Surgical Treatment of Metastatic Tumor in Proximal Femur with Recycling Autograft Prosthetic Composite after Wide Excision (근위 대퇴골 전이성 종양의 수술적 치료로서 광범위 절제술 후 재활용 자가골을 이용한 복합 고관절 성형술)

  • Kim, Jae-Do;Park, Pil-Jae;Kwon, Young-Ho;Jang, Jae-Ho;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • Purpose: Due to local recurrence of tumor, metal failure usually develops in patients who underwent internal fixation or hip joint arthroplasty after curettage in the case of metastatic tumor of proximal femur. The aim of this study is to find out the appropriateness of reconstruction using recycling autograft after wide excision in the case of metastatic bone tumor by performing recycling autograft and hip joint arthroplasty after wide excision, and through presence or absence of local recurrence, functions of lower limbs and occurrence of complications. Materials and Methods: Five patients, in 6 cases, who had undergone reconstruction using recycling autograft prosthetic composite after wide excision in the metastatic tumor from May 2000 to May 2003 were included in this study. The average age of the patients was 60.8 years of age with male to female ratio of 3:2. Average duration of lives following surgery was 23.3 month (7-57 months). Primary lesion included 2 cases of lung cancer, and 1 each of stomach cancer, renal cancer and multiple myeloma. After wide excision, the hip joint was reconstructed with recycling autograft prosthetic composite ; 4 cases of extracorporeal irradiation and 2 cases of pasteurization. Musculoskeletal Tumor Society (MSTS) score(1993) for 6-month period after surgery, as well as presence of complication and local recurrence during the rest of their lives, were studied. Results: Average Musculoskeletal Tumor Society (MSTS) score over the 6-month period after surgery was 63.3% and 1 case of dislocation of hip joint, as a complication following surgery, was discovered. Local recurrence during the lives of the patients was not observed. Conclusion: In the case of metastatic tumor of proximal femur, in which the life span following surgery is expected to be more than 6 months, undergoing reconstruction using recycling autograft after wide excision, in comparison to internal fixation or hip joint arthroplasty after curettage, is deemed to have better results in prevention of local recurrence, and preservation of the functions of all limbs during the life span of the patient.

  • PDF

When do we use the Recycling Autograft in Limb Salvage Surgery? (사지구제술에서 언제 재활용 자가골 이식술이 유용한가?)

  • Kim, Jae-Do;Jang, Jae-Ho;Cho, Yool;Kim, Ji-Youn;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2008
  • Purpose: To identify which is the best procedure in recycling autograft according to the resection & reconstruction type and recycling methods, and so when the recycling autograft is used in limb salvage surgery. Materials and Methods: We have treated fifty-eight patients (34 male, 24 female; age range 5 to 74 years, mean age 36.5 years), who had the malignant musculoskeletal tumors, with recycling autograft (47 patients with extracoporeal irradiation, 11 patients with pasteurization) from December 1995 to February 2006. The resection and reconstruction type was 3 cases with fragmentary, 8 intercalary, 23 rAPC (recycling-Autograft-Prosthesis composite), 18 osteoarticular, 5 total joint and 1 soft tissue (achilles tendon). The result was evaluated by the radiologic union at junctional site, the functional score by musculoskeletal tumor society score and complications according to the resection & reconstruction type and recycling methods. Results: The junctional union was obtained at 15.0 months in extracoporeal irradiation and 12.6 months in pasteurization. Also the mean radiologic union was shown at 6.0 months in fragmentary, 12.8 months in intercalary, 10 months in rAPC, 23.3 months in osteoarticular and 15.6 months in total joint. The functional score was 65.5% in fragmentary, 60.8% in intercalary, 62.8% in APC (except pelvis), 66.0% in osteoarticular and 66.6% in total joint. We have experienced 1 infection, 1 prutrusio acetabuli in pasteurization (18.1%) and other 22 complications (3 deep infections, 8 nonunions, 2 fractures, 2 epiphyseal problems, 5 joint instabilities, 2 local recurrence) in extracoporeal irradiation (46.8%). Also we have experienced 3 complications (3 nonunions) in intercalary (37.5%), 9 complications (4 nonunions, 1 deep infection, 1 periprosthetic fracture, 1 epiphyseal problem, 1 local recurrence, 1 protrusio acetabuli) in rAPC (50.0%), 6 complications (2 deep infections, 2 nonunions, 1 epiphyseal problem, 1 pathologic fracture) in osteoarticular (33.3%), 5 complications (5 joint instabilities) in total joint (100%) and 1 complication(1 local recurrence) in soft tissue (100%). Conclusion: In our experience, according to the resection & reconstruction type fragmentary and intercalary may have several advantages such as good radiologic and functional result and low rate of complication. And it seems that rAPC was available in case which have no sufficient residual bone stock. Also the pasteurization may have more advantages than that of the extracorporeal irradiation.

  • PDF

Recycling Total Joint Autotransplantation in Osteosarcoma around the Knee Joint (슬관절 주위 골육종에서 체외 방사선 조사를 이용한 재활용 전 자가 관절 이식술)

  • Chung, So-Hak;Cho, Yool;Kim, Jae-Do
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • Purpose: Recycling extracorporeal irradiated autograft is used as one of the reconstruction methods after limb salvage with malignant bone tumor. However, there were some problems such as joint instability, progressive arthritis, insufficient joint resection margin were found after intraarticular recycling autograft. Thus, we carried out a research in order to investigate the results of recycling total joint autotransplantation after extracorporeal irradiation that could resolve the problems. Materials and Methods: There were five cases of patients who were diagnosed as osteosarcom around the knee joint and underwent same operation from June 1997 to Feb 2006. All patients had been evaluated from 93 to 105 months (mean 100 months) and their mean age was 21.6. Results: The roentgenographic union of junctional sites began at 15.6 months (9~40 months) postoperatively. As regards to the orthopaedic functional results, we used the criteria of Ennecking et al. Overall mean functional result was 71.6%. Complication such as epiphyseal collapse (three cases) and joint instability (five cases) were noted respectively. In all the cases, tumor prosthesis was used to replace the knee joint. Conclusion: Because recycling total joint autotransplantation after extracorporeal irradiation does not prevent joint instability and progressive arthritis, tumor prosthesis is recommended in young adult.

  • PDF

Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length (감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 -)

  • Kwon, Young-Ho;Kim, Jae-Do;Chung, So-Hak;Cho, Yool
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • In 1996, a nine-year-old girl was treated with recycling autograft after wide resection of the distal femoral osteosarcoma. The leg lengthening and revision with growing tumor prosthesis were performed due to limb leg discrepancy and epiphyseal problem. However, deep infection developed after operation, and a temporary spacer with cement and Ender nail was inserted. After infection was controlled completely, the final leg lengthening was performed with mono-external fixator for limb length discrepancy (10 cm). Lastly, Tumor prosthesis was reinserted to preserve the joint function.