 and 250 kJ/L resulted in greater than 5-log reductions in microbial counts in stored PEF-treated milk, and the growth of surviving microorganisms was slow during storage for 15 d at 4℃. PEF treatment did not change milk physical properties such as pH, color, or particle-size distribution (p<0.05). These results indicate that a relatively low electric-field strength of 10 kV/cm can be used to pasteurize low-fat milk.

An Experimental Study on Reduction of $CO_2$ Exhausted Emission by using Fuel-cut Function of Vehicles (고속도로 주행 시 연료차단 기능을 활용한 $CO_2$ 배출량 감축에 대한 실험적 연구)

  • Ko, Kwang-Ho;Jeong, Seung-Hyun;Yoo, In-Kyoon;Lee, Soo-Hyung;Kim, Je-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The fuel is not injected when the driver doesn't push acceleration pedal of a vehicle with engine speed higher than about 1,500rpm above mid vehicle speed range. This is called "fuel-cut function" and almost every modern vehicle is equipped with this function. This is activated on downhill part of a highway most often. Therefore the vehicle-exhausted $CO_2$ can be zero in this downhill part if the driver could recognize this part of highway. We compared the vehicle-exhausted $CO_2$ emission when using fuel-cut function with the $CO_2$ mass when without using this function in this study. We found that the $CO_2$ emission reduced with fuel-cut function and measured the reduction rate of vehicle-exhausted $CO_2$ mass with this test results. The exhausted $CO_2$ mass of a passenger car(2,000cc engine volume) is reduced by 4% with this function used. This $CO_2$ reduction effect can be achieved if the downhill part of a highway is painted with a specific color. And this road painting can be included in the highway road rehabilitation policy.