• Title/Summary/Keyword: Rectangular Cavity

Search Result 171, Processing Time 0.025 seconds

Design of the Small BPF for Wireless Communication Systems (무선통신용 초소형 대역통과 필터의 설계)

  • Hwang, Jae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.26-31
    • /
    • 2005
  • In this paper, a small BPF(band pass filter) is designed using new probe type for wireless communication system. The dielectric resonator is used high Q ceramics for low loss characteristic. In order to provide a band pass filter which can be reduced in dimension, can be reduced in height, and can be surface-mounted. The filter was fabricated using $TE_{01{\delta}}$ mode dielectric resonator. The input/output probes are attached to coner portion of the rectangular metal cavity. Results of the manufactured filter($12{\times}12{\times}8[mm]$) show that the center frequency is 9.95358[GHz], the insertion loss is -1.9[dB], the 3[dB]_bandwidth is 14.9[MHz], and the loaf Q is 664.

THE ATTITUDE STABILITY ANALYSIS OF A RIGID BODY WITH MULTI-ELASTIC APPENDAGES AND MULTI-LIQUID-FILLED CAVITIES USING THE CHETAEV METHOD

  • Kuang, Jin-Lu;Kim, Byung-Jin;Lee, Hyun-Woo;Sung, Dan-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.1
    • /
    • pp.209-220
    • /
    • 1998
  • The stability problem of steady motion of a rigid body with multi-elastic appendages and multi-liquid-filled cavities, in the presence of no external forces or torque, is considered in this paper. The flexible appendages are modeled as the clamped -free-free-free rectangular plates, or/and as the discrete mass- spring sub-system. The motion of liquid in every single ellipsoidal cavity is modeled as the uniform vortex motion with a finite number of degrees of freedom. Assuming that stationary holonomic constraints imposed on the body allow its rotation about a spatially fixed axis, the equation of motion for such a systematic configuration can be very complex. It consists of a set of ordinary differential equations for the motion of the rigid body, the uniform rotation of the contained liquids, the motion of discrete elastic parts, and a set of partial differential equations for the elastic appendages supplemented by appropriate initial and boundary conditions. In addition, for such a hybrid system, under suitable assumptions, their equations of motion have four types of first integrals, i.e., energy and area, Helmholtz' constancy of liquid - vortexes, and the constant of the Poisson equation of motion. Chetaev's effective method for constructing Liapunov functions in the form of a set of first integrals of the equations of the perturbed motion is employed to investigate the sufficient stability conditions of steady motions of the complete system in the sense of Liapunov, i.e., with respect to the variables determining the motion of the solid body and to some quantities which define integrally the motion of flexible appendages. These sufficient conditions take into account the vortexes of the contained liquids, the vibration of the flexible components, and coupling among the liquid-elasticity solid.

  • PDF

A Study on the Improvement of the Directivity for Rectangular Microstrip Patch Array Antennas Conformed to a Cylindrical Surface (원통면에 정합-배열된 장방형 마이크로스트립 패치 안테나의 지향성 개선을 위한 연구)

  • 고광태;구연건
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.2
    • /
    • pp.46-54
    • /
    • 1994
  • In this paper, an analysis and design method is proposed, which is to improve the directivity of microstrip array antennas conformed to a cylindrical surface. In the case of forming an arc-array in the circumferential direction on a circula-cylinder surface, the circular-cylinder can be approximated to a polygonal-pillar and on each pillar-planes the sub-arrays, Dolph-Tschebyscheff array and uniform array with a beam steered in the desired direction, would make a sharp directivity for the total cylin- drical array antenna. And the radiation pattern according to the type of its sub arrays is analyzed and compared using the cylindrical-cavity codel. A cylindrical microstrip array antenna, with 12 elements and uniform arra as a sub-array which have an equal distance$\lambda_0$/2between the elements, is manufactured and conformed to a cylinder with radius of 6 The measured data of side lobe level, HPBW and FNBW are - 13dB, $9^{\circ}$, and $15{\circ}$, ,respectively. This result shows a good improvement on the directivity comparing with a linear array.

  • PDF

Development of A Electromagnetic Exposure System for In Vitro Experiments at PCS Band (PCS 대역 세포실험용 전자파 노출 장치 개발)

  • Part Min-Young;Ko Chae-Ok;Sung Mi-Jin;Kim Jeong-Lan;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.335-340
    • /
    • 2006
  • In this paper, a rectangular-cavity-type exposure system for in vitro experiments has been developed fur the biological effect studies of radio frequency fields from handhold wireless telephones. It ia fed with a ${\lambda}_g/8$ monopole antennas at the ${\lambda}_g/4$ position of the top plate in order to excite fundamental $TE_{102}$ mode and it allows the uniform exposure of one 8.5 cm(inner diameter) petri dish. SARs inside the exposed medium have been characterized by numerical simulations, using the FDTD method and by experimental dosimetry with fiberoptic temperature probes (model 790, Luxtron Corp.).

Anatomical Studies on the Skeleton of Thoracic Limb of Korean Native Goat (한국재래산양의 전지골격에 관한 해부학적 연구)

  • Kim, Jin-sang;Lee, Heung-shik S.;Lee, In-se
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.167-183
    • /
    • 1987
  • The anatomical structure of the Skeleton of thoracic limb of thirty-one adult Korean native goats(body weight: 14~17kg) was observed after skeletal preparation, and the osteometry was performed in each bone. The results were as follows; 1. The thoracic limb of the Korean native goat was composed of scapula, humerus, radius, ulna, carpal bones, metacarpal bones, phalanges and sesamoid bones. 2. The scapula was flat and triangular in shape. There were no distinct tuber of spine and acromion in the spine. The subscapular fossa was deep and triangular in shape and the vertebral border was sigmoid form. The coracoid bone was formed as the coracoid process at the medial aspect of the supraglenoid tubercle but the clavicle wa.s not observed. The left and right scapular indexes were 57.92 and 58.31 and the glenoid cavity indexes were 89.23 and 86.82, respectively. 3. The greater tubercle of the humerus was devided into cranial and caudal parts. The third tubercle was observed and the face for the infraspinatus muscle was rectangular form. The left and right humerus indexes were 32.44 and 32.63, the head indexes were 94.13, 96.62 and the trochlear-epidondyle indexes were 67.32 and 65.81, respectively. 4. The radius and ulna were fused entirely except at the broad proximal and narrow distal interosseous spaces. The ulna was longer than the radius, and its reduced body and distal end were fused at the caudomedial surface of the radius. 5. The carpal bones were six in number. There were radial, intermediate, ulnar, accessory, second-third and fourth carpal hones in carpal bones. 6. The metacarpal bone was composed of a large metacarpal bone resulted from the fusion of the third and fourth metacarpal bones, and there was a metacarpal tubercle at the dorsolateral part of the proximal end. There were no vestiges of the second and fifth metacarpal bones. 7. The digits were composed of third and fourth digits and each digit was composed of the proximal, middle and distal phalanges. 8. The sesamoid bones were six in number. There were two at the fetlock joint and one at the coffine joint palmarly in each digit. 9. The ratios of the lengths among the scapula, humerus, antebrachium and metacarpal bone were 1.42 : 1.47 : 1.77 : 1.00 in the left and 1.42 : 1.45 : 1.77 : 1.00 in the right, respectively.

  • PDF

EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE (저출력 레이저조사가 동통반응에 미치는 영향)

  • Kim, Sung-Kyo;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF

The effect of irradiated cancellous human bone on exophytic bone formation in residual ridge of the beagle dog (방사선 조사 망상골이 외방형 골형성에 미치는 영향)

  • Chung, Mi-Hyun;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.791-803
    • /
    • 2007
  • The purpose of this study was to evaluate exophytically vertical bone formation in residual ridge of the beagle dog by the concept of guided bone regeneration with a titanium reinforced e-PTFE membrane combined with irradiated cancellous human bone. Twelve male beagle dogs(mean age 1.5 years and mean weight 12kg) were used for this study. The alveolar ridges after extraction of all mandibular premolars were surgically and horizontally removed. At 8 weeks after extractions, full-thickness flap was reflected and cortical bone was removed with round bur and copious irrigation. Rectangular parallelepiped(10mm in length, 5mm in width, and 4mm in height) bended with titanium-reinforced e-PTFE(TR e-PTFE) membrane was placed on the decorticated alveolar ridge, fixed with metal pins and covered with full-thickness flap and assigned as a control group. Test groups ere treated with TR e-PTFE membrane filled with irradiated cancellous human bone. Of twelve beagle dogs, four control dogs and four test dogs without membrane exposure to oral cavity were sacrificed at 8 and 16 weeks respectively. The surgical sites were dissected out, fixed in 4% buffered formaldehyde, dyed using a Villanueva staining technique, and processed for embedding in plastic resin. The cutting and grinding methods were routinely processed for histologic and histomophometric analyis of exophytic bone formation as well as statistical analysis. The results of this study were as follows: 1. Exophytic bone formation in the both of experimental groups was increased respectively after surgery from 23.40% at 8 weeks to 46.26% at 16 weeks in the control groups, from 40.23% at 8 weeks to 47.11% at 16 weeks in the test groups(p<0.05). 2. At 8 weeks after surgery, exophytic bone formation was made 40.23% in the test groups and 33.40% in the control groups. Exophytic bone formation was significantly made in the test group more than in the control group. At 16 weeks after surgery, exophytic bone formation was made 44.11% in the test groups and 46.26% in the control groups. Exophytic bone formation was made in the test groups more than in the control groups, but there was no statistically significant differences. 3. The membrane was fixed with metal pins to closely contact it to the bone surface. So, collapse and deviation of the membrane could be prevented and in growth of connective tissue also could be blocked from the periphery of the membrane. On the basis of these findings, wee suggest that intraoral experimental model for exophytic bone formation may be effective to evaluate the effect of bone graft material. And it indicates that combined use of membrane and ICB graft material is more effective than use of membrane only for exophytic bone formation.

Reconstruction of Congenital Absence of Vagina using Vulvoperineal Fasciocutaneous Flap: A Case Report (외음회음 근막피부피판을 이용한 선천성 질결여증의 재건례)

  • Kim, Mi-Sun;Kim, Chul-Han;Lee, Yong-Sek;Kang, Sang-Gue;Tark, Min-Sung
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.831-834
    • /
    • 2010
  • Purpose: Congenital absence of the vagina is a rare case. It occurs as a result of Mullerian duct aplasia or complete androgen insensitivity syndrome. The reconstructive modality includes skin graft, use of intestine and various methods of flap. We report a patient who underwent vulvoperineal fasciocutaneous flap to reconstruct congenital absence of the vagina, while the external genitalia and ovaries are normal. Methods: A 26-year-old woman presented with vaginal agenesis. Under general anesthesia, a U-shaped incision was made between the urethral meatus and the anus. The new vaginal pocket was created up to the level of the peritoneal reflection between the urinary structures and the rectum. Next, the vulvoperineal fasciocutaneous flaps were designed in a rectangular fashion. Flap elevation was begun at the lateral margin which the adductor longus fascia was incised and elevated, and the superficial perineal neurovascular pedicle was invested by the fascial layer. The medial border was then elevated. A subcutaneous tunnel was created beneath the inferior of the labia to rotate the flaps. The left vulvoperineal flap was rotated counterclockwise and the right was rotated clockwise. The neovaginal pouch was formed by approximating the medial and lateral borders. The tubed neovagina was then transposed into the cavity. Results: In 3 weeks, the vaginal canal remained supple After 6 weeks, the physical examination showed normalappearing labia majora and perineum with an adequate vaginal depth. A year after the operation, the patient had a 7 cm vagina of sufficient width with no evidence of contractures nor fibrous scar formation. The patient was sexually active without difficulty. Conclusion: Although many methods were described for reconstruction of vaginal absence, there is not a method yet to be approved as a perfect solution. We used the vulvoperineal fasciocutaneous flap to reconstruct a neovagina. This method had a following merits: a single-stage procedure, excellent flap reliability, the potential for normal function, minimal donor site morbidity and no need for subsequent dilatation, stents, or obturators. We thought that this operation has a good anatomic and functional results for reconstruction of the vagina.

Evaluation of Physical Properties of Resin Containing Zinc Nanoparticle. (아연나노입자함유 교정용 레진의 물리적 특성 평가)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.373-379
    • /
    • 2019
  • Polymethyl methacrylate (PMMA), a self-polymerizing resin for removable orthodontic devices, has been used as a dental orthodontic device for many years because of its advantages such as color stability, volume stability, and tissue compatibility. However, such a removable orthodontic device has a disadvantage that the longer the use in the oral cavity due to the low strength of the PMMA fracture of the orthodontic device resin in use. In this study, zinc nanoparticles (ZNP) were mixed with orthodontic PMMA to introduce strength effect. Rectangular samples ($1.4{\times}3.0{\times}19.0mm$) of orthodontic PMMA (0, 0.5, 1.0, 2.0 and 4.0%) containing ZNP were prepared. The finished specimen was tested for three-point bending strength at a speed of 1 mm / min, and the Vickers hardness was measured three times using a hardness tester. The surface roughness was measured with a surface roughness. As a result, the 3-point bending strength did not change significantly (p>0.05). Surface energy increased significantly. As a result, we successfully synthesized ZNP in this study and prepared the dispersed resin specimen for calibration. It will be possible to develop high-density dental orthodontic resins.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF