Background: This study was aim to identify the specific words and to develop the scale for the public health center (PHC) image. Methods: We collected 824 words from the previous studies and by open questions and reduced them by 77 words, then which were rated properly by 355 citizens of Seoul. We examined explanatory factor analysis for 69 words, and examined content validity test and confirmatory factor analysis (CFA) for the image structures (4 factors and 16 words). And then we developed the image questionnaire using them through council. We conducted a survey and retested the PHC image scales as the measuring tool targeting 2,000 persons, and compared the inexperience and experience persons for PHC usage. Results: The image structures were consisted of 4 factors and 16 words such as 'trustworthiness' (warm, exemplary, faithful, service-mindedness, beneficial to health), 'fairness' (honesty, clear, consistent, ruled), 'development possibility' (changing, goal-directed, developmental, propulsive), and 'flexibility' (not authoritative, not perfunctory, not rigid) in total. Cronbach's ${\alpha}$ values of all factors were above 0.7. As a result of CFA, model fit indexes yielded satisfactory results (root mean square error of approximation [RMSEA] 0.049, goodness of fit index [GFI] 0.937, and adjusted goodness of fit index [AGFI] 0.912). According to the result of retest for measuring tool by using other samples, Cronbach's ${\alpha}$ values were above 0.8, and model fit indexes yielded satisfactory results (RMSEA 0.059, GFI 0.952, AGFI 0.933). RMSEAs of the inexperiences and the experiences were each 0.59, 0.68. Conclusion: A reliable, valid, and generalizable scale was created for PHC image.
A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.
To set the similarity conditions between a prototype usually in the field and its reduced-scale model is a crucial part in model tests. No technique is available to keep perfect similarity for this procedure so far. The experimental work using a wind tunnel is not exceptional. based on the field measurements, the effect of stack parameters and wind conditions on the dispersion of stack plume has been investigated in the laboratory. in this paper intensive methodology is focused on matching these similarities. Due to the limitations to keep perfect similarity conditions some simplifications are involved in common. In this study geometric conditions and kinematic conditions using Froude number and Reynolds number have been con-sidered to keep the similarity conditions required. From the tests it is found that the critical Reynolds number (Recrit) is 2,700 when the height of stack discharge is 50mm. The dispersion has a similar trend for the higher Reynolds number than the critical Reynolds number. It is also found that different Froude number does not make any significant influence for the normalized tracer gas concentrations at the recipient providing the same ratio of the wind speed to the discharge speed. No significant effect of stack diameter is observed in the normalized tracer gas concentrations with the same Frounde number. The similarity conditions therefore used in this study are reliable to simulate the conditions in prototype into the wind tunnel tests.
Objectives The purpose of this study is to reduce the question items in Korea Sasang Constitutional Diagnostic Questionnaire (KS-15) and to assess the validity. Methods The subjects of this study were 1,553 people who had information on body shape, personality, and symptoms among the data established at the Korean Medicine Data Center. Among them, 155 people were separated into a test group to assess the validity, and the remaining 1,398 were used as training groups for model development. The reduction question items were finally confirmed through discussion by two experts. The model development went through Multinomial Logistic Regression. Results & Conclusions The Percent Correctly Predicted (PCP) in the test group was 60.00% (58.49% in men and 60.78% in women). The PCP of each constitution was 72.6% in Taeeumin, 53.3% in Soeumin, and 50% in Soyangin. The accuracy rate of KS-10 seems to be reasonable considering the ease of use of reduced time required.
우리나라 전통 초가삼간의 1/4 축소모델을 제작하여 암반지반 조건에 대한 내진성능실험을 수행하였다. Nahanni 지진파를 사용하여 최대 가속도 0.1g~0.6g 범위에서 거동을 분석하였다. 탄성한계에서 초가삼간의 고유진동수는 장방향의 경우 약 1.66Hz, 단방향의 경우 215Hz이다. 탄성한계에서의 감쇠비는 약 7%이다. 수평방향의 가속도응답은 입력에 비해 감소하며 입력가속도 수준이 증가할수록 감소율이 증가한다. 이는 사개맞춤으로 만들어진 목조 프레임의 비선형.비탄성 특성 때문이다. 전통 초가삼간 가옥은 고진동수가 지배적인 암반지반에서 매우 큰 내진성능을 나타내었다.
RC (Reinforced Concrete) members are always subjected to loading conditions and have construction joints when constructed on a big scale. Service life for RC structure exposed to chloride attack is usually estimated through chloride diffusion test in sound concrete, however the test is performed without consideration of effect of loading and joint. In the present work, chloride diffusion coefficient is measured in concrete cured for 1 year. In order to evaluate the effect of applied load, cold joint, and mineral admixtures, OPC (Ordinary Portland Cement) and 40%-replaced GGBFS (Ground Granulated Blast Furnace Slag) concrete are prepared. The diffusion test is performed under loading conditions for concrete containing cold joint. Investigating the previous test results for 91 days-cured condition and the present work, changing diffusion coefficients with applied stress are normalized considering material type and cold joint. For evaluation of service life in RC continuous beam with 2 spans, non-linear analytical model is adopted, and service life in each location is evaluated considering the effects of applied stress, cold joint, and GGBFS. From the work, varying service life is simulated under various loading conditions, and the reduced results due to cold joint and tensile zone are quantitatively evaluated. The effect of various conditions on diffusion can provide more quantitative evaluation of chloride behavior and the related service life.
The sandwich panel is commonly used domestically because it's less costly and easier to handle. But fires have frequently occurred in buildings employing sandwich panels, such as the fires in Eecheon cold storage and in Gwangju Pyungdong industrial zone. Sandwich panels with steel plates on their surface prevent fire water from penetrating to the fire source, which makes it difficult to extinguish a fire in a timely manner. Toxic gas generated from some insulation material leads to serious loss of life and property. This study is intended to develop an extinguishing system for sandwich panels, thereby reducing the fire risk. Fire water and volume were determined in the wake of the study on the structure of a sandwich panel extinguishing system, and improvement and testing of the fire characteristics of the sandwich panel. Based on such study and test, a fire model test was conducted. Consequently, the sandwich panel with extinguishing system was proven to have a reduced fire risk, compared to traditional or fire retardant panels.
본 논문에서는 기초지반의 강성이 블록식 보강토 옹벽의 거동에 미치는 영향에 대한 내용을 다루었다. 기초지반의 강성이 블록식 보강토 옹벽의 거동에 미치는 근본적인 메카니즘을 고찰하기 위해 보강토 옹벽에 대한 축소모형실험을 수행하였으며 축소모형실험 결과의 타당성을 검토하고 모형실험에서 다룰 수 없었던 다양한 조건을 고려함과 아울러서 현장옹벽 응력수준의 거동을 고찰하기 위해 가상의 현장옹벽에 대해 유한요소해석을 이용한 매개변수 연구를 수행하였다. 모형실험 및 유한요소해석 결과에 의하면 기초지반의 강성이 감소할수록 벽체의 변위는 현저히 증가하며, 이러한 벽체변위 증가 현상은 보강토체 내부변형보다는 보강토체의 강체 거동으로 인해 야기되는 메카니즘을 보이는 것으로 나타나 기초지반에 관련된 문제를 외적안정성의 개념에서 다루고 있는 현 설계기준은 타당한 것으로 나타났다. 본 논문에서는 모형실험 및 유한요소해석 결과를 종합하여 실무적 측면에서의 중요성을 다각적으로 고찰하였다.
큰 선행하중을 가할 수 있는 새로운 선행하중 시스템을 개발하였으며, 이를 적용하여 근접굴착 시 기존 터널의 안정성을 확보하는 방안을 연구하였다. 흙막이 벽체의 수평변위가 거의 생기지 않도록 설계축력 이상의 선행하중을 가하였다. 이를 위해 선행하중을 가하지 않는 경우와 선행하중을 가하는 경우에 대해 축소율 1/10인 실 대형 시험을 실시하였다. 수치해석은 선행하중을 가하지 않는 경우와, 선행하중을 설계축력의 50%와 100%를 가하는 경우, 흙막이 벽체 변위를 거의 발생시키지 않는 크기의 선행하중을 가하는 경우에 대해 유한요소법(FEM) 프로그램인 PLAXIS를 사용하여 수행하였다. 그 결과 선행하중을 설계축력 이상으로 적용시켜 흙막이 벽체변위를 억제시켰을 때 벽체 배면 지반에 있는 터널의 안정성이 크게 향상되는 것을 확인할 수 있었다.
본 연구진은 최근 U자 형태인 액체댐퍼의 수직관을 다수의 셀(사각 기둥)로 나누어 셀 상부를 개폐함에 따라 다양한 고유진동수를 쉽게 재현하는 새로운 멀티셀 액체댐퍼를 제시하였다. 이러한 댐퍼를 1층 건물 모형에 설치하여 진동대 실험을 수행하여 건물응답이 감소되는 것을 검증하였다. 64층의 풍응답인 가속도를 제어할 수 있도록 댐퍼를 설계하기 위하여 건물을 1자유도계로 축소하였다. 가속도 기반 상사비인 1/20를 적용하여 1층 건물 모형과 새로운 댐퍼를 제작하였다. 설계 진동수인 0.65Hz가 구현되도록 모형건물의 질량과 강성을 쉽게 조절할 수 있도록 탈부착식으로 제작하였다. 모형건물은 중량을 부담하는 질량부와 하부에 스프링과 LM guide가 설치된 구동부로 나누어서 제작되었다. 18개의 셀을 가지는 액체댐퍼를 제작하여 고유진동수 조절 범위가 0.65Hz~0.81Hz인 것을 파악하였다. 대형 진동대에 설치한 모형건물의 일방향 가진을 통하여 모형의 응답을 측정하고 모형상부에 멀티셀 액체댐퍼가 설치되었을 경우 모형의 응답을 측정하여 비교하였다. 진동대 가속도를 입력과 모형건물의 가속도를 출력으로 하는 전달함수를 통해 결과를 나타내었다. 예상한 바와 같이 멀티셀 액체댐퍼의 고유진동수를 건물의 진동수에 동조시켰을 경우 건물의 가속도 응답이 감소함을 알 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.