• Title/Summary/Keyword: Red-shift

Search Result 295, Processing Time 0.033 seconds

The Protective Effect of Orally Ingested Korean Red Ginseng on the Noise Induced Hearing Loss in Mice (마우스에서 고려 홍삼의 구강내 섭취를 통한 소음성 난청의 예방효과)

  • Ahn, Joong-Ho;Kim, Tae-Soo;Chung, Hana;Lee, Na-Young;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • v.33 no.2
    • /
    • pp.104-110
    • /
    • 2009
  • It is well known that the saponin of Korean red ginseng (KRG) has an anti-oxidant effect and could suppress the accumulation of lipid peroxidation. The aim of the present study was to observe the inhibitory effect of KRG on mice with noise-induced hearing loss, and to determine its optimal dose. BALB/c mice with a normal hearing level and normal Preyer's reflexes were used in the study. The mice in the permanent-threshold-shift (PTS) group were exposed to noise (120-dB SPL, white noise band) in a noise booth for 3 h a day, for three consecutive days. The mice in the experimental group were given heat-processed red-ginseng extract (50 mg/kg, 100 mg/kg, and 200 mg/kg), and those in the control group were given normal saline alone during their noise exposure. The mice in the temporary-threshold-shift (TTS) group were exposed to noise (120 dBSPL, white noise band) in a noise booth for 3 h. The mice in the experimental group were given heat-processed red-ginseng extract (50 mg/kg, 100 mg/kg, and 200 mg/kg), and those in the control group were given normal saline alone before their noise exposure. The hearing levels of the mice were measured through auditory brainstem response (ABR) immediately and I, 3, 5, 7, and 14 days after their noise exposure. Cochleae were removed from the mice 14 days after their noise exposure. lmmunochemical and immunofluorescent staining were performed to observe the expression of 8-oxoG in cochlea. In the PTS group, the hearing function of the mice in all the groups was not recovered after their noise exposure. In the TTS group, however, the hearing function of the mice in all the groups was recovered within 14 days. Reduced hearing impairment and early recovery were observed in the mice that were given 200 mg/kg KRG, and early recovery was observed in the mice that were given 100 mg/kg KRG The immunopositive staining of 8-oxoG was detected in the stria vascularis in the control group but was diminished in the mice that were given 200 mg/kg KRG The ingestion of more than 100 mg/kg KRG demonstrated a protection and recovery effect on the noiseinduced-TTS group. Since KRG has been reported to be a safe compound even up to hundreds of mg/kg, a higher concentration of it may effectively protect and recover TTS.

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Magnetic and Electronic Properties of Reduced Rutile Ti1-xMnxO2-δ Thin Films

  • Kim, Kwang-Joo;Park, Young-Ran;Ahn, Geun-Young;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.11 no.1
    • /
    • pp.12-15
    • /
    • 2006
  • Magnetic and electronic properties of reduced rutile titanium dioxide $(TiO_{2-\delta})$ thin films doped by Mn have been investigated. The present sol-gel-grown semiconducting $TiO_{2-\delta}:Mn$ films exhibit a ferromagnetic behavior at room temperature for a limited range of Mn content. The Mn-doped films have p-type electrical conductivity with the carrier concentration near $10^{19}\;cm^{-3}$. The observed room-temperature ferromagnetism is believed to be intrinsic but not related to free carriers such as holes. Oxygen vacancies are likely to contribute to the room-temperature ferromagnetism-trapped carriers in oxygen vacancies can mediate a ferromagnetic coupling between neighboring $Mn^{+3}$ ions. The energy band-gap change due to the Mn doping measured by spectroscopic ellipsometry exhibits a red-shift compared to that of the undoped sample at low Mn content. It is explainable in terms of strong spin-exchange interactions between Mn ion and the carrier.

Enhanced UV-Light Emission in ZnO/ZnS Quantum Dot Nanocrystals (산화아연/황화아연 양자점 나노결정에서의 향상된 자외선 방출)

  • Kim, Ki-Eun;Kim, Woong;Sung, Yun-Mo
    • Korean Journal of Materials Research
    • /
    • v.18 no.12
    • /
    • pp.640-644
    • /
    • 2008
  • ZnO/ZnS core/shell nanocrystals (${\sim}5-7\;nm$ in diameter) with a size close to the quantum confinement regime were successfully synthesized using polyol and thermolysis. X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM) analyses reveal that they exist in a highly crystalline wurtzite structure. The ZnO/ZnS nanocrystals show significantly enhanced UV-light emission (${\sim}384\;nm$) due to effective surface passivation of the ZnO core, whereas the emission of green light (${\sim}550\;nm$) was almost negligible. They also showed slight photoluminescence (PL) red-shift, which is possibly due to further growth of the ZnO core and/or the extension of the electron wave function to the shell. The ZnO/ZnS core/shell nanocrystals demonstrate strong potential for use as low-cost UV-light emitting devices.

Three White Organic Light-emitting Diodes with Blue-green Fluorescent and Red Phosphorescent Dyes

  • Galbadrakha, Ragchaa;Bang, Hwan-Seok;Baek, Heume-Il;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • v.9 no.3
    • /
    • pp.23-27
    • /
    • 2008
  • This paper reports that well-balanced white emission with three primary colors can be achieved with a simple white organic light-emitting diode (WOLED) structure of ITO / $\alpha$-NPD (50 nm) / $\alpha$-NPD: Btp2Ir(acac) (8 wt%, 6 nm) / $\alpha$-NPD (5 nm) / BCP (3 nm) / $Alq_3$: C545T (0.5 wt%, 10 nm) / $Alq_3$ (40 nm) / LiF (0.5 nm) / Al (100 nm). The external quantum efficiency of the device reached 3.8% at a current density (luminance) of 4.6 mA/$cm^2$ (310 cd/$m^2$), and the maximal luminance of the device reached 19,000 cd/$m^2$ at 11.5 V. The insignificant blue shift of the emitting color with an increasing current density can be attributed to the narrowing of the exciton formation zone width.

The Effect of pH-adjusted Gold Colloids on the Formation of Gold Clusters over APTMS-coated Silica Cores

  • Park, Sang-Eun;Park, Min-Yim;Han, Po-Keun;Lee, Sang-Wha
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1341-1345
    • /
    • 2006
  • An electrostatic interaction is responsible for the attachment of gold seeds of 1-3 nm onto APTMS (3-aminopropyl trimethoxysilane)-coated silica cores in the formation of gold clusters. A surface plasmon resonance and morphology of gold clusters were significantly affected by the pH of gold colloids prepared by THPC reducing agent. Gold colloids of alkaline pH induced the heterogeneous deposition of gold seeds onto the silica nanoparticles, probably due to the continuous reduction of residual gold ions during the attachment process. Gold colloids of acidic pH induced the monodisperse deposition of gold seeds, consequently leading to the formation of smooth gold layer on the silica nanoparticles surface. The gold nanoshells (core radius = 80 nm) prepared by gold colloids of pH 3.1 exhibited the more red-shift and relatively stronger intensity of plasmon absorption bands, compared with gold nanoshells prepared by alkaline gold colloids of pH 9.7.

A Triple-Probe Channel NO2S2-Macrocycle: Synthesis, Sensing Characteristics and Crystal Structure of Mercury(II) Nitrate Complex

  • Lee, Ji-Eun;Choi, Kyu-Seong;Seo, Moo-Lyong;Lee, Shim-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.2031-2035
    • /
    • 2010
  • A triple-probe channel type chemosensor based on an $NO_2S_2$-macrocycle functionalized with phenyltricyanovinyl group was synthesized and its sensing characteristics were examined. The pink-red solution of L changed selectively to pale yellow upon addition of $Hg^{2+}$. The selective fluorometric response of L to all the tested metal ions was studied. The results showed that a large enhancement of the fluorescence of L was observed only in the case of $Hg^{2+}$. In addition, L showed large anodic shift (~ 0.3 V) for the addition of excess $Hg^{2+}$. Through above three observed results by the different techniques, we confirmed that the proposed chemosensor acts as the multiple-probe channel sensing material. The crystal structure of mercury(II) nitrate complexs of L which shows a 1-D polymer network with a formula $[Hg_2(L)_2(NO_3)_2({\mu}-NO_3)_2]_n$ was also reported.

Harvesting Productivity and Cost of Clearcut and Partial Cut in Interior British Columbia, Canada

  • Renzie, Chad;Han, Han-Sup
    • Journal of Forest and Environmental Science
    • /
    • v.24 no.1
    • /
    • pp.1-14
    • /
    • 2008
  • Clearcutting has been the dominant harvesting method in British Columbia (representing 95% of the total area harvested annually). However forest managers are increasingly recommending the use of alternative silvicultural systems and harvest methods, including various types of partial cutting, to meet ecological and social objectives. In this study we compared harvesting productivity and harvesting costs between treatments through detailed and shift level time studies in 300-350 year-old Interior Cedar-Hemlock stands in British Columbia, Canada. Recommendations for improving operational planning/layout and the implementation of clearcut and partial cutting silvicultural systems were made. Harvesting costs varied in the ground-based clearcut treatments from $10.95/$m^3$ - $15.96/$m^3$ and $16.09/$m^3$ - $16.93/$m^3$ in the group selection treatments. The ground-based group retention treatment had a cost of $13.39/$m^3$, while the cable clearcut had a cost of $15.70/$m^3$. An understanding of the traditional and alternative wood products that could be derived from the harvested timber was imperative to increasing the amount of merchantable volume and reducing the corresponding harvesting costs. Stand damage was greatest in the group selection treatments; however, mechanized felling showed an increase in stand damage over manual felling while grapple skidding showed a decrease in skidding damage compared to line skidding.

  • PDF

Synthesis and Luminescence of Lu3(Al,Si)5(O,N)12:Ce3+ Phosphors

  • Ahn, Wonsik;Kim, Young Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.463-467
    • /
    • 2016
  • $Si^{4+}-N^{3-}$ was incorporated into $Ce^{3+}-doped$ lutetium aluminum garnet ($Lu_{2.965}Ce_{0.035}Al_5O_{12}$, $LuAG:Ce^{3+}$) lattices, resulting in the formation of $Lu_{2.965}Ce_{0.035}Al_{5-x}Si_xO_{12-x}N_x$ [(Lu,Ce)AG:xSN]. For x = 0-0.25, the synthesized powders consisted of the LuAG single phase, and the lattice constant decreased owing to the smaller $Si^{4+}$ ions. However, for x > 0.25, a small amount of unknown impurity phases was observed, and the lattice constant increased. Under 450 nm excitation, the PL spectrum of $LuAG:Ce^{3+}$ exhibited the green band, peaking at 505 nm. The incorporation of $Si^{4+}-N^{3-}$ into the $Al^{3+}-O^{2-}$ sites of $LuAG:Ce^{3+}$ led to a red-shift of the emission peak wavelength from 505 to 570 nm with increasing x. Corresponding CIE chromaticity coordinates varied from the green to yellow regions. These behaviors were discussed based on the modification of the $5d^1$ split levels and crystal field surroundings of $Ce^{3+}$, which arose from the Ce-(O,N)8 bonds.

Dopant에 따른 amorphous carbon layer의 etch rate 변화 분석연구

  • Jeong, Won-Jun;Kim, Dong-Bin;Park, Sang-Hyeon;Im, Seong-Gyu;Kim, Yong-Seong;Lee, Chang-Hui;Yun, Ju-Yeong;Kim, Tae-Seong;Sin, Jae-Su;Gang, Sang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.92.2-92.2
    • /
    • 2015
  • Negative-AND (NAND) flash의 대용량 및 소형화로 인해 10 nm급 공정을 도입한 128 Gb NAND flash가 개발된 이래, 공정이 미세화되면서 셀이 작이지고 간격이 좁아지게 되었다. 이로 인해 전자가 누설되는 간섭현상이 심화되게 된다. 이러한 문제를 해결하기 위해 기존 NAND의 평면 구조를 수직으로 적층하는 3D NAND 기술이 개발되었으며 차세대 소자를 위한 필수 기술로 각광받고 있다. 3D NAND에서 channel hole etching시 고 선택 비의 중요도가 증가하여 증착막 보호 역할을 하는 hardmask의 두께가 증가하게 되었으며 기존 하드마스크 대비 내식각성이 2배 이상 향상된 hard material 개발이 필요한 실정이다. 본 연구에서는 dopant에 따른 amorphous carbon layer (ACL)의 etch rate의 변화량을 Raman spectroscopy등의 측정장비를 이용하여 비교분석 하였다. dopant의 각각 유량별에 대한 etch rate 변화의 영향성을 비교하였다. dopant의 유량에 따라 etch rate이 변화하는 것을 관찰할 수 있었으며, 2000 sccm 이후에는 etch rate이 급격히 감소하는 경향을 보였다. Raman 측정결과, etch rate의 감소에 따라 G-peak의 red shift가 발생하였으며 두 peak 간의 차이 값이 etch rate의 변화율과 유사한 경향을 보이는 것을 확인하였다.

  • PDF