PAM 인버터를 이용한 무효전력보상장치의 고조파 저감에 관한 연구 (A Study on The Reducing Harmonics of Static Var Compensator using PAM Inverter)

  • 박현철;김영민;황종선;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1103-1106
    • /
    • 2002
  • This paper presents SVC which use PAM method and eliminate harmonics. Inverter is connected directly so that SVC improve output voltage waveform into 24 steps. Inverter output waveform THD is reduced to 6.89%. Leading control of reactive power generated in power system is possible. Snubber is added to reduce switching loss.

  • PDF

전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.35-42
    • /
    • 2006
  • 규모가 큰 제철소는 전기로를 포함한 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생 시키고, 전력 계통의 전압을 왜곡시킨다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 고조파 저감을 위해 수용가 모선에 동조 필터 적용과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가를 심도 있게 분석한다. 고조파 해석 프로그램인 EDSA는 사례연구에 시뮬레이션 도구로 사용되었다.

오차의 허용범위를 고려한 수동형 필터의 특성 해석 (Performance Analysis for Passive Filter Considering Allowable Limits of Tolerance)

  • 김종겸;김일증
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.38-43
    • /
    • 2009
  • Reactors are connected with capacitors to passive filter circuits for reducing harmonics caused by power conversion application. This passive filter frequently gets out of order by voltage and current stress. Especially filter reactor has too much voltage harmonics components, its trouble rate is higher than capacitor. In this paper, we analyzed voltage and current of reactor and capacitor used for passive filter by simulation and measurement. If reactor has a tolerance on variation of reactance value, series resonance frequency is different from originally filter design frequency and parallel resonance can be generated at the close point of the former. Because filter absorbs harmonic component of non-linear load, much of harmonic voltage has been impacted on reactor.

새로운 고조파 저감형 고역율 단상정류 회로 (A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit)

  • 김칠용;문상필;조만철;서기영;권순걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

2분할 전류유입 공진 회로를 이용한 PFC회로의 설계 (Design of the Circuit for a Power Factor Correction using the Two-Input Current Resonant)

  • 장우신;고강훈;서기영;이현우;곽동걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.233-235
    • /
    • 2001
  • On the active filter converter for power factor correction is used inverter for a air-conditioner's power supply to meet IEC standard In the active filter topology for power factor correction, extra switch only control the input current indirectly to satisfied with the IEC standard for reducing the cost and size. In this paper, by dividing the input current into two different modes, the current conduction period can be widened and harmonics can largely be canceled between the two modes. Hence, the harmonics characteristics can be significantly improved, whereby the lower order harmonics, such as the fifth and seventh orders, are much reduced. The results are confirmed by theoretical and experimental implementations.

  • PDF

Control of Grid-Connected Inverters Using Adaptive Repetitive and Proportional Resonant Schemes

  • Abusara, Mohammad A.;Sharkh, Suleiman M.;Zanchetta, Pericle
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.518-529
    • /
    • 2015
  • Repetitive and proportional-resonant controllers can effectively reject grid harmonics in grid-connected inverters because of their high gains at the fundamental frequency and the corresponding harmonics. However, the performances of these controllers can seriously deteriorate if the grid frequency deviates from its nominal value. Non-ideal proportional-resonant controllers provide better immunity to variations in grid frequency by widening resonant peaks at the expense of reducing the gains of the peaks, which reduces the effectiveness of the controller. This paper proposes a repetitive control scheme for grid-connected inverters that can track changes in grid frequencies and keep resonant peaks lined up with grid frequency harmonics. The proposed controller is implemented using a digital signal processor. Simulation and practical results are presented to demonstrate the controller capabilities. Results show that the performance of the proposed controller is superior to that of a proportional-resonant controller.

전해조 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electrolyzer Loads)

  • 김경철;진성은;이주홍;서범관;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.12-20
    • /
    • 2006
  • 중화학 공업은 전해조를 포함한 비선형 부하를 가지고 있다. AC-DC 컨버터로 구성된 전해조는 고조파 전류를 발생시키고, 전력 계통의 전압을 왜곡 시킨다. 본 논문에서는 전해조 부하의 고조파 현장 측정, 고조파 저감을 위해 수용가 모선에 동조 필터 적용과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE 519에 의한 고조파 평가를 심도있게 분석한다. 고조파 해석 프로그램인 EDSA는 사례연구에 시뮬레이션 도구로 사용되었다.

전력회사의 스타콘 투입시 과도 전압 상승과 고조파 분석에 관한 연구 (A Study on the Analysis of Transient Overvoltages and Harmonics due to Utility STATCON Switching)

  • 김경철;서범관;송영주;이일무
    • 조명전기설비학회논문지
    • /
    • 제17권5호
    • /
    • pp.51-59
    • /
    • 2003
  • 전력회사와 수용가들은 유도성 부하에 무효전력을 공급하여 역률(수용가)이나 전압(전력회사)을 조절하기 위해 커패시터 뱅크(전력회사는 스타콘이라 함)를 설치 운영하고 있다. 본 논문에서는 전력회사의 스타콘 투입시 발생되는 과도 전압 상승과 고조파를 분석하고자 한다. 과도 전압과 고조파를 저감시키는 간단한 수단중의 하나는 수용가의 커패시터 뱅크를 전력회사의 스타콘을 투입한 후에 과도상태가 지난뒤에 투입하는 방법이다. EDSA프로그램으로 컴퓨터 시뮬레이션을 수행하여 수용가에서의 과도 전압 상승과 고조파 저감 효과를 검증 하였다. 그리고 수용가에서 발생하는 고조파를 잘 알려진 국제 고조파 관리 기준인 IEEE 519와 IEC 1000으로 비교해 보았다.

배전계통에서 수동필터를 이용한 고조파 저감에 관한 연구 (A Study of Reducing Harmonics using Passive Filter in Distribution System)

  • 푸준;박건우;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.547-548
    • /
    • 2007
  • Recently, harmonic distortion becomes a very important problem of power quality in distribution system. This paper discusses the procedure of passive filter design, and presents the harmonic study of reducing harmonic distortion in distribution system using passive filters.

  • PDF

보조전원장치에 의한 12-펄스정류기의 고조파 저감 (A harmonic reduction scheme for 12-pulse diode rectifiers by auxiliary voltage supply)

  • 김성환;김종수;오세진;윤경국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.916-922
    • /
    • 2014
  • 본 논문에서는 12-펄스정류기의 고조파 저감을 위해 12-펄스정류기의 커패시터 중앙 DC버스에 보조전원장치의 설치를 제안하였다. 그리고 이 장치에 의해 고조파가 감소되는 이론적인 배경을 다루었으며 부하전류의 크기에 따라 보조전원장치가 어떻게 제어되어야 하는지를 밝혔다. 본 논문에서 제안한 보조전원장치는 구형파 전압원을 적용함으로써 능동필터와 같은 다른 방식에 비해 시스템 구조가 간단하고 보다 저렴하다. 본 논문에서 제안하는 12-펄스정류기 고조파 저감법의 검증을 위해 소프트웨어 PSIM을 활용하였으며 제안된 방식의 유효성을 확인하였다.