• Title/Summary/Keyword: Reducing Building Energy

Search Result 249, Processing Time 0.024 seconds

A Study on the Method about the Economic Feasibility Estimation Considering Renewable Energy (신재생에너지원을 고려한 집단에너지 경제성평가 방법론에 관한 연구)

  • Shin, Hye-Kyeong;Choi, Young-Jun;Choi, In-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.372-374
    • /
    • 2008
  • Korea classified into a development country when UNFCCC was concluded in 1995. So Korea doesn't have a GHG reduction duty until 2012. As the UNFCCC is strengthened, recently there is a growing interest in renewable energy and energy usage efficiency improvement for reducing GHG emission. It is associated with CES and renewable energy. CES is a total energy (heat, cooling and power)supplier in aggregated demand zone like a hotel, building, hospital and redevelopment district using CHP and it improves energy usage efficiency. At present, renewable energy is needed for GHG reduction duty but renewable energy doesn't have economic feasibility. So renewable energy is needed various support system to popularize which is a FIT and RPS. Especially RPS is carrying out instead of FIT in many advanced country and it will be inroduced in Korea. RPS is a duty which electricity service provider must guarantee renewable energy as much as specific ratio of total capacity. Therefore this study conducts an economic feasibility estimation of CES considering renewable energy when RPS will introduced in the future.

  • PDF

Development of an End-use Analysis Tool for Existing Buildings Based on Energy Billing Data (고지데이터 기반 기존 건축물의 용도별 에너지사용 현황분석 툴 개발)

  • Kong, Dong-Seok;Park, Jung-Min;Jang, Yong-Sung;Lee, Keon-Ho;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.128-136
    • /
    • 2015
  • Reducing the building energy consumption has become one of the most important issues. However, the current engineering and technological involvement in energy analysis has been relatively low in the existing buildings. In the existing buildings, end-use analysis must be accompanied to calculate the exact amount in energy savings and such analysis should be conducted based on the energy billing data or measurement data by calibration process. Mostly, detailed energy simulation programs have been proposed for the analysis but, it is difficult to utilize them due to realistic problems. In this paper, we developed an end-use analysis tool that have input function for energy audit data and two case studies were conducted in the real-life office buildings located in Seoul, Korea. Mean Bias Error (MBE) and Coefficient of Variation of Root-Mean- Squreaed-Error (CV(RMSE)) are used for the criteria of comparison. Each index was calculated by using monthly utility bills of electricity and gas consumption. Results showed that MBE and CV (RMSE) represented with acceptable values of -0.1% and 5.7% respectively.

Analysis of Ventilation Impact in Multi-Family Residential Building Utilizing TOPSIS Method (다기준 의사결정방법을 이용한 공동주택 내 환기장치 종류별 효과분석)

  • Park, Kyung-Yong;Kim, Gil-Tae;Kim, Tae-Min;Ji, Won-Gil;Kwag, Byung-Chang
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.107-113
    • /
    • 2022
  • With increasing airtight building construction aimed at reducing energy consumption, indoor relative humidity is increasing which can lead to condensation and moisture damage in multi-family residential buildings. This has led to increased implementation of mechanical ventilation to control indoor moisture. However mechanical ventilation systems consume additional energy and generate noise. As this leads to occupant discomfort, it is necessary to select a ventilation system that addresses the energy and noise issues. This research measured the ventilation performance, energy consumption, and noise level of mechanical ventilation devices in multi-family residential buildings. TOPSIS, a multi-criteria decision making technique was used to determine appropriate ventilation strategies in addition to occupant ventilation system operation preference.

A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Ju-Young;Kim, Yu-Lan;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

Energy Load according to the Units of Apartment House (공동주택 세대 위치에 따른 에너지 부하량)

  • Kim, Sung-Hoon;Lee, Jun-Gi;Kim, Yong-Tae;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.78-83
    • /
    • 2015
  • In Korea, multi-housing in one of the most common types of residential space due to its easy management and convenience. In particular, south-facing plate-type(一) multi-housing has attracted a great deal of public interest because it consumes less energy compared with other types of multi-housing, making it advantageous from an energy-saving perspective. Although there have been many studies on the annual energy consumption of multi-housing in relation to building shape and area of window, there have not been sufficient research on the annual energy consumption of multi-housing in relation to individual units of the multi-housing. The purpose of this study is to propose a strategy for reducing energy consumption in plate-type(一) multi-housing, taking the units with the lowest energy consumption as the standard. The result, Standard Models's energy load was as 4000 ~ 5600kWh, and Passive Houses's energy load was less than Stand Models at the 1600kWh.

Improving Assessment of External Environment for Green Standard for Energy & Environmental Design Certification according to Climate Change (기후변화에 따른 녹색건축인증제도의 외부환경 평가항목 개선방향 연구)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Song, Ok-Hee
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.171-180
    • /
    • 2017
  • In 1990s, as the extreme weather events according to the global warming climate change are occurred frequently all around the world and the scale of the damage increases, the developed countries are promoting various policies for reducing greenhouse gas emissions setting the goal of greenhouse gas reduction with the level of State and local government. Especially for the greenhouse gas reduction of buildings and the inducement of eco-friendly design, the green certification system is strengthened with the assessment of energy and greenhouse management, and recently, according to the policy change of climate and energy, the certification system expanded from the buildings to the level of city and district is piloted. So this research is to understand the main contents and the assessment system of domestic green building certification system implemented in March 2013 in response to the policy change of climate and energy and to suggest the basic data for the improvement of present domestic greenhouse certification standard through the analysis of actual certification and the main case analysis of international green certification system. Recently in developed countries, in 1990s, for the reduction of building's greenhouse gas emission and the inducement of eco-friendly design, from the building of LEED, BREEAM, DGNB to the level of city and district such as LEED Neighborhood Development, BREEAM Communities, DGNB Stadtquartiere, the system is expanded and piloted. On the contrary, as for the domestic standard of green building certification system, the distribution ratio according to the assessment items in each category consists of the assessment system based on the buildings, and just the simple adjustment of some items and the improvement of weighted value are performed. Actually, as a result of selecting the 30 districts of apartment housing with the most certification performance by use among the 49 buildings certified by Institute of Land & Housing from December 2014 to July 2016 and analyzing the assessment score, the certification level is determined by the sectors of high distribution like indoor environment and energy not by the ineffective sector of external environment with low distribution so this system has a limitation to perform the practical means for the policy change of climate and energy. Thus for the national green building certification standards, the assessment system in the sector of external environment is to complemented and furthermore, reflecting domestic reality, through the introduction of certification system and the assessment system with the level of city and district, this system should be improved to meet the international certification standard.

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

A Comparative Study on Domestic and International Evaluation Criteria of Commissioning for Sustainable Building Certification (국내외 녹색건축인증에서의 커미셔닝 평가기준에 대한 비교 연구)

  • Jeong, Dahun;Jung, Chanwoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • Ministry of Land, Infrastructure and Transport established Heating and cooling energy conservation plan of apartment for 2017, reducing 90% compared to energy consumption of 1990. Also, at 2015 United Nations Climate Change Conference, the Ministry announced to reduce 37% of estimated $CO^2$ emission(850 million ton) at 2030. To satisfy this, it is urgent to reduce $CO^2$ emission due to the building, which takes majority amount of total $CO^2$ emission, and public interest for the commissioning of intensified building performance is uprising. However, the building commissioning at construction is not enacted, and not activated due to the lackness of promotion and will of general contractor. Furthermore, commissioning is not mandatory for obtaining G-SEED certification. Therefore, this paper describes effectiveness of commissioning with comparison of commissioning evaluation criteria of G-SEED with LEED and BREEAM, to propose making commissioning as mandatory process and drive changes in perception among stakeholders for activation of domestic building commissioning.

A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System (바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.

Assessment of The Luminance Distribution from Daylighting window by Using Image Processing Methodology (이미지 프로세싱 기법을 활용한 채광창의 휘도분포 평가)

  • Park, Jong Myung;Lim, Hong Soo;Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • Daylighting is the controlled admission of natural light into a space, reducing electric lighting and saving energy. By providing a direct link to the dynamic and perpetually evolving patterns of outdoor illumination, daylighting helps create a visually stimulating and comfort environment for building occupants, while reducing energy costs. Especially, however, glare is the most important factor in daylighting, which is issued by incoming direct sunlight into windows. This study analyzed the discomfort glare on a daylighting window by using Image processing methodology and found a solution to problems with glare source of occupants. There are several ways to evaluate discomfort glare such as UGR (Unified Glare Rating) of CIE, DGI (Daylight Glare Index, Hopkinson, 1972) and VCP (Visual Comfort Probability) of IES. These are used to apply to the relatively little artificial light source and they cannot cover discomfort glare from a real daylighting window. In this regarding, this paper aimed to calculate DGI index of the real daylighting window in a experimental space by using image processing methodology. The variables and outcomes are luminance distribution of non-shading window, effect of venetian blind installed on the window and locations related to position index of DGI.