• 제목/요약/키워드: Reducing Building Energy

Search Result 249, Processing Time 0.027 seconds

Enhancing the Seismic Performance of Multi-storey Buildings with a Modular Tied Braced Frame System with Added Energy Dissipating Devices

  • Tremblay, R.;Chen, L.;Tirca, L.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • The tied braced frame (TBF) system was developed to achieve uniform seismic inelastic demand along the height of multi-storey eccentrically braced steel frames. A modular tied braced frame (M-TBF) configuration has been recently proposed to reach the same objective while reducing the large axial force demand imposed on the vertical tie members connecting the link beams together in TBFs. M-TBFs may however experience variations in storey drifts at levels where the ties have been removed to form the modules. In this paper, the possibility of reducing the discontinuity in displacement response of a 16-storey M-TBF structure by introducing energy dissipating (ED) devices between the modules is examined. Two M-TBF configurations are investigated: an M-TBF with two 8-storey modules and an M-TBF with four 4-storey modules. Three types of ED devices are studied: friction dampers (FD), buckling restrained bracing (BRB) members and self-centering energy dissipative (SCED) members. The ED devices were sized such that no additional force demand was imposed on the discontinuous tie members. Nonlinear response history analysis showed that all three ED systems can be used to reduce discontinuities in storey drifts of M-TBFs. The BRB members experienced the smallest peak deformations whereas minimum residual deformations were obtained with the SCED devices.

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

A Fundamental Study on the Construction Scenario for Prediction of Carbon Emissions in Construction Site (건설현장 시공과정의 탄소배출량 예측 시나리오 구축에 관한 연구)

  • Lee, Chung-Won;Lim, Hyo-Jin;Tae, Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.247-248
    • /
    • 2023
  • As carbon neutrality becomes an issue around the world, research is actively being conducted to achieve reduction targets for each industry by declaring 2050 carbon neutrality in Korea and implementing the greenhouse gas target management system and emission trading system. The construction industry quantitatively predicts and evaluates carbon emissions by stages through the evaluation of the entire building process, but research on this is insufficient in the case of the construction process. Therefore, as part of the research on predicting and reducing carbon emissions generated at construction sites, data from actual construction sites were collected to analyze the facilities and characteristics of each energy source, and a scenario was proposed to quantitatively predict the use of each energy source.

  • PDF

Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading (창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석)

  • Choi, Changdae;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions (창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구)

  • Choi, Min-Seo;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

Sustainable Buildings - or Sustainable Cities?

  • Schwettmann, Mark
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.2
    • /
    • pp.103-107
    • /
    • 2015
  • China's rapidly growing cities offer a unique opportunity to create highly sustainable communities. Architects and their clients, typically real estate developers, are highly focused on strategies that are effective at reducing energy and water usage at the scale of the individual building or within a master plan of multiple related buildings. However, a closer look at energy consumption reveals that transportation uses more energy worldwide than residential and commercial buildings combined. In light of this, it is appropriate that China is making massive investments in transportation infrastructure like heavy rail rapid transit and grade separated expressways, but the end result of these investments to date has been to enable people to live further from where they work and shop rather than closer - while simultaneously not creating walkable communities. Using positive and negative examples from Asia and the rest of the world, this article will investigate the specific urban design policies such as height limits, setbacks, land use restrictions, parking ratios, and parcel size which might change to enable the creation of truly sustainable communities for China's 21st century.

Comparison on the Energy Performance of Underfloor Air Distribution System According to Modeling Method Using EnergyPlus (EnergyPlus를 이용한 바닥공조시스템의 모델링 방법에 따른 에너지 성능 비교)

  • Jang, Hyang-In;Yoon, Seong-Hoon;Lee, Hyun-Soo;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.718-723
    • /
    • 2012
  • The purpose of this study is to propose modeling method of Underfloor Air Distribution System with reliability and validity by comparing characteristics of modeling methods. For this, the modeling methods of UFAD were selected by investigating various modeling methods of previous researches. Then, simulations were conducted by using EnergyPlus which is dynamic analysis program of building energy. Annual energy consumption for each method was compared with a wide range of indoor thermal loads. As a result, the methodology of reducing internal gains can cause under sizing of the system. It suggests modeling methods to reflect occupied zone air-conditioning, temperature stratification and supply plenum which are the main characteristics of UFAD.

Preparation and Thermal Performance Evaluation of Heat Storage paint with MPCM for Reducing Urban Heat Island Effect (도시 열섬현상 저감을 위한 MPCM 적용 축열도료 제조 및 열적성능 평가)

  • Jeong, Su-Gwang;Kang, Yujin;Wi, Seunghwan;Chang, Seong Jin;Kim, Sumin
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.17-24
    • /
    • 2015
  • The formation of heat islands causes high energy demand for space cooling and peak cooling loads in conditioned buildings. High-temperature fluctuations on a building roof may cause mechanical stress and increase surface deterioration. Thermal energy storage (TES) systems using microencapsulated phase-change materials (MPCMs) have been recognized as one of the most advanced energy technologies for enhancing the energy efficiency and sustainability of buildings. In this study, we prepared MPCM/paint composites for mitigating the heat island effect and reducing peak temperature. In addition, we carried out thermal and physical analysis of prepared MPCM composite samples by means of SEM, FTIR spectroscopy, DSC, and TGA. Further, we evaluated the dynamic heat transfer performance of heat-storage tiles painted with 10 g of heat-storage paint. From the obtained results, we deduced that MPCM/hydrophilic paint composites are more applicable to various fields, including the building sector, than MPCM/hydrophobic paint composites. On the basis of SEM and FTIR spectroscopy results, we concluded that materials with hydrophilic properties are more compatible with MPCMs than those with hydrophobic properties. In addition, DSC analysis results revealed that MPCM/hydrophilic paint composites have better compatibility, higher latent heat capacity, and better thermal properties than other composites. TGA results showed that hydrophilic-paint-based composites have higher thermal durability than hydrophobic-paint-based composites. Finally, a lot of MPCM-loaded heat-storage tiles showed lower peak temperatures at all measurement positions.

Strength Properties of Multi-layered Insulation according to the Type of Configuration (다층형 단열재의 구성 형식에 따른 강도 특성 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF